Abstract:
PURPOSE:To compare the performance of an 8-channel surface coil/clamshell transmitter and 32-channel head array coil/birdcage transmitter for hyperpolarized 13 C brain metabolic imaging. METHODS:To determine the field homogeneity of the radiofrequency transmitters, B1 + mapping was performed on an ethylene glycol head phantom and evaluated by means of the double angle method. Using a 3D echo-planar imaging sequence, coil sensitivity and noise-only phantom data were acquired with the 8- and 32-channel receiver arrays, and compared against data from the birdcage in transceiver mode. Multislice frequency-specific 13 C dynamic echo-planar imaging was performed on a patient with a brain tumor for each hardware configuration following injection of hyperpolarized [1-13 C]pyruvate. Signal-to-noise ratio (SNR) was evaluated from pre-whitened phantom and temporally summed patient data after coil combination based on optimal weights. RESULTS:The birdcage transmitter produced more uniform B1 + compared with the clamshell: 0.07 versus 0.12 (fractional error). Phantom experiments conducted with matched lateral housing separation demonstrated 8- versus 32-channel mean transceiver-normalized SNR performance: 0.91 versus 0.97 at the head center; 6.67 versus 2.08 on the sides; 0.66 versus 2.73 at the anterior; and 0.67 versus 3.17 on the posterior aspect. While the 8-channel receiver array showed SNR benefits along lateral aspects, the 32-channel array exhibited greater coverage and a more uniform coil-combined profile. Temporally summed, parameter-normalized patient data showed SNRmean,slice ratios (8-channel/32-channel) ranging 0.5-2.00 from apical to central brain. White matter lactate-to-pyruvate ratios were conserved across hardware: 0.45 ± 0.12 (8-channel) versus 0.43 ± 0.14 (32-channel). CONCLUSION:The 8- and 32-channel hardware configurations each have advantages in particular brain anatomy.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Autry AW,Gordon JW,Carvajal L,Mareyam A,Chen HY,Park I,Mammoli D,Vareth M,Chang SM,Wald LL,Xu D,Vigneron DB,Nelson SJ,Li Ydoi
10.1002/mrm.27743subject
Has Abstractpub_date
2019-08-01 00:00:00pages
833-841issue
2eissn
0740-3194issn
1522-2594journal_volume
82pub_type
杂志文章abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26116
更新日期:2017-02-01 00:00:00
abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22415
更新日期:2010-07-01 00:00:00
abstract::Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibrat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22124
更新日期:2009-11-01 00:00:00
abstract::Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculatu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10567
更新日期:2003-09-01 00:00:00
abstract::Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the tec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21245
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:To assess the impact of a different distortion correction (DC) method and patient geometry (sagittal balance) on the quality of spinal cord tractography rendering according to different tractography approaches. METHODS:Forty-four adults free of spinal cord diseases underwent cervical diffusion-weighted imaging...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28665
更新日期:2021-01-21 00:00:00
abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360402
更新日期:1996-10-01 00:00:00
abstract::Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic....
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22162
更新日期:2010-03-01 00:00:00
abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22426
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27464
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26995
更新日期:2018-07-01 00:00:00
abstract::A method is described for multislice imaging by means of rf pulses which contain a multifrequency excitation spectrum. These pulses label each slice by an individual signal phase and allow the separation of the signals from all the slices by subsequent add/subtract procedures. The image sensitivity corresponds to the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060315
更新日期:1988-03-01 00:00:00
abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330209
更新日期:1995-02-01 00:00:00
abstract::Diffusion-weighted single voxel experiments conducted at b-values up to 1 x 10(4) smm-2 yielded biexponential signal attenuation curves for both normal and ischemic brain. The relative fractions of the rapidly and slowly decaying components (f1, f2) are f1 = 0.80 +/- 0.02, f2 = 0.17 +/- 0.02 in healthy adult rat brain...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360607
更新日期:1996-12-01 00:00:00
abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25769
更新日期:2016-06-01 00:00:00
abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290609
更新日期:1993-06-01 00:00:00
abstract::An array of 33 prototype polypeptides was examined as putative contrast agents that can be distinguished from each other based on the chemical exchange saturation transfer (CEST) mechanism. These peptides were chosen based on predictions of the chemical exchange rates of exchangeable amide, amine, and hydroxyl protons...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21683
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:To evaluate the use of variable flip angle refocusing pulse trains in single-shot three-dimensional gradient and spin-echo (3D-GRASE) to reduce blurring and increase the spatial coverage for high spatial resolution T2 -weighted functional MRI at 7 Tesla. METHODS:Variable flip angle refocusing schemes in 3D-GRA...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25979
更新日期:2016-09-01 00:00:00
abstract::Magnetization transfer experiments using an off-resonance irradiation technique were performed on bovine serum albumin solutions by varying the irradiation frequency and the concentration. A transition of the magnetization transfer spectrum from Lorentzian to Gaussian line shape was observed around the critical concen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320406
更新日期:1994-10-01 00:00:00
abstract::For sodium imaging of the human brain, Gibbs' ringing can degrade image appearance and confound image analysis; k-space filtering is generally required. In this work, the signal to noise ratio (SNR) advantage of sampling density weighted apodization (SDWA) over uniform k-space sampling with postacquisition filtering a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21738
更新日期:2008-10-01 00:00:00
abstract::Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion-weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10677
更新日期:2004-01-01 00:00:00
abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21689
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26406
更新日期:2017-08-01 00:00:00
abstract::We describe a doubly tuned radiofrequency (RF) local coil probe designed specifically for performing in vivo image-localized spectroscopy. The probe was designed using principles developed in connection with the counter-rotating-current (CRC) and planar-pair loop gap resonators for magnetic resonance imaging (MRI). Th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060303
更新日期:1988-03-01 00:00:00
abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20450
更新日期:2005-05-01 00:00:00
abstract::We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20439
更新日期:2005-05-01 00:00:00
abstract::The proton exchange rates between water and the hydroxyl protons of threonine, serine, tyrosine, the amino protons of lysine, and the guanidinium protons of arginine were measured in the pH range 0.5 to 8.5 and for the temperatures 4 degrees C, 10 degrees C, 20 degrees C, 30 degrees C, and 36 degrees C. The intrinsic ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350106
更新日期:1996-01-01 00:00:00
abstract::Phase-contrast MRI can provide high-resolution angiographic velocity images, especially in conjunction with non-Cartesian k-space sampling. However, acquisitions can be sensitive to errors from artifacts from main magnetic field inhomogeneities and chemical shift from fat. Particularly in body imaging, fat content can...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22355
更新日期:2010-06-01 00:00:00
abstract::In radiotherapy, target tissues are defined best on MR images due to their superior soft tissue contrast. Computed tomography imaging is geometrically accurate and it is needed for dose calculation and generation of reference images for treatment localization. Co-registration errors between MR and computed tomography ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,随机对照试验
doi:10.1002/mrm.24459
更新日期:2013-07-01 00:00:00
abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24334
更新日期:2013-04-01 00:00:00