Single-breath clinical imaging of hyperpolarized (129)Xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1-point Dixon acquisition.

Abstract:

PURPOSE:We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathic pulmonary fibrosis (IPF). METHODS:A calibration scan determined the echo time at which (129)Xe in RBCs and barrier were 90° out of phase. At this TE, interleaved dissolved and gas-phase images were acquired using a 3D radial acquisition and were reconstructed separately using the NUFFT algorithm. The dissolved-phase image was phase-shifted to cast RBC and barrier signal into the real and imaginary channels such that the image-derived RBC:barrier ratio matched that from spectroscopy. The RBC and barrier images were further corrected for regional field inhomogeneity using a phase map created from the gas-phase (129)Xe image. RESULTS:Healthy volunteers exhibited largely uniform (129)Xe-barrier and (129)Xe-RBC images. By contrast, (129)Xe-RBC images in IPF subjects exhibited significant signal voids. These voids correlated qualitatively with regions of fibrosis visible on CT. CONCLUSIONS:This study illustrates the feasibility of acquiring single-breath, 3D isotropic images of (129)Xe in the airspaces, barrier, and RBCs using a 1-point Dixon 3D radial acquisition.

journal_name

Magn Reson Med

authors

Kaushik SS,Robertson SH,Freeman MS,He M,Kelly KT,Roos JE,Rackley CR,Foster WM,McAdams HP,Driehuys B

doi

10.1002/mrm.25675

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

1434-43

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

75

pub_type

杂志文章
  • Simultaneous multi-site EPR spectroscopy in vivo.

    abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300210

    authors: Smirnov AI,Norby SW,Clarkson RB,Walczak T,Swartz HM

    更新日期:1993-08-01 00:00:00

  • Bulk volume susceptibility difference between deoxyhemoglobin and oxyhemoglobin for HbA and HbS: A comparative study.

    abstract:PURPOSE:Sickle cell anemia is a blood disorder that alters the morphology and the oxygen affinity of the red blood cells. Cerebral oxygen extraction fraction measurements using quantitative BOLD contrast have been used for assessing inadequate oxygen delivery and the subsequent risk of ischemic stroke in sickle cell an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28668

    authors: Eldeniz C,Binkley MM,Fields M,Guilliams K,Ragan DK,Chen Y,Lee JM,Ford AL,An H

    更新日期:2021-01-21 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

    abstract::T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE method...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21215

    authors: Kellman P,Aletras AH,Mancini C,McVeigh ER,Arai AE

    更新日期:2007-05-01 00:00:00

  • Robust motion correction in CEST imaging exploiting low-rank approximation of the z-spectrum.

    abstract:PURPOSE:To introduce and evaluate an image registration technique for robust quantification of CEST acquisitions corrupted by motion. METHODS:The proposed iterative algorithm exploits a low-rank approximation of the z-spectrum (LRAZ), to gradually separate the contrast variation due to saturation at different off-reso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27206

    authors: Wech T,Köstler H

    更新日期:2018-11-01 00:00:00

  • Lateral geniculate activations can be detected using intersubject averaging and fMRI.

    abstract::Applications of fMRI in functional brain imaging are mainly confined to single subject designs, prohibiting the assessment of subject or group by condition interactions (i.e., differential activations) or areas of conjoint activation. In this paper a framework for fMRI group designs, using statistical parametric mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380502

    authors: Büchel C,Turner R,Friston K

    更新日期:1997-11-01 00:00:00

  • High-resolution contrast-enhanced MRI of atherosclerosis with digital cardiac and respiratory gating in mice.

    abstract::Atherosclerosis initially develops predominantly at the aortic root and carotid origin, where effective visualization in mice requires efficient cardiac and respiratory gating. The present study sought to first compare the high-resolution MRI gating performance of two digital gating strategies using: 1) separate cardi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21308

    authors: Alsaid H,Sabbah M,Bendahmane Z,Fokapu O,Felblinger J,Desbleds-Mansard C,Corot C,Briguet A,Crémillieux Y,Canet-Soulas E

    更新日期:2007-12-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • Detection and volume determination of colonic tumors in Min mice by magnetic resonance micro-imaging.

    abstract::We applied MRI to the in vivo detection of spontaneous colorectal tumors in a unique mouse model, the Fox Chase Cancer Center (FCCC) ApcMIN mouse. Unlike other Min (multiple intestinal neoplasia) strains, FCCC ApcMIN animals develop an appreciable number of tumors in the large intestine, which makes them an appropriat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20175

    authors: Hensley HH,Chang WC,Clapper ML

    更新日期:2004-09-01 00:00:00

  • Performance evaluation of whole-body NMR scanner antenna systems.

    abstract::Whole-body NMR imaging antennas (probes) are strongly affected by the inevitable magnetic and controllable dielectric losses. Using a convenient parallelepiped model, the magnetic losses are evaluated. By introducing the "ideal power gain," the best possible antenna performance is delimited as a function of the freque...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020403

    authors: Sergiadis G

    更新日期:1985-08-01 00:00:00

  • MRI-based transfer function determination through the transfer matrix by jointly fitting the incident and scattered B 1 + field.

    abstract:PURPOSE:A purely experimental method for MRI-based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27974

    authors: Tokaya JP,Raaijmakers AJE,Luijten PR,Sbrizzi A,van den Berg CAT

    更新日期:2020-03-01 00:00:00

  • A one-step biomarker quantification methodology for DCE-MRI of adnexal masses: Capturing kinetic pattern from early to late enhancement.

    abstract:PURPOSE:To develop a one-step quantification approach that accounts for joint preprocessing and quantification of whole-range kinetics (early and late-phase washout) of dynamic contrast-enhanced (DCE) MRI of indeterminate adnexal masses. METHODS:Preoperative DCE-MRI of 43 (24 benign, 19 malignant) sonographically inde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26743

    authors: Fathi Kazerooni A,Nabil M,Haghighat Khah H,Parviz S,Gity M,Saligheh Rad H

    更新日期:2018-02-01 00:00:00

  • PRESTO-SENSE: an ultrafast whole-brain fMRI technique.

    abstract::A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co

    authors: Golay X,Pruessmann KP,Weiger M,Crelier GR,Folkers PJ,Kollias SS,Boesiger P

    更新日期:2000-06-01 00:00:00

  • Inferring multiple maxima in intravoxel white matter fiber distribution.

    abstract::A new methodology is introduced that characterizes the intravoxel orientation distribution function (ODF) based on a single-fiber model of the diffusion MRI signal. Using a Bayesian framework the probability of finding a fiber in a specific orientation is obtained. The proposed ODF estimation relies on a cigar-like di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21673

    authors: Canales-Rodríguez EJ,Melie-García L,Iturria-Medina Y,Martínez-Montes E,Alemán-Gómez Y,Lin CP

    更新日期:2008-09-01 00:00:00

  • Cationized ferritin as a magnetic resonance imaging probe to detect microstructural changes in a rat model of non-alcoholic steatohepatitis.

    abstract:PURPOSE:The goal of this work was to detect disease-related microstructural changes to the liver using magnetic resonance imaging. Chronic liver disease can cause microstructural changes in the liver that reduce plasma access to the perisinusoidal space--the site of exchange between the blood plasma and the hepatic par...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24619

    authors: Beeman SC,Mandarino LJ,Georges JF,Bennett KM

    更新日期:2013-12-01 00:00:00

  • In vivo MRI of fresh stored osteochondral allograft transplantation with delayed gadolinium-enhanced MRI of cartilage: protocol considerations and recommendations.

    abstract::The protocol for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) was adapted for the evaluation of transplanted osteochondral allograft cartilage. Eight patients with focal grade 4 cartilage defects of the femoral condyle were treated with single cylindrical osteochondral allografts. At 1 and 2 years, dGEMRIC i...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24419

    authors: Durkan MG,Szumowski J,Brown DS,Foss EW,Crawford DC

    更新日期:2013-06-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRI.

    abstract::Diffusion-weighted MRI is a clinically useful technique, but its utility is compromised by high sensitivity to patient motion. Use of radial-scan data acquisition and projection reconstruction, rather than the conventional Fourier imaging method, can substantially reduce the sensitivity to global translational motion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290619

    authors: Gmitro AF,Alexander AL

    更新日期:1993-06-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00

  • Visualization of free radical reactions in an aqueous sample irradiated by 290 MeV carbon beam.

    abstract::The detection of free radical reactions in a gelatin sample irradiated by a heavy-ion beam was tested using electron paramagnetic resonance (EPR) spectroscopic and MRI methods. Geometry and the amount of free radical generation in a sample are described. A reaction mixture containing glutathione and a nitroxyl radical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21958

    authors: Matsumoto K,Nagata K,Yamamoto H,Endo K,Anzai K,Aoki I

    更新日期:2009-05-01 00:00:00

  • Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    abstract:PURPOSE:Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25074

    authors: Sharif B,Dharmakumar R,Arsanjani R,Thomson L,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-12-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Sliding time of flight: sliding time of flight MR angiography using a dynamic image reconstruction method.

    abstract:PURPOSE:To obtain three-dimensional (3D) MR angiography having high contrast between vessel and stationary background tissue, a novel technique called sliding time of flight (TOF) is proposed. METHODS:The proposed method relies on the property that flow-related enhancement (FRE) is maximized at the blood-entering slic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25215

    authors: Choi J,Seo H,Lim Y,Han Y,Park H

    更新日期:2015-03-01 00:00:00

  • Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

    abstract:PURPOSE:To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS:A metric based on patient-specifi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25366

    authors: Weavers PT,Borisch EA,Riederer SJ

    更新日期:2015-06-01 00:00:00

  • REKINDLE: robust extraction of kurtosis INDices with linear estimation.

    abstract:PURPOSE:Recent literature shows that diffusion tensor properties can be estimated more accurately with diffusion kurtosis imaging (DKI) than with diffusion tensor imaging (DTI). Furthermore, the additional non-Gaussian diffusion features from DKI can be sensitive markers for tissue characterization. Despite these benef...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25165

    authors: Tax CM,Otte WM,Viergever MA,Dijkhuizen RM,Leemans A

    更新日期:2015-02-01 00:00:00

  • Voxelwise analysis of simultaneously acquired and spatially correlated 18 F-fluorodeoxyglucose (FDG)-PET and intravoxel incoherent motion metrics in breast cancer.

    abstract:PURPOSE:Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26505

    authors: Ostenson J,Pujara AC,Mikheev A,Moy L,Kim SG,Melsaether AN,Jhaveri K,Adams S,Faul D,Glielmi C,Geppert C,Feiweier T,Jackson K,Cho GY,Boada FE,Sigmund EE

    更新日期:2017-09-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • Measurement of perfusion and permeability from dynamic contrast-enhanced MRI in normal and pathological vertebral bone marrow.

    abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22415

    authors: Biffar A,Sourbron S,Schmidt G,Ingrisch M,Dietrich O,Reiser MF,Baur-Melnyk A

    更新日期:2010-07-01 00:00:00

  • Accelerated J-resolved 1 H-MRSI with limited and sparse sampling of ( k , t 1 , t 2 -space.

    abstract:PURPOSE:To accelerate the acquisition of J-resolved proton magnetic resonance spectroscopic imaging (1 H-MRSI) data for high-resolution mapping of brain metabolites and neurotransmitters. METHODS:The proposed method used a subspace model to represent multidimensional spatiospectral functions, which significantly reduc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28413

    authors: Tang L,Zhao Y,Li Y,Guo R,Clifford B,El Fakhri G,Ma C,Liang ZP,Luo J

    更新日期:2021-01-01 00:00:00