Multislice and multicoil phase-sensitive inversion-recovery imaging.

Abstract:

:Phase-sensitive inversion-recovery (PSIR) imaging may provide enhanced T(1) contrast. However, clinical implementation of PSIR imaging is hindered because image reconstruction with this method often lacks robustness and requires manual intervention, particularly for data acquired in multiple slices and with phased-array coils. In this paper, a new algorithm suitable for automatic PSIR image reconstruction of multislice and multicoil data is presented. This algorithm phase corrects by region-growing, employing both the magnitude and the phase information of image pixels. Specifically, phase gradients of the original complex image are first calculated and then used to determine the sequence of the region-growing. The signal direction relating to the phase error for each pixel is then determined during the region-growing using both the magnitude and the phase of the previously determined pixels that are located within a boxcar neighborhood of the pixel. Finally, the intrinsic intercoil and interslice correlation is exploited to ensure consistency in the global polarity of all of the PSIR images. The results are demonstrated with in vivo human brain images acquired at 3 Tesla with an eight-channel phased-array coil.

journal_name

Magn Reson Med

authors

Ma J

doi

10.1002/mrm.20414

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

904-10

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

53

pub_type

杂志文章
  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Myocardial T2* mapping free of distortion using susceptibility-weighted fast spin-echo imaging: a feasibility study at 1.5 T and 3.0 T.

    abstract::This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T2* mapping of the heart. First, T2* maps are presented for oil phantoms ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22054

    authors: Heinrichs U,Utting JF,Frauenrath T,Hezel F,Krombach GA,Hodenius MA,Kozerke S,Niendorf T

    更新日期:2009-09-01 00:00:00

  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

    abstract:PURPOSE:A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements. THEORY AND METHODS:An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28068

    authors: Cao Z,Yan X,Gore JC,Grissom WA

    更新日期:2020-06-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • Estimating T1 from multichannel variable flip angle SPGR sequences.

    abstract::Quantitative estimation of T1 is a challenging but important task inherent to many clinical applications. The most commonly used paradigm for estimating T1 in vivo involves performing a sequence of spoiled gradient-recalled echo acquisitions at different flip angles, followed by fitting of an exponential model to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24401

    authors: Trzasko JD,Mostardi PM,Riederer SJ,Manduca A

    更新日期:2013-06-01 00:00:00

  • Analysis by the Carr-Purcell-Meiboom-Gill sequence of the influence of P388 leukemia and of cis-diamminedichloroplatinum(II) nephrotoxicity on water compartmentalization in kidneys and spleens of mice.

    abstract::The multiexponential behavior of the decay curves obtained in vitro by a Carr-Purcell-Meiboom-Gill (CPMG) sequence from spleens and kidneys of mice is analyzed. The mice were inoculated with the acute lymphocytic P388 leukemic cells and treated with the anticancer drug cis-diamminedichloroplatinum(II), cis-Pt. Kidneys...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070408

    authors: François A,Van Gerven L,Atassi G,Eisendrath H,Gielen M,Willem R

    更新日期:1988-08-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

    abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>

    authors: Afeworki M,van Dam GM,Devasahayam N,Murugesan R,Cook J,Coffin D,Larsen JH,Mitchell JB,Subramanian S,Krishna MC

    更新日期:2000-03-01 00:00:00

  • Tuning and amplification strategies for intravascular imaging coils.

    abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24134

    authors: Yak N,Anderson KJ,Wright GA

    更新日期:2012-11-01 00:00:00

  • Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

    abstract:PURPOSE:To develop velocity-selective (VS) MR angiography (MRA) protocols for arteriography and venography with whole-brain coverage. METHODS:Tissue suppression using velocity-selective saturation (VSS) pulse trains is sensitive to radiofrequency field (B1 +) inhomogeneity. To reduce its sensitivity, we replaced the l...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26864

    authors: Li W,Xu F,Schär M,Liu J,Shin T,Zhao Y,van Zijl PCM,Wasserman BA,Qiao Y,Qin Q

    更新日期:2018-04-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • Quantitative transport mapping (QTM) of the kidney with an approximate microvascular network.

    abstract:PURPOSE:Proof-of-concept study of mapping renal blood flow vector field according to the inverse solution to a mass transport model of time resolved tracer-labeled MRI data. THEORY AND METHODS:To determine tissue perfusion according to the underlying physics of spatiotemporal tracer concentration variation, the mass t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28584

    authors: Zhou L,Zhang Q,Spincemaille P,Nguyen TD,Morgan J,Dai W,Li Y,Gupta A,Prince MR,Wang Y

    更新日期:2021-04-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

    abstract:PURPOSE:To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS:A homogeneous phantom and five healthy voluntee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27750

    authors: Poblador Rodriguez E,Moser P,Dymerska B,Robinson S,Schmitt B,van der Kouwe A,Gruber S,Trattnig S,Bogner W

    更新日期:2019-08-01 00:00:00

  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations.

    abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26333

    authors: McGrath DM,Ravikumar N,Beltrachini L,Wilkinson ID,Frangi AF,Taylor ZA

    更新日期:2017-07-01 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

    abstract::High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24176

    authors: Teeuwisse WM,Brink WM,Haines KN,Webb AG

    更新日期:2012-04-01 00:00:00

  • Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

    abstract:PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25635

    authors: Ma C,Lam F,Johnson CL,Liang ZP

    更新日期:2016-02-01 00:00:00

  • Multiecho segmented EPI with z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI.

    abstract::A MultiEcho Segmented EPI with z-shimmed BAckground gradient Compensation (MESBAC) pulse sequence is proposed and validated for functional MRI (fMRI) study in regions suffering from severe susceptibility artifacts. This sequence provides an effective tradeoff between spatial and temporal resolution and reduces image d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10219

    authors: Li Z,Wu G,Zhao X,Luo F,Li SJ

    更新日期:2002-08-01 00:00:00

  • Quantification of the pulse wave velocity of the descending aorta using axial velocity profiles from phase-contrast magnetic resonance imaging.

    abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21034

    authors: Yu HY,Peng HH,Wang JL,Wen CY,Tseng WY

    更新日期:2006-10-01 00:00:00

  • Rapid and motion-robust volume coverage using cross-sectional real-time MRI.

    abstract:PURPOSE:To develop a rapid and motion-robust technique for volumetric MRI, which is based on cross-sectional real-time MRI acquisitions with automatic advancement of the slice position. METHODS:Real-time MRI with a frame-by-frame moving cross-section is performed with use of highly undersampled radial gradient-echo se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28029

    authors: Voit D,Kalentev O,van Zalk M,Joseph AA,Frahm J

    更新日期:2020-05-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • Flexible and efficient optimization of quantitative sequences using automatic differentiation of Bloch simulations.

    abstract:PURPOSE:To investigate a computationally efficient method for optimizing the Cramér-Rao Lower Bound (CRLB) of quantitative sequences without using approximations or an analytical expression of the signal. METHODS:Automatic differentiation was applied to Bloch simulations and used to optimize several quantitative seque...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27832

    authors: Lee PK,Watkins LE,Anderson TI,Buonincontri G,Hargreaves BA

    更新日期:2019-10-01 00:00:00

  • Multispectral imaging with three-dimensional rosette trajectories.

    abstract::Two-dimensional intersecting k-space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k-space points leads to destructive interference of the signal coming from the off-resonance spectral peaks; on-resonance data reconstruction yields images of the on-resonance p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21551

    authors: Bucholz EK,Song J,Johnson GA,Hancu I

    更新日期:2008-03-01 00:00:00

  • The fast spiral-SelMQC technique for in vivo MR spectroscopic imaging of polyunsaturated fatty acids in human breast tissue.

    abstract::The selective multiple-quantum coherence transfer method has been applied to image polyunsaturated fatty acids (PUFA) distributions in human breast tissues in vivo for cancer detection, with complete suppression of the unwanted lipid and water signals in a single scan. The Cartesian k-space mapping of PUFA in vivo usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22901

    authors: Zhu H,Rubin D,He Q

    更新日期:2012-01-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00