Abstract:
:For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm(2)) and temporal resolution (∼40 ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our eightfold accelerated real-time cine MRI produced significantly worse qualitative grades (1-5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real-time cine and breath-hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation <10% for left ventricular volumes. Our proposed eightfold accelerated real-time cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim Ddoi
10.1002/mrm.24440subject
Has Abstractpub_date
2013-07-01 00:00:00pages
64-74issue
1eissn
0740-3194issn
1522-2594journal_volume
70pub_type
杂志文章abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370519
更新日期:1997-05-01 00:00:00
abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360617
更新日期:1996-12-01 00:00:00
abstract::Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl carboxylic acid (PCA) through normal and injured kidneys in the living rat. Kidney damage was induced by treatment with 2-bromoethylamine (BEA), which provides a well...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400214
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25147
更新日期:2015-02-01 00:00:00
abstract::The application of spectroscopy techniques to the study of normal and pathological tissue is currently limited by the difficulties of acquiring precisely localized spectra and analyzing the resulting, relatively low signal-to-noise data. Interpretation of multivoxel spectroscopy data is greatly facilitated by estimati...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910250109
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:To develop and validate closed form mathematical expressions that predict the optimal contrast agent concentration for the maximum T1-weighted spoiled gradient echo (SGRE) signal. THEORY AND METHODS:Gadolinium and iron-based contrast agents can have significant transverse relaxivity that leads to signal dropou...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25744
更新日期:2016-04-01 00:00:00
abstract::Proton spin relaxation rate constants in normal and hyponatremic rat brain were measured to determine the sensitivity of metabolite relaxation properties to cytotoxic edema and to quantify metabolite concentration in normal and edematous brain. Relaxation rate constants for protons of water and spectral regions with d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350510
更新日期:1996-05-01 00:00:00
abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390304
更新日期:1998-03-01 00:00:00
abstract::Stejskal and Tanner's ingenious pulsed field gradient design from 1965 has made diffusion NMR and MRI the mainstay of most studies seeking to resolve microstructural information in porous systems in general and biological systems in particular. Methods extending beyond Stejskal and Tanner's design, such as double diff...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,评审
doi:10.1002/mrm.25901
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS:A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27705
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:High-resolution three-dimensional (3D) structural MRI is useful for delineating complex or small structures of the body. However, it requires long acquisition times and high SAR, limiting its clinical use. The purpose of this work is to accelerate the acquisition of high-resolution images by combining compresse...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27789
更新日期:2019-09-01 00:00:00
abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300210
更新日期:1993-08-01 00:00:00
abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030221
更新日期:1986-04-01 00:00:00
abstract:PURPOSE:To develop a method for retrospective artifact elimination of MRS data. This retrospective method was based on an approach that combines jackknife analyses with the correlation of spectral windows, and therefore termed "JKC." METHODS:Twelve healthy volunteers performed 3 separate measurement protocols using a ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27590
更新日期:2019-04-01 00:00:00
abstract::When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21959
更新日期:2009-05-01 00:00:00
abstract::The somatotopical organization of the human somatosensory cortex was analyzed with echo-planar imaging at 1.5 Tesla, utilizing deoxyhemoglobin as an endogenous contrast medium. Scrubbing stimulation at a frequency of 3 Hz was applied to one of three cutaneous areas: toes, fingertips, and tongue tip. Parasagittal echo-...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330521
更新日期:1995-05-01 00:00:00
abstract::High-quality, high-resolution, proton-decoupled natural-abundance 13C NMR spectra have been obtained in vitro at 100.6 MHz from unprocessed human pathology specimens of tumors and adjacent nonneoplastic control tissues from lung, colon, and prostate. In these preliminary studies, specific molecular parameters were ide...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910070403
更新日期:1988-08-01 00:00:00
abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28620
更新日期:2020-12-13 00:00:00
abstract:PURPOSE:Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24829
更新日期:2014-05-01 00:00:00
abstract::A method for the acquisition of localized 2D shift-correlated spectra, based on the combination of the stimulated-echo volume-selection and gradient-enhanced COSY experiments, is described. The sequence can be modified to perform a number of localized experiments including HOHAHA and DQF-COSY. The method is demonstrat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320216
更新日期:1994-08-01 00:00:00
abstract::A novel radio-frequency (RF) pulse design algorithm is presented that generates fast slice-selective excitation pulses that mitigate B+1 inhomogeneity present in the human brain at high field. The method is provided an estimate of the B+1 field in an axial slice of the brain and then optimizes the placement of sinc-li...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21585
更新日期:2008-06-01 00:00:00
abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25729
更新日期:2016-06-01 00:00:00
abstract::The recently developed technique of gradient, high-resolution magic-angle spinning NMR (g-hr-MAS-NMR) spectroscopy was applied to the study of ex vivo human lipoma and liposarcoma tissue. Compared with conventional 1H-NMR, the g-hr-MAS method yielded a large improvement in spectral resolution and permitted the detecti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380307
更新日期:1997-09-01 00:00:00
abstract::Chemical shifts were extracted from in vivo 3-dimensional 31P NMR CSI data and pH images were constructed. The images could spatially resolve tissue pH ranging from 5.8 to 7.2 (with uncertainty of 0.11-0.17 pH unit) in an ischemia-reperfusion model of diabetic rat calf muscles. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290214
更新日期:1993-02-01 00:00:00
abstract::In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>
更新日期:2000-04-01 00:00:00
abstract::Quantitative 1H MRS to determine cerebral metabolite patterns and MRI to determine CSF flow were applied to 12 patients with ventricular dilation-Group A, cortical atrophy (N = 5); or Group B, hydrocephalus (N = 7)- and in 9 normal controls. While mean brain water (Group A = 80% +/- 6; Group B = 86% +/- 5; normal = 85...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370317
更新日期:1997-03-01 00:00:00
abstract:PURPOSE:Fourier decomposition (FD) is a noninvasive method for assessing ventilation and perfusion-related information in the lungs. However, the technique has a low signal-to-noise ratio (SNR) in the lung parenchyma. We present an approach to increase the SNR in both morphological and functional images. METHODS:The d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25293
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:We aimed to develop a novel free-breathing cardiac diffusion tensor MRI (DT-MRI) approach, M2-MT-MOCO, capable of whole left ventricular coverage that leverages second-order motion compensation (M2) diffusion encoding and multitasking (MT) framework to efficiently correct for respiratory motion (MOCO). METHODS...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28611
更新日期:2020-11-30 00:00:00
abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290609
更新日期:1993-06-01 00:00:00
abstract::Using a 32-echo imaging pulse sequence, T2 relaxation decay curves were acquired from five white- and six gray-matter brain structures outlined in 12 normal volunteers. The water contents of white and gray matter were 0.71 (0.01) and 0.83 (0.03) g/ml, respectively. All white-matter structures had significantly higher ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370107
更新日期:1997-01-01 00:00:00