Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

Abstract:

:Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varying nature. In this work we describe the effects of undesirable gradient performance on SI. Measurements of the true readout trajectories were performed and the results were then used in the reconstruction process. The effects of these imperfections resulted in a spatially and spectrally varying amplitude and frequency modulation. The use of the measured trajectories in the reconstruction process yielded an up to 20% increase in signal amplitude recovery.

journal_name

Magn Reson Med

authors

Kim DH,Spielman DM

doi

10.1002/mrm.20928

subject

Has Abstract

pub_date

2006-07-01 00:00:00

pages

198-203

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

56

pub_type

杂志文章
  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • Liver stiffness assessment by tagged MRI of cardiac-induced liver motion.

    abstract::Cirrhosis is an important and growing public health problem, affecting millions of Americans and many more people internationally. A pathological hallmark of the progression to cirrhosis is the development of liver fibrosis, so that monitoring the appearance and progression of liver fibrosis can be used to guide thera...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22785

    authors: Chung S,Breton E,Mannelli L,Axel L

    更新日期:2011-04-01 00:00:00

  • Characterization and correction of center-frequency effects in X-nuclear eddy current compensations on a clinical MR system.

    abstract:PURPOSE:The aim of the study was to investigate whether incorrectly compensated eddy currents are the source of persistent X-nuclear spectroscopy and imaging artifacts, as well as methods to correct this. METHODS:Pulse-acquire spectra were collected for 1 H and X-nuclei (23 Na or 31 P) using the minimum TR permitted o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28607

    authors: McLean MA,Hinks RS,Kaggie JD,Woitek R,Riemer F,Graves MJ,McIntyre DJO,Gallagher FA,Schulte RF

    更新日期:2020-12-04 00:00:00

  • High-resolution FMRI at 1.5T using balanced SSFP.

    abstract::The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20753

    authors: Miller KL,Smith SM,Jezzard P,Pauly JM

    更新日期:2006-01-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Time-domain combination of MR spectroscopy data acquired using phased-array coils.

    abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20244

    authors: Brown MA

    更新日期:2004-11-01 00:00:00

  • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24440

    authors: Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim D

    更新日期:2013-07-01 00:00:00

  • Simultaneous QSM and metabolic imaging of the brain using SPICE.

    abstract:PURPOSE:To map brain metabolites and tissue magnetic susceptibility simultaneously using a single three-dimensional 1 H-MRSI acquisition without water suppression. METHODS:The proposed technique builds on a subspace imaging method called spectroscopic imaging by exploiting spatiospectral correlation (SPICE), which ena...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26972

    authors: Peng X,Lam F,Li Y,Clifford B,Liang ZP

    更新日期:2018-01-01 00:00:00

  • Changes in T2*-weighted images during hyperoxia differentiate tumors from normal tissue.

    abstract::Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recyc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330306

    authors: Kuperman VYu,River JN,Lewis MZ,Lubich LM,Karczmar GS

    更新日期:1995-03-01 00:00:00

  • Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

    abstract:PURPOSE:Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS:A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26197

    authors: Solomon E,Liberman G,Nissan N,Frydman L

    更新日期:2017-03-01 00:00:00

  • Effects of acute normovolemic hemodilution on T2*-weighted images of rat brain.

    abstract::Acute normovolemic hemodilution (HD) was induced in anesthetized rats to assess the effect of changes in hematocrit (Hct) on signal intensity in T2*-weighted magnetic resonance (MR) images. Other relevant physiological parameters were maintained invariant. Two degrees of HD were induced: mild (Hct reduced from 42.6+/-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400611

    authors: Lin W,Paczynski RP,Celik A,Hsu CY,Powers WJ

    更新日期:1998-12-01 00:00:00

  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • Interleaved variable density sampling with a constrained parallel imaging reconstruction for dynamic contrast-enhanced MR angiography.

    abstract::For MR applications such as contrast-enhanced MR angiography, it is desirable to achieve simultaneously high spatial and temporal resolution. The current clinical standard uses view-sharing methods combined with parallel imaging; however, this approach still provides limited spatial and temporal resolution. To improve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22814

    authors: Wang K,Busse RF,Holmes JH,Beatty PJ,Brittain JH,Francois CJ,Reeder SB,Du J,Korosec FR

    更新日期:2011-08-01 00:00:00

  • Single-shot localized echo-planar imaging (STEAM-EPI) at 4.7 tesla.

    abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140225

    authors: Turner R,von Kienlin M,Moonen CT,van Zijl PC

    更新日期:1990-05-01 00:00:00

  • Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

    abstract::A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arteria...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10733

    authors: Hernandez-Garcia L,Lee GR,Vazquez AL,Noll DC

    更新日期:2004-03-01 00:00:00

  • Quantification of regional blood volumes by rapid T1 mapping.

    abstract::A new method is presented for the quantitative determination of regional blood volumes in vivo. It is based on rapid quantitative T1 mapping by Snapshot FLASH MRI combined with the injection of an intravascular MR contrast agent. Regional blood volumes in four different tissues of the rat (skeletal muscle, heart, live...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290521

    authors: Schwarzbauer C,Syha J,Haase A

    更新日期:1993-05-01 00:00:00

  • Independent component analysis applied to diffusion tensor MRI.

    abstract::The accuracy of the outcome in a diffusion tensor imaging (DTI) experiment depends on the acquisition scheme as well as the postprocessing methods used. In the present study, the DTI results acquired after applying different combinations of diffusion-weighted (DW) gradient orientations were initially compared. Then, s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10046

    authors: Arfanakis K,Cordes D,Haughton VM,Carew JD,Meyerand ME

    更新日期:2002-02-01 00:00:00

  • Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

    abstract::The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20541

    authors: Meara SJ,Barker GJ

    更新日期:2005-07-01 00:00:00

  • Regional comparison of tumor vascularity and permeability parameters measured by albumin-Gd-DTPA and Gd-DTPA.

    abstract::Sequential albumin-Gd-DTPA and Gd-DTPA dynamic enhancement studies were performed in an animal tumor model for the comparison of regional vascularity and permeability parameters measured by these two different sizes of contrast agents. The early albumin-Gd-DTPA enhancement arises from the vascular compartment, and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340318

    authors: Su MY,Najafi AA,Nalcioglu O

    更新日期:1995-09-01 00:00:00

  • In vivo 3.0-tesla magnetic resonance T1rho and T2 relaxation mapping in subjects with intervertebral disc degeneration and clinical symptoms.

    abstract::The purpose of this study is (1) to determine the correlation between T(1rho) and T(2) and degenerative grade in intervertebral discs using in vivo 3.0-T MRI, and (2) to determine the association between T(1rho) and T(2) and clinical findings as quantified by the SF-36 Questionnaire and Oswestry Disability Index. Sixt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22362

    authors: Blumenkrantz G,Zuo J,Li X,Kornak J,Link TM,Majumdar S

    更新日期:2010-05-01 00:00:00

  • Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

    abstract::Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5-mm midventricular axial slice was sampled using a modified Look-Locker technique with 1.5 mm in-plane resolution, and 32 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21122

    authors: Rooney WD,Johnson G,Li X,Cohen ER,Kim SG,Ugurbil K,Springer CS Jr

    更新日期:2007-02-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times.

    abstract:PURPOSE:This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. METHODS:1 H MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28066

    authors: Dehghani M,Do KQ,Magistretti P,Xin L

    更新日期:2020-06-01 00:00:00

  • Evaluation of MRI resolution affecting trabecular bone parameters: determination of acceptable resolution.

    abstract::The objective of this study is to evaluate the effect of MR image resolution on trabecular bone parameters and to determine the acceptable resolution that can be accurately analyzed to assess structural parameters. Ten distal femoral condyle specimens of 1 × 1 × 1 cm(3) were scanned with a 4.7-T Bruker BioSpec MRI sca...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22984

    authors: Kim N,Lee JG,Song Y,Kim HJ,S Yeom J,Cho G

    更新日期:2012-01-01 00:00:00

  • Lung imaging under free-breathing conditions.

    abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21846

    authors: Oechsner M,Pracht ED,Staeb D,Arnold JF,Köstler H,Hahn D,Beer M,Jakob PM

    更新日期:2009-03-01 00:00:00

  • Transrectal probe for 1H MRI and 31P MR spectroscopy of the prostate gland.

    abstract::A transrectal probe for 1H imaging and 31P MR spectroscopy of the prostate gland is described. The probe is covered with plastic and consists of an insectional portion containing an rf coil and a handle containing a tuning and matching circuit. Using this transrectal probe, 1H MR images and the first 31P MR spectra of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910110209

    authors: Narayan P,Vigneron DB,Jajodia P,Anderson CM,Hedgcock MW,Tanagho EA,James TL

    更新日期:1989-08-01 00:00:00

  • Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

    abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20714

    authors: Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

    更新日期:2005-12-01 00:00:00

  • Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

    abstract::The integrated T(1)-T(2) characteristics of rat brain and trigeminal nerve water were studied in vivo using a rapid method for acquiring a series of images that depend on T(1) and T(2) relaxation times. Gray matter regions showed only one signal component in both the T(1) and T(2) domains. Trigeminal nerve, however, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10060

    authors: Does MD,Gore JC

    更新日期:2002-02-01 00:00:00

  • Performance evaluation of whole-body NMR scanner antenna systems.

    abstract::Whole-body NMR imaging antennas (probes) are strongly affected by the inevitable magnetic and controllable dielectric losses. Using a convenient parallelepiped model, the magnetic losses are evaluated. By introducing the "ideal power gain," the best possible antenna performance is delimited as a function of the freque...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020403

    authors: Sergiadis G

    更新日期:1985-08-01 00:00:00

  • Imaging articular cartilage under compression--cartilage elastography.

    abstract::We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20439

    authors: Hardy PA,Ridler AC,Chiarot CB,Plewes DB,Henkelman RM

    更新日期:2005-05-01 00:00:00