The impact of the relaxivity definition on the quantitative measurement of glycosaminoglycans in cartilage by the MRI dGEMRIC method.

Abstract:

:The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the milk solution. Using the R-value at 20% solid component (approximately the solid concentration in bovine nasal cartilage), the glycosaminoglycan concentration in bovine nasal cartilage can be quantified using the MRI delayed gadolinium-enhanced MRI of cartilage method without the customary scaling factor of 2. This finding is also supported by the measurements using 23Na NMR spectroscopy, 23Na inductively coupled plasma analysis, and biochemical assay. The choice of the R-value definition in the MRI delayed gadolinium-enhanced MRI of cartilage method is discussed, and the definition of Gd(DTPA)2- ions as "millimole per volume of tissue (or milk solution for substitution)" should be used.

journal_name

Magn Reson Med

authors

Zheng S,Xia Y

doi

10.1002/mrm.22169

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

25-32

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

63

pub_type

杂志文章
  • Results for diffusion-weighted imaging with a fourth-channel gradient insert.

    abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22971

    authors: Feldman RE,Scholl TJ,Alford JK,Handler WB,Harris CT,Chronik BA

    更新日期:2011-12-01 00:00:00

  • A molecular MRI probe to detect treatment of cardiac apoptosis in vivo.

    abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22876

    authors: Dash R,Chung J,Chan T,Yamada M,Barral J,Nishimura D,Yang PC,Simpson PC

    更新日期:2011-10-01 00:00:00

  • High-resolution contrast-enhanced MRI of atherosclerosis with digital cardiac and respiratory gating in mice.

    abstract::Atherosclerosis initially develops predominantly at the aortic root and carotid origin, where effective visualization in mice requires efficient cardiac and respiratory gating. The present study sought to first compare the high-resolution MRI gating performance of two digital gating strategies using: 1) separate cardi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21308

    authors: Alsaid H,Sabbah M,Bendahmane Z,Fokapu O,Felblinger J,Desbleds-Mansard C,Corot C,Briguet A,Crémillieux Y,Canet-Soulas E

    更新日期:2007-12-01 00:00:00

  • Characterization and correction of center-frequency effects in X-nuclear eddy current compensations on a clinical MR system.

    abstract:PURPOSE:The aim of the study was to investigate whether incorrectly compensated eddy currents are the source of persistent X-nuclear spectroscopy and imaging artifacts, as well as methods to correct this. METHODS:Pulse-acquire spectra were collected for 1 H and X-nuclei (23 Na or 31 P) using the minimum TR permitted o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28607

    authors: McLean MA,Hinks RS,Kaggie JD,Woitek R,Riemer F,Graves MJ,McIntyre DJO,Gallagher FA,Schulte RF

    更新日期:2020-12-04 00:00:00

  • Quantitative magnetization transfer imaging in human brain at 3 T via selective inversion recovery.

    abstract::Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons-including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools k(mf) . This study describes the first implementation of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22928

    authors: Dortch RD,Li K,Gochberg DF,Welch EB,Dula AN,Tamhane AA,Gore JC,Smith SA

    更新日期:2011-11-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

    abstract::Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varyin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20928

    authors: Kim DH,Spielman DM

    更新日期:2006-07-01 00:00:00

  • Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

    abstract::A new parallel imaging technique was implemented which can result in reduced image acquisition times in MRI. MR data is acquired in parallel using an array of receiver coils and then reconstructed simultaneously with multiple processors. The method requires the initial estimation of the 2D sensitivity profile of each ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.c

    authors: Kyriakos WE,Panych LP,Kacher DF,Westin CF,Bao SM,Mulkern RV,Jolesz FA

    更新日期:2000-08-01 00:00:00

  • Characterizing the limits of MRI near metallic prostheses.

    abstract:PURPOSE:To characterize the fundamental limits of MRI near metallic implants on RF excitation, frequency encoding, and chemical shift-encoding water-fat separation. METHODS:Multicomponent three-dimensional (3D) digital models of a total hip and a total knee replacement were used to construct material-specific suscepti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25540

    authors: Smith MR,Artz NS,Wiens C,Hernando D,Reeder SB

    更新日期:2015-12-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • A hybrid method for more efficient channel-by-channel reconstruction with many channels.

    abstract::In MRI, imaging using receiving coil arrays with a large number of elements is an area of growing interest. With increasing channel numbers for parallel acquisition, longer reconstruction times have become a significant concern. Channel reduction techniques have been proposed to reduce the processing time of channel-b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23048

    authors: Huang F,Lin W,Duensing GR,Reykowski A

    更新日期:2012-03-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue.

    abstract::Chemically-fixed nervous tissues are well-suited for high-resolution, time-intensive MRI acquisitions without motion artifacts, such as those required for brain atlas projects, but the aldehyde fixatives used may significantly alter tissue MRI properties. To test this hypothesis, this study characterized the impact of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21977

    authors: Shepherd TM,Thelwall PE,Stanisz GJ,Blackband SJ

    更新日期:2009-07-01 00:00:00

  • Response of choline metabolites to docetaxel therapy is quantified in vivo by localized (31)P MRS of human breast cancer xenografts and in vitro by high-resolution (31)P NMR spectroscopy of cell extracts.

    abstract::Choline-containing compounds (CCCs) are elevated in breast cancer, and detected in vivo by the (1)H MRS total choline (tCho) resonance (3.25 ppm) and the (31)P MRS phosphomonoester (PME) resonance (3.8 ppm). Both the tCho and PME resonances decrease early after initiation of successful therapy. The single major compon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21333

    authors: Morse DL,Raghunand N,Sadarangani P,Murthi S,Job C,Day S,Howison C,Gillies RJ

    更新日期:2007-08-01 00:00:00

  • Efficient visualization of vascular territories in the human brain by cycled arterial spin labeling MRI.

    abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20998

    authors: Günther M

    更新日期:2006-09-01 00:00:00

  • Chemically induced analgesic nephropathy in the rat monitored by proton-electron double-resonance imaging (PEDRI).

    abstract::Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl carboxylic acid (PCA) through normal and injured kidneys in the living rat. Kidney damage was induced by treatment with 2-bromoethylamine (BEA), which provides a well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400214

    authors: Seimenis I,Foster MA,Lurie DJ,Hutchison JM,Whiting PH,Payne S

    更新日期:1998-08-01 00:00:00

  • Interleaved variable density sampling with a constrained parallel imaging reconstruction for dynamic contrast-enhanced MR angiography.

    abstract::For MR applications such as contrast-enhanced MR angiography, it is desirable to achieve simultaneously high spatial and temporal resolution. The current clinical standard uses view-sharing methods combined with parallel imaging; however, this approach still provides limited spatial and temporal resolution. To improve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22814

    authors: Wang K,Busse RF,Holmes JH,Beatty PJ,Brittain JH,Francois CJ,Reeder SB,Du J,Korosec FR

    更新日期:2011-08-01 00:00:00

  • The development of a pH-sensitive contrast agent for NMR 1H imaging.

    abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050313

    authors: Helpern JA,Curtis JC,Hearshen D,Smith MB,Welch KM

    更新日期:1987-09-01 00:00:00

  • High-resolution 1H NMR spectroscopy in the diagnosis of breast cancer.

    abstract::Surgical specimens from 22 patients with infiltrating ductal carcinoma of the breast were analyzed by high-resolution 1H NMR spectroscopy at 80 and 300 MHz. Results were compared with those obtained from 9 benign (proliferative dysplasia without atypia) breast samples. NMR spectra at 80 MHz showed well-resolved water ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080407

    authors: Bradamante S,Barchiesi E,Pilotti S,Borasi G

    更新日期:1988-12-01 00:00:00

  • Feasibility of multiple-mouse dynamic contrast-enhanced MRI.

    abstract::Dynamic contrast-enhanced (DCE-) MRI is often used to evaluate the response to experimental antiangiogenic therapies in small animal models of cancer. Unfortunately, DCE-MRI studies often require a substantial investment of both time and money to achieve the desired level of statistical significance. Multiple-mouse MR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21348

    authors: Ramirez MS,Ragan DK,Kundra V,Bankson JA

    更新日期:2007-09-01 00:00:00

  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

    abstract:PURPOSE:A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements. THEORY AND METHODS:An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28068

    authors: Cao Z,Yan X,Gore JC,Grissom WA

    更新日期:2020-06-01 00:00:00

  • T2 accuracy on a whole-body imager.

    abstract::MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380512

    authors: Foltz WD,Stainsby JA,Wright GA

    更新日期:1997-11-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Diffusion-weighted NMR spectroscopy allows probing of 13C labeling of glutamate inside distinct metabolic compartments in the brain.

    abstract::In the present work, diffusion-weighted (DW)-NMR spectroscopy of glutamate was performed during a (13)C-labeled glucose infusion in monkey brain (six experiments). It is shown that glutamate (13)C labeling occurs significantly faster at higher diffusion weightings-slightly for glutamate in position C4, and more marked...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21661

    authors: Valette J,Chaumeil M,Guillermier M,Bloch G,Hantraye P,Lebon V

    更新日期:2008-08-01 00:00:00

  • DeepCEST: 9.4 T Chemical exchange saturation transfer MRI contrast predicted from 3 T data - a proof of concept study.

    abstract:PURPOSE:To determine the feasibility of employing the prior knowledge of well-separated chemical exchange saturation transfer (CEST) signals in the 9.4 T Z-spectrum to separate overlapping CEST signals acquired at 3 T, using a deep learning approach trained with 3 T and 9.4 T CEST spectral data from brains of the same ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27690

    authors: Zaiss M,Deshmane A,Schuppert M,Herz K,Glang F,Ehses P,Lindig T,Bender B,Ernemann U,Scheffler K

    更新日期:2019-06-01 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Two-site reproducibility of cerebellar and brainstem neurochemical profiles with short-echo, single-voxel MRS at 3T.

    abstract:PURPOSE:To determine whether neurochemical concentrations obtained at two MRI sites using clinical 3T scanners can be pooled when a highly optimized, nonvendor short-echo, single-voxel proton MRS pulse sequence is used in conjunction with identical calibration and quantification procedures. METHODS:A modified semi-LAS...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25295

    authors: Deelchand DK,Adanyeguh IM,Emir UE,Nguyen TM,Valabregue R,Henry PG,Mochel F,Öz G

    更新日期:2015-05-01 00:00:00

  • Single-scan MRI with exceptional resilience to field heterogeneities.

    abstract:PURPOSE:Single-scan two-dimensional MRI has been generally constrained to acquisitions in high quality magnets. This study introduces a methodology, cross-term spatiotemporal encoding (xSPEN), that delivers such images under much poorer external field conditions. METHODS:xSPEN departs from conventional k-space scannin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26145

    authors: Zhang Z,Seginer A,Frydman L

    更新日期:2017-02-01 00:00:00

  • Strain-dependent T1 relaxation profiles in articular cartilage by MRI at microscopic resolutions.

    abstract::To investigate the dependency of T(1) relaxation on mechanical strain in articular cartilage, quantitative magnetic resonance T(1) imaging experiments were carried out on cartilage before/after the tissue was immersed in gadolinium contrast agent and when the tissue was being compressed (up to ∼ 48% strains). The spat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22933

    authors: Xia Y,Wang N,Lee J,Badar F

    更新日期:2011-06-01 00:00:00

  • Whole-heart chemical shift encoded water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS:We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24982

    authors: Taviani V,Hernando D,Francois CJ,Shimakawa A,Vigen KK,Nagle SK,Schiebler ML,Grist TM,Reeder SB

    更新日期:2014-09-01 00:00:00