Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

Abstract:

PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in which image reconstruction relies on quantification of data correlation. The presented work integrates correlation imaging with a wavelet transform technique developed originally in the field of signal and image processing. This provides a new high-speed MRI approach to motion-free data collection without motion monitoring or data segmentation. The new approach, called "wavelet-space correlation imaging", is investigated in brain imaging with involuntary motion and chest imaging with free-breathing. RESULTS:Wavelet-space correlation imaging can exceed the speed limit of conventional parallel imaging methods. Using this approach with high acceleration factors (6 for brain MRI, 16 for cardiac MRI, and 8 for lung MRI), motion-free images can be generated in static brain MRI with involuntary motion and nonsegmented dynamic cardiac/lung MRI with free-breathing. CONCLUSION:Wavelet-space correlation imaging enables high-speed MRI in the presence of involuntary motion or physiological dynamics without motion monitoring or data segmentation.

journal_name

Magn Reson Med

authors

Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

doi

10.1002/mrm.25546

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

1574-86

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

74

pub_type

杂志文章
  • Regional and temporal variations in tissue sodium concentration during the acute stroke phase.

    abstract::A technique for noninvasively quantifying the concentration of sodium ((23) Na) ions was applied to the study of ischemic stroke. (23) Na-magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23031

    authors: Wetterling F,Gallagher L,Macrae IM,Junge S,Fagan AJ

    更新日期:2012-03-01 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • Multi-turn transmit coil to increase b1 efficiency in current source amplification.

    abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24612

    authors: Gudino N,Griswold MA

    更新日期:2013-04-01 00:00:00

  • Indirect 17(O)-magnetic resonance imaging of cerebral blood flow in the rat.

    abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10403

    authors: Tailor DR,Roy A,Regatte RR,Charagundla SR,McLaughlin AC,Leigh JS,Reddy R

    更新日期:2003-03-01 00:00:00

  • Quantitative and qualitative fat analysis in human leg muscle of neuromuscular diseases by 1H MR spectroscopy in vivo.

    abstract::1H MR spectra were recorded from human gastrocnemius muscle at 63.86 MHz using the body coil of the Signa scanner as transmitter and a 3-in. surface coil as receiver. The fat content of the muscle was quantified relative to that of water in a selected volume or slice. The fat/water ratio was 0.05-0.07 for normal muscl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910100206

    authors: Bárány M,Venkatasubramanian PN,Mok E,Siegel IM,Abraham E,Wycliffe ND,Mafee MF

    更新日期:1989-05-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Reconstruction by calibration over tensors for multi-coil multi-acquisition balanced SSFP imaging.

    abstract:PURPOSE:To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. METHODS:...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26902

    authors: Biyik E,Ilicak E,Çukur T

    更新日期:2018-05-01 00:00:00

  • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

    abstract::Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400517

    authors: Jesmanowicz A,Bandettini PA,Hyde JS

    更新日期:1998-11-01 00:00:00

  • Dysprosium-bearing red cells as potential transverse relaxation agents for MRI.

    abstract::The cytosol of intact human red blood cells was loaded with 28.1 +/- 3.4 mM of dysprosium DTPA-BMA using a hypoosmotic technique. When loaded cells were diluted with saline and control cells to give an average dysprosium concentration of 3.3 +/- 0.5 mM, the transverse relaxation rate constants R(*)(2) and R(2) increas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1122

    authors: Johnson KM,Tao JZ,Kennan RP,Gore JC

    更新日期:2001-05-01 00:00:00

  • Parallel reconstruction using null operations.

    abstract::A novel iterative k-space data-driven technique, namely parallel reconstruction using null operations (PRUNO), is presented for parallel imaging reconstruction. In PRUNO, both data calibration and image reconstruction are formulated into linear algebra problems based on a generalized system model. An optimal data cali...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22899

    authors: Zhang J,Liu C,Moseley ME

    更新日期:2011-11-01 00:00:00

  • Algorithms for extracting motion information from navigator echoes.

    abstract::Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360120

    authors: Wang Y,Grimm RC,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1996-07-01 00:00:00

  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Fast acquisition-weighted three-dimensional proton MR spectroscopic imaging of the human prostate.

    abstract::The clinical application of 3D proton spectroscopic imaging (3D SI) of the human prostate requires a robust suppression of periprostatic lipid signal contamination, minimal intervoxel signal contamination, and the shortest possible measurement time. In this work, a weighted elliptical sampling of k-space, combined wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20103

    authors: Scheenen TW,Klomp DW,Röll SA,Fütterer JJ,Barentsz JO,Heerschap A

    更新日期:2004-07-01 00:00:00

  • Analytical solution and verification of diffusion effect in SSFP.

    abstract::Assuming that the SSFP magnetization response maintains a steady state which is periodic in the presence of diffusion, we can solve for the diffusion effect in such sequences. Formulating a Fourier series decomposition solution to the Bloch-Torrey equation and imposing the steady-state condition, analytical expression...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190209

    authors: Carney CE,Wong ST,Patz S

    更新日期:1991-06-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

    abstract::Chemical exchange saturation transfer (CEST), arterial spin labeling (ASL), and magnetization transfer contrast (MTC) methods generate different contrasts for MRI. However, they share many similarities in terms of pulse sequences and mechanistic principles. They all use RF pulse preparation schemes to label the longit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27341

    authors: Knutsson L,Xu J,Ahlgren A,van Zijl PCM

    更新日期:2018-10-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • MRI of [2-13 C]Lactate without J-coupling artifacts.

    abstract:PURPOSE:Imaging of [2-13 C]lactate, a metabolic product of [2-13 C]pyruvate, is over considerable interest in hyperpolarized 13 C studies. However, artifact-free imaging of a J-coupled nuclear spin species can be challenging due to the peak-splitting induced by the spin-spin interactions. In this work, two new techniqu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28532

    authors: Datta K,Spielman D

    更新日期:2021-03-01 00:00:00

  • Gradient field switching as a source for artifacts in MR imaging of metallic stents.

    abstract::Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequency- (RF) and susceptibility-induced artifacts have been thoroughly investigated. However, gradient-switching-in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20294

    authors: Shenhav A,Azhari H

    更新日期:2004-12-01 00:00:00

  • Magnesium and pH imaging of the human brain at 3.0 Tesla.

    abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26

    authors: Barker PB,Butterworth EJ,Boska MD,Nelson J,Welch KM

    更新日期:1999-02-01 00:00:00

  • Optimized 3D ultrashort echo time pulmonary MRI.

    abstract:PURPOSE:To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS:3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise pe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24570

    authors: Johnson KM,Fain SB,Schiebler ML,Nagle S

    更新日期:2013-11-01 00:00:00

  • A magnetic shield for large-bore, high field magnets.

    abstract::An effective shield for the dc fringing fields produced by a large-bore, high field magnet intended for imaging and in vivo spectroscopy is presented. While limiting the extent of fringe fields, the shield has little effect on the homogeneity of the central field of the magnet. The effect of institutional safety polic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020506

    authors: Ewing JR,Timms W,Williams JE,Welch KM

    更新日期:1985-10-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00

  • SAR comparison between CASL and pCASL at high magnetic field and evaluation of the benefit of a dedicated labeling coil.

    abstract:PURPOSE:To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS:Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27931

    authors: Hirschler L,Collomb N,Voiron J,Köhler S,Barbier EL,Warnking JM

    更新日期:2020-01-01 00:00:00

  • Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24114

    authors: Tam LK,Stockmann JP,Galiana G,Constable RT

    更新日期:2012-10-01 00:00:00

  • Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.

    abstract:PURPOSE:Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS:A truly hybrid US...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26897

    authors: Celicanin Z,Manasseh G,Petrusca L,Scheffler K,Auboiroux V,Crowe LA,Hyacinthe JN,Natsuaki Y,Santini F,Becker CD,Terraz S,Bieri O,Salomir R

    更新日期:2018-05-01 00:00:00

  • Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction.

    abstract:PURPOSE:To explore the effects of high permittivity dielectric pads on the transmit and receive characteristics of a 3 Tesla body coil centered at the thighs, and their implications on image uniformity in receive array applications. THEORY AND METHODS:Transmit and receive profiles of the body coil with and without die...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26070

    authors: Brink WM,Versluis MJ,Peeters JM,Börnert P,Webb AG

    更新日期:2016-12-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00