Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

Abstract:

:Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for high-resolution full k-space acquisition gives rise to severe susceptibility effects. These problems are substantially reduced by acquiring only half of k-space and filling the empty side by Hermitian conjugate formation. Details of the pulse sequence and image reconstruction are presented. The point-spread function is 3(1/2) times narrower for half than full k-space acquisition. Experiments as well as theoretical considerations were carried out in a context of fMRI using a whole-brain local gradient and an RF coil at 3 Tesla. Using a bandwidth of +/-83 kHz, well-resolved single-shot images of the human brain, as well as good quality fMRI data sets were obtained with a matrix of 192 x 192 over 16 x 16 cm2 FOV using half k-space techniques. The combination of high spatial resolution using the methods presented in this article and the high temporal resolution of EPI opens opportunities for research into fMRI contrast mechanisms. Increase of percent signal change as the resolution increases is attributed to reduction of partial volume effects of activated voxels. Histograms of fMRI pixel responses are progressively weighted to higher percent signal changes as the resolution increases. The conclusion has been reached that half k-space GR-EPI is generally superior to full k-space GR-EPI and should be used even for low-resolution (64 x 64) EPI.

journal_name

Magn Reson Med

authors

Jesmanowicz A,Bandettini PA,Hyde JS

doi

10.1002/mrm.1910400517

subject

Has Abstract

pub_date

1998-11-01 00:00:00

pages

754-62

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

40

pub_type

杂志文章
  • A molecular MRI probe to detect treatment of cardiac apoptosis in vivo.

    abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22876

    authors: Dash R,Chung J,Chan T,Yamada M,Barral J,Nishimura D,Yang PC,Simpson PC

    更新日期:2011-10-01 00:00:00

  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations.

    abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26333

    authors: McGrath DM,Ravikumar N,Beltrachini L,Wilkinson ID,Frangi AF,Taylor ZA

    更新日期:2017-07-01 00:00:00

  • Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF.

    abstract:PURPOSE:The purpose of this study is to increase the robustness of MR fingerprinting (MRF) toward subject motion. METHODS:A novel reconstruction algorithm, MOtion insensitive MRF (MORF), was developed, which uses an iterative reconstruction based retrospective motion correction approach. Each iteration loops through t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27227

    authors: Mehta BB,Ma D,Pierre EY,Jiang Y,Coppo S,Griswold MA

    更新日期:2018-12-01 00:00:00

  • Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

    abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27439

    authors: Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

    更新日期:2019-01-01 00:00:00

  • Editing through multiple bonds: threonine detection.

    abstract::In in vivo (1)H spectroscopy, the signal at 1.32 ppm is usually assigned to lactate. This resonance position is shared with threonine at physiological pH. The similarity of spectral patterns of lactate and threonine renders the separate measurement of either threonine or lactate without and even with editing technical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21492

    authors: Marjanska M,Henry PG,Uğurbil K,Gruetter R

    更新日期:2008-02-01 00:00:00

  • Measurements of human cerebral GABA at 4.1 T using numerically optimized editing pulses.

    abstract::The goal of this work was to develop and evaluate a numerically optimized inversion pulse to be used with a homonuclear editing sequence to measure human cerebral GABA in vivo at 4.1 T in the occipital lobe. The optimized pulse was constructed using pallindromic symmetry with 30 pulses and 29 delays. The optimized pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390103

    authors: Hetherington HP,Newcomer BR,Pan JW

    更新日期:1998-01-01 00:00:00

  • Per-subject characterization of bolus width in pulsed arterial spin labeling using bolus turbo sampling.

    abstract::Quantification of cerebral blood flow using QUIPSSII pulsed arterial spin labeling requires that the QUIPSS saturation delay TI1 is shorter than the natural temporal bolus width. Yet the duration of the bolus of tagged spins entering the region of interest varies during vasoactive stimuli such as gaseous challenges or...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24412

    authors: Villien M,Chipon E,Troprès I,Bouvier J,Cantin S,Chechin D,Le Bas JF,Krainik A,Warnking JM

    更新日期:2013-06-01 00:00:00

  • In vitro study to simulate the intracardiac magnetohydrodynamic effect.

    abstract:PURPOSE:Blood flow causes induced voltages via the magnetohydrodynamic (MHD) effect distorting electrograms (EGMs) made during magnetic resonance imaging. To investigate the MHD effect in this context MHD voltages occurring inside the human heart were simulated in an in vitro model system inside a 1.5 T MR system. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25456

    authors: Buchenberg WB,Mader W,Hoppe G,Lorenz R,Menza M,Büchert M,Timmer J,Jung B

    更新日期:2015-09-01 00:00:00

  • Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

    abstract::Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22725

    authors: Yang C,Deng W,Stenger VA

    更新日期:2011-02-01 00:00:00

  • Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

    abstract::Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27742

    authors: Wilson M,Andronesi O,Barker PB,Bartha R,Bizzi A,Bolan PJ,Brindle KM,Choi IY,Cudalbu C,Dydak U,Emir UE,Gonzalez RG,Gruber S,Gruetter R,Gupta RK,Heerschap A,Henning A,Hetherington HP,Huppi PS,Hurd RE,Kantarci K,Ka

    更新日期:2019-08-01 00:00:00

  • Investigation of the early response to rat forepaw stimulation.

    abstract::The role of relative cerebral blood volume (rCBV) in the early response of blood oxygenation level-dependent (BOLD) signal following sensory stimulation was assessed. Magnetic resonance imaging (MRI) measurements of rCBV and BOLD signal as a function of time (t) were compared with relative cerebral blood flow (rCBF) o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<247::aid-mrm6>

    authors: Marota JJ,Ayata C,Moskowitz MA,Weisskoff RM,Rosen BR,Mandeville JB

    更新日期:1999-02-01 00:00:00

  • Estimating T1 from multichannel variable flip angle SPGR sequences.

    abstract::Quantitative estimation of T1 is a challenging but important task inherent to many clinical applications. The most commonly used paradigm for estimating T1 in vivo involves performing a sequence of spoiled gradient-recalled echo acquisitions at different flip angles, followed by fitting of an exponential model to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24401

    authors: Trzasko JD,Mostardi PM,Riederer SJ,Manduca A

    更新日期:2013-06-01 00:00:00

  • 31P RINEPT MRSI and VBM reveal alterations in brain aging associated with major depression.

    abstract:PURPOSE:Phosphomono- and diesters, the major components of the choline peak in (1) H magnetic resonance spectroscopy, are associated with membrane anabolic and catabolic mechanisms. With the refocused insensitive nuclei-enhanced polarization transfer technique, these phospholipids are edited and enhanced in the (31) P ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25278

    authors: Biedermann SV,Weber-Fahr W,Demirakca T,Tunc-Skarka N,Hoerst M,Henn F,Sartorius A,Ende G

    更新日期:2015-04-01 00:00:00

  • On the use of double-quantum coherence from an AX3 system (protons in lactate) for spectral editing.

    abstract::The suppression of water signals in in vivo proton spectra by means of multiple-quantum filtering can be brought about in several ways. This communication exposes the shortcomings of using purely subtractive filtering techniques to observe signals from metabolites that contain proton couplings of the form AX3. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110314

    authors: Nosel W,Trimble LA,Shen JF,Allen PS

    更新日期:1989-09-01 00:00:00

  • Dynamic per slice shimming for simultaneous brain and spinal cord fMRI.

    abstract:PURPOSE:Simultaneous brain and spinal cord functional MRI is emerging as a new tool to study the central nervous system but is challenging. Poor B0 homogeneity and small size of the spinal cord are principal obstacles to this nascent technology. Here we extend a dynamic shimming approach, first posed by Finsterbusch, b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27388

    authors: Islam H,Law CSW,Weber KA,Mackey SC,Glover GH

    更新日期:2019-02-01 00:00:00

  • Regional and temporal variations in tissue sodium concentration during the acute stroke phase.

    abstract::A technique for noninvasively quantifying the concentration of sodium ((23) Na) ions was applied to the study of ischemic stroke. (23) Na-magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23031

    authors: Wetterling F,Gallagher L,Macrae IM,Junge S,Fagan AJ

    更新日期:2012-03-01 00:00:00

  • Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

    abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20848

    authors: Sabati M,Lauzon ML,Mahallati H,Frayne R

    更新日期:2006-05-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • Quantitative MRI of Gd-DTPA uptake in tumors: response to photodynamic therapy.

    abstract::A partial saturation method is described for obtaining rapid images of tissue 1H spin-lattice relaxation rates following administration of the paramagnetic contrast agent gadolinium-diethylenetriaminepentaacetate. The paramagnetic contribution to the relaxation rates is proportional to the concentration of contrast ag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310308

    authors: Kennedy SD,Szczepaniak LS,Gibson SL,Hilf R,Foster TH,Bryant RG

    更新日期:1994-03-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • GlucoCEST imaging with on-resonance variable delay multiple pulse (onVDMP) MRI.

    abstract:PURPOSE:To examine the detection sensitivity for the rapidly exchanging hydroxyl protons of D-glucose using the recently developed on-resonance variable delay multi-pulse (onVDMP) chemical exchange saturation transfer (CEST) technique. METHODS:The onVDMP method was applied for the detection of water signal changes upo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27364

    authors: Xu X,Xu J,Chan KWY,Liu J,Liu H,Li Y,Chen L,Liu G,van Zijl PCM

    更新日期:2019-01-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    abstract::The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22189

    authors: Tieng QM,Vegh V,Brereton IM

    更新日期:2010-01-01 00:00:00

  • Echo-planar imaging of the human fetus in utero.

    abstract::We have demonstrated that echo-planar imaging can be used to produce high-quality snapshot images of the human fetus in utero in a fraction of a second. These images are free of motional artifact or blurring and allow detailed depiction of fetal structures in normal and pathological pregnancies. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130214

    authors: Stehling MK,Mansfield P,Ordidge RJ,Coxon R,Chapman B,Blamire A,Gibbs P,Johnson IR,Symonds EM,Worthington BS

    更新日期:1990-02-01 00:00:00

  • Application of DENSE-MR-elastography to the human heart.

    abstract::Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibrat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22124

    authors: Robert B,Sinkus R,Gennisson JL,Fink M

    更新日期:2009-11-01 00:00:00

  • Optimum flip-angles for exciting NMR with uncertain T1 values.

    abstract::T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320120

    authors: Bottomley PA,Ouwerkerk R

    更新日期:1994-07-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Optimized isotropic diffusion weighting.

    abstract::The authors introduce several sets of time-efficient gradient waveforms for applying isotropic diffusion weighting in NMR experiments. This creates signal attenuation that depends on the trace of the diffusion tensor and is therefore rotationally invariant. Numerical methods for the calculation of such gradient sets a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340202

    authors: Wong EC,Cox RW,Song AW

    更新日期:1995-08-01 00:00:00

  • Single-shot, three-dimensional "non-echo" localization method for in vivo NMR spectroscopy.

    abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co

    authors: Choi IY,Tkác I,Gruetter R

    更新日期:2000-09-01 00:00:00

  • Mapping connectomes with diffusion MRI: deterministic or probabilistic tractography?

    abstract:PURPOSE:Human connectomics necessitates high-throughput, whole-brain reconstruction of multiple white matter fiber bundles. Scaling up tractography to meet these high-throughput demands yields new fiber tracking challenges, such as minimizing spurious connections and controlling for gyral biases. The aim of this study ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27471

    authors: Sarwar T,Ramamohanarao K,Zalesky A

    更新日期:2019-02-01 00:00:00