Implementation of vascular-space-occupancy MRI at 7T.

Abstract:

:Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and increased contamination from blood-oxygenation-level-dependent (BOLD) effects. In addition, compared to 3T, 7T MRI suffers from increased geometrical distortions, e.g., when using echo-planar-imaging, and from increased power deposition, the latter especially problematic for the spin-echo-train sequences commonly used for VASO MRI. Third, non-steady-state blood spin effects become substantial at 7T when only a head coil is available for radiofrequency transmit. In this study, the magnetization-transfer-enhanced-VASO approach was applied to maximize tissue-blood signal difference, which boosted signal-to-noise ratio by 149% ± 13% (n = 7) compared to VASO. Second, a 3D fast gradient-echo sequence with low flip-angle (7°) and short echo-time (1.8 ms) was used to minimize the BOLD effect and to reduce image distortion and power deposition. Finally, a magnetization-reset technique was combined with a motion-sensitized-driven-equilibrium approach to suppress three types of non-steady-state spins. Our initial functional MRI results in normal human brains at 7T with this optimized VASO sequence showed better signal-to-noise ratio than at 3T.

journal_name

Magn Reson Med

authors

Hua J,Jones CK,Qin Q,van Zijl PC

doi

10.1002/mrm.24334

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

1003-13

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

69

pub_type

杂志文章
  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • MR microimaging of articular cartilage and contrast enhancement by manganese ions.

    abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240114

    authors: Kusaka Y,Gründer W,Rumpel H,Dannhauer KH,Gersonde K

    更新日期:1992-03-01 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T.

    abstract::Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the strength of magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22145

    authors: Weigel M,Helms G,Hennig J

    更新日期:2010-01-01 00:00:00

  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

    abstract:PURPOSE:A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements. THEORY AND METHODS:An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28068

    authors: Cao Z,Yan X,Gore JC,Grissom WA

    更新日期:2020-06-01 00:00:00

  • Boron-11 NMR of borocaptate: relaxation and in vivo detection in melanoma-bearing mice.

    abstract::Longitudinal and transverse relaxation rates for the 11B resonances in sodium borocaptate (BSH) at varying concentrations were measured in undiluted horse serum in a 4.7 Tesla field. The results could be fit by a model that assumes fast exchange of the BSH molecule between a free and a bound state, using values of 0.7...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390314

    authors: Bendel P,Frantz A,Zilberstein J,Kabalka GW,Salomon Y

    更新日期:1998-03-01 00:00:00

  • Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

    abstract::An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal res...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1126

    authors: Panych LP,Zhao L,Jolesz FA,Mulkern RV

    更新日期:2001-06-01 00:00:00

  • Improved data reconstruction method for GRAPPA.

    abstract::This paper presents an improved data reconstruction method for generalized autocalibrating partially parallel acquisitions (GRAPPA) using multicolumn multiline interpolation (MCMLI). Both nearest acquired line (ky) neighboring points and column (kx) neighboring points from all components of an array coil were used to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20601

    authors: Wang Z,Wang J,Detre JA

    更新日期:2005-09-01 00:00:00

  • Saturated double-angle method for rapid B1+ mapping.

    abstract::For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20896

    authors: Cunningham CH,Pauly JM,Nayak KS

    更新日期:2006-06-01 00:00:00

  • Correction of phase errors in quantitative water-fat imaging using a monopolar time-interleaved multi-echo gradient echo sequence.

    abstract:PURPOSE:To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS:A three-step phase correction scheme is proposed to address a) a phase term induce...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26485

    authors: Ruschke S,Eggers H,Kooijman H,Diefenbach MN,Baum T,Haase A,Rummeny EJ,Hu HH,Karampinos DC

    更新日期:2017-09-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.

    abstract:PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24639

    authors: Zong X,Wang P,Kim SG,Jin T

    更新日期:2014-01-01 00:00:00

  • Histogram analysis of the microvasculature of intracerebral human and murine glioma xenografts.

    abstract::The purpose of this study is to examine the usefulness of histogram analysis combined with vessel size index (VSI) magnetic resonance imaging for the specific characterization of brain tumor microvasculature in a panel of six volume-matched glioma xenografts. Using a simple descriptive histogram analysis, significant ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22675

    authors: Just N

    更新日期:2011-03-01 00:00:00

  • Maximum entropy and 2DFT NMR images.

    abstract::A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080310

    authors: De Simone BC,De Luca F,Maraviglia B

    更新日期:1988-11-01 00:00:00

  • Complete elimination of the extracellular 23Na NMR signal in triple quantum filtered spectra of rat hearts in the presence of shift reagents.

    abstract::A method is suggested whereby the shifted extracellular triple quantum filtered 23Na signal of an isolated organ is completely eliminated. The method is based on the long relaxation time of the triple quantum coherence and on its fast evolution rate. When the carrier frequency is set on top of the intracellular sodium...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300415

    authors: Navon G

    更新日期:1993-10-01 00:00:00

  • Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T.

    abstract:PURPOSE:To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS:Measurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequenc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27038

    authors: Jaeschke SHF,Robson MD,Hess AT

    更新日期:2018-08-01 00:00:00

  • B1AC-MAMBA: B1 array combined with multiple-acquisition micro B0 array parallel magnetic resonance imaging.

    abstract::The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10464

    authors: Paley MN,Lee KJ,Wild JM,Fichele S,Whitby EH,Wilkinson ID,Van Beek EJ,Griffiths PD

    更新日期:2003-06-01 00:00:00

  • Analysis by the Carr-Purcell-Meiboom-Gill sequence of the influence of P388 leukemia and of cis-diamminedichloroplatinum(II) nephrotoxicity on water compartmentalization in kidneys and spleens of mice.

    abstract::The multiexponential behavior of the decay curves obtained in vitro by a Carr-Purcell-Meiboom-Gill (CPMG) sequence from spleens and kidneys of mice is analyzed. The mice were inoculated with the acute lymphocytic P388 leukemic cells and treated with the anticancer drug cis-diamminedichloroplatinum(II), cis-Pt. Kidneys...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070408

    authors: François A,Van Gerven L,Atassi G,Eisendrath H,Gielen M,Willem R

    更新日期:1988-08-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Noise removal in magnetic resonance diffusion tensor imaging.

    abstract::Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20582

    authors: Chen B,Hsu EW

    更新日期:2005-08-01 00:00:00

  • Commutator filter: a novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRI.

    abstract::A robust postprocessing method to detect regions of magnetic field change is presented. High resolution gradient echo data is acquired to create a complex baseline image. From this image, two low resolution images are obtained by applying a low pass filter on the magnitude image and the complex image, respectively. Su...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360518

    authors: Lai S,Reichenbach JR,Haacke EM

    更新日期:1996-11-01 00:00:00

  • Robust water fat separated dual-echo MRI by phase-sensitive reconstruction.

    abstract:PURPOSE:The purpose of this work was to develop and evaluate a robust water-fat separation method for T1-weighted symmetric two-point Dixon data. THEORY AND METHODS:A method for water-fat separation by phase unwrapping of the opposite-phase images by phase-sensitive reconstruction (PSR) is introduced. PSR consists of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26488

    authors: Romu T,Dahlström N,Leinhard OD,Borga M

    更新日期:2017-09-01 00:00:00

  • Training a neural network for Gibbs and noise removal in diffusion MRI.

    abstract:PURPOSE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28395

    authors: Muckley MJ,Ades-Aron B,Papaioannou A,Lemberskiy G,Solomon E,Lui YW,Sodickson DK,Fieremans E,Novikov DS,Knoll F

    更新日期:2021-01-01 00:00:00

  • Measurement of 129Xe gas apparent diffusion coefficient anisotropy in an elastase-instilled rat model of emphysema.

    abstract::Hyperpolarized noble gas ((3)He and (129)Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (Δ), and (3)He ADC has been show...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24224

    authors: Boudreau M,Xu X,Santyr GE

    更新日期:2013-01-01 00:00:00

  • Quantitative analysis of the z-spectrum using a numerically simulated look-up table: Application to the healthy human brain at 7T.

    abstract:PURPOSE:To develop a method that fits a multipool model to z-spectra acquired from non-steady state sequences, taking into account the effects of variations in T1 or B1 amplitude and the results estimating the parameters for a four-pool model to describe the z-spectrum from the healthy brain. METHODS:We compared measu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26459

    authors: Geades N,Hunt BAE,Shah SM,Peters A,Mougin OE,Gowland PA

    更新日期:2017-08-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Measurement of perfusion and permeability from dynamic contrast-enhanced MRI in normal and pathological vertebral bone marrow.

    abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22415

    authors: Biffar A,Sourbron S,Schmidt G,Ingrisch M,Dietrich O,Reiser MF,Baur-Melnyk A

    更新日期:2010-07-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00

  • Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

    abstract:PURPOSE:To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS:A metric based on patient-specifi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25366

    authors: Weavers PT,Borisch EA,Riederer SJ

    更新日期:2015-06-01 00:00:00