Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

Abstract:

:When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the subsequent large-scale signal change that occurs in the arteries. However, little work has been carried out to quantify the sensitivity of tracer kinetic modeling parameters to the form of AIF. Using a preclinical experimental data set, we sought to measure the effect of varying model forms of AIF on the extended Kety compartmental model parameters (K(trans), v(e), and v(p)) through comparison with the results of experimentally acquired high temporal resolution AIFs. The AIF models examined have the potential to be parameterized on lower temporal resolution data to predict the form of the true, higher temporal resolution AIF. The models were also evaluated through application to the population average AIF. It was concluded that, in the instance of low temporal resolution or noisy data, it may be preferable to use a bi-exponential model applied to the raw data AIF, or when individual measurements are not available a bi-exponential model of the average AIF.

journal_name

Magn Reson Med

authors

McGrath DM,Bradley DP,Tessier JL,Lacey T,Taylor CJ,Parker GJ

doi

10.1002/mrm.21959

subject

Has Abstract

pub_date

2009-05-01 00:00:00

pages

1173-84

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

61

pub_type

杂志文章
  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • Determination of the optimal first-order gradient moment for flow-sensitive dephasing magnetization-prepared 3D noncontrast MR angiography.

    abstract::Flow-sensitive dephasing (FSD) magnetization preparation has been developed for black-blood vessel wall MRI and noncontrast MR angiography. The first-order gradient moment, m(1) , is a measure of the flow-sensitization imparted by an FSD preparative module. Determination of the optimal m(1) for each individual is high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22847

    authors: Fan Z,Zhou X,Bi X,Dharmakumar R,Carr JC,Li D

    更新日期:2011-04-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • New double quantum coherence filter for localized detection of glutathione in vivo.

    abstract::In this work, a new double quantum filter for glutathione (GSH) editing is introduced, combined with the point-resolved spectroscopy localization sequence (PRESS), and demonstrated in vivo. Compared to the conventional double quantum coherence filter, the new filter has two major advantages. First, it eliminates the n...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20788

    authors: Zhao T,Heberlein K,Jonas C,Jones DP,Hu X

    更新日期:2006-03-01 00:00:00

  • 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25840

    authors: Oezerdem C,Winter L,Graessl A,Paul K,Els A,Weinberger O,Rieger J,Kuehne A,Dieringer M,Hezel F,Voit D,Frahm J,Niendorf T

    更新日期:2016-06-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Identification of different lipid phases and calcium phosphate deposits in human carotid artery plaques by MAS NMR spectroscopy.

    abstract::Accumulation of lipids in atherosclerotic plaques causes progressive narrowing of the arterial lumen, often followed by thrombosis and ischemia. Currently several different methods, most requiring disruption of the plaque, are used to study the physical properties of lipids accumulated in plaques, and lipid compositio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390204

    authors: Guo W,Morrisett JD,Lawrie GM,DeBakey ME,Hamilton JA

    更新日期:1998-02-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00

  • A versatile multinuclear probe designed for in vivo NMR spectroscopy: applications to subcutaneous human tumors in mice.

    abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060102

    authors: Lyon RC,Tschudin RG,Daly PF,Cohen JS

    更新日期:1988-01-01 00:00:00

  • Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRI.

    abstract::Diffusion-weighted MRI is a clinically useful technique, but its utility is compromised by high sensitivity to patient motion. Use of radial-scan data acquisition and projection reconstruction, rather than the conventional Fourier imaging method, can substantially reduce the sensitivity to global translational motion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290619

    authors: Gmitro AF,Alexander AL

    更新日期:1993-06-01 00:00:00

  • Proton high-resolution magic angle spinning NMR analysis of fresh and previously frozen tissue of human prostate.

    abstract::The previously observed improvement in spectral resolution of tissue proton NMR with high-resolution magic angle spinning (HRMAS) was speculated to be due largely to freeze-thawing artifacts resulting from tissue storage. In this study, 12 human prostate samples were analyzed on a 14.1T spectrometer at 3 degrees C, wi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10645

    authors: Wu CL,Taylor JL,He W,Zepeda AG,Halpern EF,Bielecki A,Gonzalez RG,Cheng LL

    更新日期:2003-12-01 00:00:00

  • Quantitative framework for prospective motion correction evaluation.

    abstract:PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns betw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25580

    authors: Pannetier NA,Stavrinos T,Ng P,Herbst M,Zaitsev M,Young K,Matson G,Schuff N

    更新日期:2016-02-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • 4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS).

    abstract::Coronary artery data acquisition with steady-state free precession (SSFP) is typically performed in a single frame in mid-diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient respons...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20627

    authors: Park J,Larson AC,Zhang Q,Simonetti O,Li D

    更新日期:2005-10-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00

  • Direct reconstruction of MR images from data acquired on a non-Cartesian grid using an equal-phase-line algorithm.

    abstract::The equal-phase line (EPL) algorithm is proposed as a means of allowing rapid Fourier transform (FT) reconstruction of MR image data acquired on a non-Cartesian grid. The pixels on the image are grouped according to their positions. The pixels in a group have the same phase in the complex exponential function -exp[j2p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10165

    authors: Qian Y,Lin J,Jin D

    更新日期:2002-06-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • Perfusion mapping with multiecho multishot parallel imaging EPI.

    abstract::Echo-planar imaging (EPI) is the standard technique for dynamic susceptibility-contrast (DSC) perfusion MRI. However, EPI suffers from well-known geometric distortions, which can be reduced by increasing the k-space phase velocity. Moreover, the long echo times (TEs) used in DSC lead to signal saturation of the arteri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21255

    authors: Newbould RD,Skare ST,Jochimsen TH,Alley MT,Moseley ME,Albers GW,Bammer R

    更新日期:2007-07-01 00:00:00

  • Multislice and multicoil phase-sensitive inversion-recovery imaging.

    abstract::Phase-sensitive inversion-recovery (PSIR) imaging may provide enhanced T(1) contrast. However, clinical implementation of PSIR imaging is hindered because image reconstruction with this method often lacks robustness and requires manual intervention, particularly for data acquired in multiple slices and with phased-arr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20414

    authors: Ma J

    更新日期:2005-04-01 00:00:00

  • Template-based field map prediction for rapid whole brain B0 shimming.

    abstract:PURPOSE:In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. METHODS:The template-based prediction method uses prior knowledge of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27020

    authors: Shi Y,Vannesjo SJ,Miller KL,Clare S

    更新日期:2018-07-01 00:00:00

  • Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy.

    abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24129

    authors: Keating B,Ernst T

    更新日期:2012-11-01 00:00:00

  • Q-space truncation and sampling in diffusion spectrum imaging.

    abstract:PURPOSE:To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS:DSI data were acquired using the MGH-USC connectome scanner (Gmax  = 300 mT/m) with bmax  = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 gri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26071

    authors: Tian Q,Rokem A,Folkerth RD,Nummenmaa A,Fan Q,Edlow BL,McNab JA

    更新日期:2016-12-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

    abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26116

    authors: Poulsen C,Wakeman DG,Atefi SR,Luu P,Konyn A,Bonmassar G

    更新日期:2017-02-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Design of adiabatic selective pulses using optimal control theory.

    abstract::Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. "Minimum distance" was the main formulation used for the solution. Because of their robust...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360311

    authors: Rosenfeld D,Zur Y

    更新日期:1996-09-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00