SAR comparison between CASL and pCASL at high magnetic field and evaluation of the benefit of a dedicated labeling coil.

Abstract:

PURPOSE:To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS:Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running pCASL-EPI and CASL-EPI sequences, with labeling B1 amplitudes (B1ave ) of 3, 5, and 7 μT and using a dedicated labeling RF coil or a volume coil. From the temperature time courses, the corresponding specific absorption rate (SAR) was computed. A trade-off between SAR and labeling quality was determined based on measured inversion efficiencies. RESULTS:ASL experiments with standard parameters (B1ave = 5 µT, Tacq = 4 min, labeling with volume coil) lead to a brain temperature increase due to RF of 0.72 ± 0.46 K for pCASL and 0.25 ± 0.17 K for CASL. Using a dedicated labeling coil reduced the RF-induced SAR by a factor of 10 in the brain and a factor of 2 in the neck. Besides SAR due to RF, heat from the coil decoupling circuits produced significant temperature increases. When labeling with a dedicated coil, this mechanism was the dominant source of brain heating. At equivalent RF-SAR, CASL provided slightly superior label efficiency to pCASL and is therefore the preferred sequence when an ASL coil is available. CONCLUSION:B1ave = 4-5 µT provided a good compromise between label efficiency and SAR, both for pCASL and CASL. The sensitivity of animals to heating should be taken into account when optimizing preclinical ASL protocols and may require reducing scan duration or lowering B1ave .

journal_name

Magn Reson Med

authors

Hirschler L,Collomb N,Voiron J,Köhler S,Barbier EL,Warnking JM

doi

10.1002/mrm.27931

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

254-261

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Abnormal brain anatomical topological organization of the cognitive-emotional and the frontoparietal circuitry in major depressive disorder.

    abstract:PURPOSE:Despite the increasing understanding of major depressive disorder (MDD) using neuroimaging techniques, the topological organization of anatomical networks underlying MDD remains unclear. METHODS:The topological organization of brain anatomical networks was explored using complex network approaches. Diffusion t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25036

    authors: Qin J,Wei M,Liu H,Yan R,Luo G,Yao Z,Lu Q

    更新日期:2014-11-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla.

    abstract::MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22605

    authors: Schneider JE,Lanz T,Barnes H,Stork LA,Bohl S,Lygate CA,Ordidge RJ,Neubauer S

    更新日期:2011-01-01 00:00:00

  • Safety of gadolinium-DTPA: extended clinical experience.

    abstract::This review reports data on the general and renal tolerance of the paramagnetic contrast agent Gd-DTPA after intravenous administration. Gd-DTPA was administered usually at a dose level of 0.1-0.2 mmol/kg body wt (range: 0.005-0.25 mmol/kg body wt) in cranial, spinal and body MR indications. In phase I-IIIa studies a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910220212

    authors: Niendorf HP,Haustein J,Cornelius I,Alhassan A,Clauss W

    更新日期:1991-12-01 00:00:00

  • Whole-heart steady-state free precession coronary artery magnetic resonance angiography.

    abstract::Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10653

    authors: Weber OM,Martin AJ,Higgins CB

    更新日期:2003-12-01 00:00:00

  • Magnetic resonance imaging with T1 dispersion contrast.

    abstract::Prepolarized MRI uses pulsed magnetic fields to produce MR images by polarizing the sample at one field strength (approximately 0.5 T) before imaging at a much lower field (approximately 50 mT). Contrast reflecting the T(1) of the sample at an intermediate field strength is achieved by polarizing the sample and then a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20910

    authors: Ungersma SE,Matter NI,Hardy JW,Venook RD,Macovski A,Conolly SM,Scott GC

    更新日期:2006-06-01 00:00:00

  • 31P NMR spectroscopy of 9L cell line in culture: differential effects of high temperature on anchored cells and spheroids.

    abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190233

    authors: Suzuki N,Kwee IL,Tamas LB,Nakada T

    更新日期:1991-06-01 00:00:00

  • Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies.

    abstract::MRI of myocardial perfusion observed with an extracellular contrast agent has proven valuable for the detection of coronary artery disease. During contrast enhancement transient dark rim artifacts are sometimes visible, complicating diagnosis and quantification. In this work a quantification of the frequency offsets c...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.21723

    authors: Ferreira P,Gatehouse P,Bucciarelli-Ducci C,Wage R,Firmin D

    更新日期:2008-10-01 00:00:00

  • Fast and accurate measurements of T1 using a multi-readout single inversion-recovery sequence.

    abstract::TOMROP is a multiple readout single inversion-recovery sequence which may potentially allow the measurement of multi-exponential T1 recoveries in vivo by NMR imaging. It is shown that several important modifications must be made to this sequence to permit T1 to be measured accurately and reliably. With these modificat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260109

    authors: Gowland PA,Leach MO

    更新日期:1992-07-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Quantification of regional blood volumes by rapid T1 mapping.

    abstract::A new method is presented for the quantitative determination of regional blood volumes in vivo. It is based on rapid quantitative T1 mapping by Snapshot FLASH MRI combined with the injection of an intravascular MR contrast agent. Regional blood volumes in four different tissues of the rat (skeletal muscle, heart, live...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290521

    authors: Schwarzbauer C,Syha J,Haase A

    更新日期:1993-05-01 00:00:00

  • Modification of embolic-PVA particles with MR contrast agents.

    abstract::We report the synthesis and characterization of polyvinyl alcohol (PVA) embolic particles modified with a clinically approved magnetic resonance (MR) contrast agent. PVA particles are used during transcatheter arterial embolization (TAE) procedures and this minimally invasive technique is a widely employed treatment f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21518

    authors: Cilliers R,Song Y,Kohlmeir EK,Larson AC,Omary RA,Meade TJ

    更新日期:2008-04-01 00:00:00

  • MR microscopy of lung airways with hyperpolarized 3He.

    abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390113

    authors: Chen XJ,Chawla MS,Hedlund LW,Möller HE,MacFall JR,Johnson GA

    更新日期:1998-01-01 00:00:00

  • The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.

    abstract::Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (AC...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22803

    authors: Bauer S,Markl M,Honal M,Jung BA

    更新日期:2011-08-01 00:00:00

  • Manifold Learning in MR spectroscopy using nonlinear dimensionality reduction and unsupervised clustering.

    abstract:PURPOSE:To investigate whether nonlinear dimensionality reduction improves unsupervised classification of (1) H MRS brain tumor data compared with a linear method. METHODS:In vivo single-voxel (1) H magnetic resonance spectroscopy (55 patients) and (1) H magnetic resonance spectroscopy imaging (MRSI) (29 patients) dat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25447

    authors: Yang G,Raschke F,Barrick TR,Howe FA

    更新日期:2015-09-01 00:00:00

  • Per-subject characterization of bolus width in pulsed arterial spin labeling using bolus turbo sampling.

    abstract::Quantification of cerebral blood flow using QUIPSSII pulsed arterial spin labeling requires that the QUIPSS saturation delay TI1 is shorter than the natural temporal bolus width. Yet the duration of the bolus of tagged spins entering the region of interest varies during vasoactive stimuli such as gaseous challenges or...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24412

    authors: Villien M,Chipon E,Troprès I,Bouvier J,Cantin S,Chechin D,Le Bas JF,Krainik A,Warnking JM

    更新日期:2013-06-01 00:00:00

  • Noninvasive analysis of aldose reductase activities in rat testis: 3-FDG NMR spectroscopy and imaging.

    abstract::Noninvasive investigation of aldose reductase activities in rat testis was performed using 3-fluoro-3-deoxy-D-glucose (3-FDG) and nuclear magnetic resonance (NMR) spectroscopy/imaging. Quantitative determination of testis aldose reductase activities, expressed as the sorbitol index, showed a value similar to that of b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290417

    authors: Nakada T,Kwee IL

    更新日期:1993-04-01 00:00:00

  • Sodium imaging of human brain at 7 T with 15-channel array coil.

    abstract::Signal-to-noise ratio (SNR) is a major challenge to sodium magnetic resonance imaging. Phased array coils have been shown significantly improving SNR in proton imaging over volume coils. This study investigates SNR advantage of a 15-channel array head coil (birdcage volume coil for transmit/receive and 15-channel arra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24192

    authors: Qian Y,Zhao T,Wiggins GC,Wald LL,Zheng H,Weimer J,Boada FE

    更新日期:2012-12-01 00:00:00

  • Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI.

    abstract::The properties of the image noise for selective averaging of phase-encoding lines have been investigated. For a given acquisition time, selective averaging results in a signal-to-noise ratio penalty compared to averaging all lines equally. In addition, selective averaging yields a non uniform distribution of noise cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190115

    authors: Mugler JP 3rd

    更新日期:1991-05-01 00:00:00

  • In vivo GABA editing using a novel doubly selective multiple quantum filter.

    abstract::A novel multiple quantum filtering method is proposed that uses a doubly selective pulse termed Delays Alternating with Nutations for Tailored Excitation (DANTE) for multiple quantum preparation. This method selectively prepares GABA-3 and GABA-4 into a multiple quantum state and suppresses all other resonances at 3.0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10104

    authors: Shen J,Rothman DL,Brown P

    更新日期:2002-03-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.

    abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27518

    authors: Meliadò EF,van den Berg CAT,Luijten PR,Raaijmakers AJE

    更新日期:2019-03-01 00:00:00

  • Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters.

    abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25351

    authors: Collier Q,Veraart J,Jeurissen B,den Dekker AJ,Sijbers J

    更新日期:2015-06-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE.

    abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25729

    authors: Rioux JA,Levesque IR,Rutt BK

    更新日期:2016-06-01 00:00:00

  • Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

    abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21194

    authors: Devasahayam N,Subramanian S,Murugesan R,Hyodo F,Matsumoto K,Mitchell JB,Krishna MC

    更新日期:2007-04-01 00:00:00

  • Trace apparent diffusion coefficients of metabolites in human brain using diffusion weighted magnetic resonance spectroscopy.

    abstract::The rotationally invariant trace/3 apparent diffusion coefficients (ADC) of N-acetyl aspartate (NAA), creatine and phosphocreatine (tCr), and choline (Cho) were determined using a diffusion-weighted stimulated echo acquisition mode sequence at 3 T in three separate human brain regions, namely the subcortical white mat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20427

    authors: Ellegood J,Hanstock CC,Beaulieu C

    更新日期:2005-05-01 00:00:00

  • A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

    abstract:PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary func...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24604

    authors: Hamedani H,Kadlecek SJ,Ishii M,Emami K,Kuzma NN,Xin Y,Rossman M,Rizi RR

    更新日期:2013-12-01 00:00:00