Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

Abstract:

:The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were carried out 1-30 days after implantation with or without control of core body temperature. The pO(2) values in the tissue became stable 2 weeks after implantation of LiPc crystals. The pO(2) level was found to be higher in the femoral muscle than in the mammary tissue. However, the pO(2) values showed a strong dependence on the core body temperature of the mice. The pO(2) values were responsive to carbogen (95% O(2), 5% CO(2)) breathing even 44-58 days after the implantation of LiPc. The LiPc linewidth was also sensitive to changes in the blood supply even 60 days after implantation of the crystals. This study further validates the use of LiPc crystals and EPR oximetry for long-term non-invasive assessment of pO(2) levels in tissues, underscores the importance of maintaining normal body core temperature during the measurements, and demonstrates that mammary tissue functions at a lower pO(2) level than muscle in female C3H mice.

journal_name

Magn Reson Med

authors

Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

doi

10.1002/mrm.20714

subject

Has Abstract

pub_date

2005-12-01 00:00:00

pages

1530-5

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

54

pub_type

杂志文章
  • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession.

    abstract::Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20159

    authors: Deoni SC,Ward HA,Peters TM,Rutt BK

    更新日期:2004-08-01 00:00:00

  • Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

    abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21194

    authors: Devasahayam N,Subramanian S,Murugesan R,Hyodo F,Matsumoto K,Mitchell JB,Krishna MC

    更新日期:2007-04-01 00:00:00

  • Inversion recovery radial MRI with interleaved projection sets.

    abstract::The radial trajectory has found applications in cardiac imaging because of its resilience to undersampling and motion artifacts. Recent work has shown that interleaved and weighted radial imaging can produce images with multiple contrasts from a single data set. This feature was investigated for inversion recovery ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20865

    authors: Peters DC,Botnar RM,Kissinger KV,Yeon SB,Appelbaum EA,Manning WJ

    更新日期:2006-05-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • Multi-gradient echo with susceptibility inhomogeneity compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3.0 T.

    abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370304

    authors: Yang QX,Dardzinski BJ,Li S,Eslinger PJ,Smith MB

    更新日期:1997-03-01 00:00:00

  • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24440

    authors: Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim D

    更新日期:2013-07-01 00:00:00

  • ΔR2 (*) gadolinium-diethylenetriaminepentacetic acid relaxivity in venous blood.

    abstract::The accuracy of perfusion measurements using dynamic, susceptibility-weighted, contrast-enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both bloo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24331

    authors: Patil V,Johnson G

    更新日期:2013-04-01 00:00:00

  • Free breathing lung T1 mapping using image registration in patients with idiopathic pulmonary fibrosis.

    abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28342

    authors: Saunders LC,Eaden JA,Bianchi SM,Swift AJ,Wild JM

    更新日期:2020-12-01 00:00:00

  • Imaging articular cartilage under compression--cartilage elastography.

    abstract::We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20439

    authors: Hardy PA,Ridler AC,Chiarot CB,Plewes DB,Henkelman RM

    更新日期:2005-05-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises.

    abstract:PURPOSE:To develop and test real-time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. METHODS:In 15 healthy participants, 6 groups of lower-leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28095

    authors: Schrank F,Warmuth C,Görner S,Meyer T,Tzschätzsch H,Guo J,Uca YO,Elgeti T,Braun J,Sack I

    更新日期:2020-07-01 00:00:00

  • Evidence for a contribution of paramagnetic ions to water proton spin-lattice relaxation in normal and malignant mouse tissues.

    abstract::Paramagnetic ions complexed to proteins may lose, retain, or enhance solvent paramagnetic relaxation (SPR) relative to free solution. We measured T1 and T2 of three mouse cancers, their normal counterparts, and six additional tissues. Long T1 of cancers was not caused by necrosis or by different contents of water, fat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180204

    authors: Negendank W,Corbett T,Crowley M,Kellogg C

    更新日期:1991-04-01 00:00:00

  • Quantification of regional blood volumes by rapid T1 mapping.

    abstract::A new method is presented for the quantitative determination of regional blood volumes in vivo. It is based on rapid quantitative T1 mapping by Snapshot FLASH MRI combined with the injection of an intravascular MR contrast agent. Regional blood volumes in four different tissues of the rat (skeletal muscle, heart, live...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290521

    authors: Schwarzbauer C,Syha J,Haase A

    更新日期:1993-05-01 00:00:00

  • Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

    abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25785

    authors: Xie Y,Yang Q,Xie G,Pang J,Fan Z,Li D

    更新日期:2016-06-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • Comparison between 8- and 32-channel phased-array receive coils for in vivo hyperpolarized 13 C imaging of the human brain.

    abstract:PURPOSE:To compare the performance of an 8-channel surface coil/clamshell transmitter and 32-channel head array coil/birdcage transmitter for hyperpolarized 13 C brain metabolic imaging. METHODS:To determine the field homogeneity of the radiofrequency transmitters, B1 + mapping was performed on an ethylene glycol head...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27743

    authors: Autry AW,Gordon JW,Carvajal L,Mareyam A,Chen HY,Park I,Mammoli D,Vareth M,Chang SM,Wald LL,Xu D,Vigneron DB,Nelson SJ,Li Y

    更新日期:2019-08-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • Comparison of measuring energy metabolism by different (31) P-magnetic resonance spectroscopy techniques in resting, ischemic, and exercising muscle.

    abstract::Alternate methods to quantify mitochondrial activity or function have been extensively used for studying insulin resistance and type 2 diabetes mellitus, namely saturation transfer and phosphocreatine (PCr) recovery. As these methods are in fact determining different parameters, this study aimed to compare saturation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23095

    authors: Schmid AI,Schrauwen-Hinderling VB,Andreas M,Wolzt M,Moser E,Roden M

    更新日期:2012-04-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Four-dimensional flow MRI using spiral acquisition.

    abstract::Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23297

    authors: Sigfridsson A,Petersson S,Carlhäll CJ,Ebbers T

    更新日期:2012-10-01 00:00:00

  • Simplified synthesis and relaxometry of magnetoferritin for magnetic resonance imaging.

    abstract::Magnetoferritin nanoparticles have been developed as high-relaxivity, functional contrast agents for MRI. Several previous techniques have relied on unloading native ferritin and re-incorporation of iron into the core, often resulting in a polydisperse sample. Here, a simplified technique is developed using commercial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22526

    authors: Jordan VC,Caplan MR,Bennett KM

    更新日期:2010-11-01 00:00:00

  • Editing through multiple bonds: threonine detection.

    abstract::In in vivo (1)H spectroscopy, the signal at 1.32 ppm is usually assigned to lactate. This resonance position is shared with threonine at physiological pH. The similarity of spectral patterns of lactate and threonine renders the separate measurement of either threonine or lactate without and even with editing technical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21492

    authors: Marjanska M,Henry PG,Uğurbil K,Gruetter R

    更新日期:2008-02-01 00:00:00

  • Assessment of quantitative artificial neural network analysis in a metabolically dynamic ex vivo 31P NMR pig liver study.

    abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380522

    authors: Ala-Korpela M,Changani KK,Hiltunen Y,Bell JD,Fuller BJ,Bryant DJ,Taylor-Robinson SD,Davidson BR

    更新日期:1997-11-01 00:00:00

  • DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

    abstract::A novel multislice B₁-mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acqu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24158

    authors: Nehrke K,Börnert P

    更新日期:2012-11-01 00:00:00

  • Training a neural network for Gibbs and noise removal in diffusion MRI.

    abstract:PURPOSE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28395

    authors: Muckley MJ,Ades-Aron B,Papaioannou A,Lemberskiy G,Solomon E,Lui YW,Sodickson DK,Fieremans E,Novikov DS,Knoll F

    更新日期:2021-01-01 00:00:00

  • Automatic in-line quantitative myocardial perfusion mapping: Processing algorithm and implementation.

    abstract:PURPOSE:Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27954

    authors: Xue H,Brown LAE,Nielles-Vallespin S,Plein S,Kellman P

    更新日期:2020-02-01 00:00:00

  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • On consideration of radiated power in RF field simulations for MRI.

    abstract::In numerical analyses of radiofrequency (RF) fields for MRI, RF power is often permitted to radiate out of the problem region. In reality, RF power will be confined by the magnet bore and RF screen enclosing the magnet room. We present numerical calculations at different frequencies for various surface and volume coil...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24244

    authors: Liu W,Kao CP,Collins CM,Smith MB,Yang QX

    更新日期:2013-01-01 00:00:00