Analysis by the Carr-Purcell-Meiboom-Gill sequence of the influence of P388 leukemia and of cis-diamminedichloroplatinum(II) nephrotoxicity on water compartmentalization in kidneys and spleens of mice.

Abstract:

:The multiexponential behavior of the decay curves obtained in vitro by a Carr-Purcell-Meiboom-Gill (CPMG) sequence from spleens and kidneys of mice is analyzed. The mice were inoculated with the acute lymphocytic P388 leukemic cells and treated with the anticancer drug cis-diamminedichloroplatinum(II), cis-Pt. Kidneys and spleens of control animals display four relaxation components. The two longest ones were assigned, in the kidneys, in decreasing order of their relaxation time value, to intracellular and extracellular water, respectively. In spleens, the reversed assignment resulted. The two shortest ones are assigned to different tightly bound hydration water compartments, the fastest relaxing one being more greatly influenced by the unobservable crystalline water. No significant systemic effect on the intra- and extracellular water relaxation times could be observed in the kidneys under P388 leukemia inoculation, despite an apparent increase in the intracellular water content. In contrast, drug administration results in the apparent decrease in or even disappearance of the extracellular water component, with an increase in both relaxation time and apparent fraction of the intracellular water. These effects correlate well with changes in the usual nephrotoxicity parameters and are explained in terms of the well-known cell damage in kidneys under cis-platinum administration. A systemic effect under P388 leukemia disease is observed for the spleen, resulting again in the disappearance of the extracellular water component. The latter is related to splenomegaly due to invasion of the organ by leukemic cells during disease development.

journal_name

Magn Reson Med

authors

François A,Van Gerven L,Atassi G,Eisendrath H,Gielen M,Willem R

doi

10.1002/mrm.1910070408

subject

Has Abstract

pub_date

1988-08-01 00:00:00

pages

449-62

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

7

pub_type

杂志文章
  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field.

    abstract:PURPOSE:To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS:A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding wa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26263

    authors: Castets CR,Lefrançois W,Wecker D,Ribot EJ,Trotier AJ,Thiaudière E,Franconi JM,Miraux S

    更新日期:2017-05-01 00:00:00

  • Intensity correction for multichannel hyperpolarized 13C imaging of the heart.

    abstract:PURPOSE:Develop and test an analytic correction method to correct the signal intensity variation caused by the inhomogeneous reception profile of an eight-channel phased array for hyperpolarized (13) C imaging. THEORY AND METHODS:Fiducial markers visible in anatomical images were attached to the individual coils to pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26042

    authors: Dominguez-Viqueira W,Geraghty BJ,Lau JY,Robb FJ,Chen AP,Cunningham CH

    更新日期:2016-02-01 00:00:00

  • Low-rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging.

    abstract:PURPOSE:To improve multichannel compressed sensing (CS) reconstruction for MR proton resonance frequency (PRF) shift thermography, with application to MRI-induced RF heating evaluation and MR guided high intensity focused ultrasound (MRgFUS) temperature monitoring. METHODS:A new compressed sensing reconstruction is pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27666

    authors: Cao Z,Gore JC,Grissom WA

    更新日期:2019-06-01 00:00:00

  • Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

    abstract:PURPOSE:We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion-weighted imaging (DWI). METHODS:First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction alg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25318

    authors: Chang HC,Guhaniyogi S,Chen NK

    更新日期:2015-05-01 00:00:00

  • Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

    abstract::Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27742

    authors: Wilson M,Andronesi O,Barker PB,Bartha R,Bizzi A,Bolan PJ,Brindle KM,Choi IY,Cudalbu C,Dydak U,Emir UE,Gonzalez RG,Gruber S,Gruetter R,Gupta RK,Heerschap A,Henning A,Hetherington HP,Huppi PS,Hurd RE,Kantarci K,Ka

    更新日期:2019-08-01 00:00:00

  • Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises.

    abstract:PURPOSE:To develop and test real-time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. METHODS:In 15 healthy participants, 6 groups of lower-leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28095

    authors: Schrank F,Warmuth C,Görner S,Meyer T,Tzschätzsch H,Guo J,Uca YO,Elgeti T,Braun J,Sack I

    更新日期:2020-07-01 00:00:00

  • Magnesium and pH imaging of the human brain at 3.0 Tesla.

    abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26

    authors: Barker PB,Butterworth EJ,Boska MD,Nelson J,Welch KM

    更新日期:1999-02-01 00:00:00

  • Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: in vivo validation in the porcine aorta.

    abstract::Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20137

    authors: Draney MT,Arko FR,Alley MT,Markl M,Herfkens RJ,Pelc NJ,Zarins CK,Taylor CA

    更新日期:2004-08-01 00:00:00

  • Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

    abstract:PURPOSE:To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY:The proposed technique exploits the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26076

    authors: Wang Y,Shao X,Martin T,Moeller S,Yacoub E,Wang DJ

    更新日期:2016-12-01 00:00:00

  • Volumetric navigators for real-time motion correction in diffusion tensor imaging.

    abstract::Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel techn...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23314

    authors: Alhamud A,Tisdall MD,Hess AT,Hasan KM,Meintjes EM,van der Kouwe AJ

    更新日期:2012-10-01 00:00:00

  • Quantification of the extraction fraction for gadopentetate across breast cancer capillaries.

    abstract::To quantify the extraction fraction, E, for gadopentetate across tumor capillaries, R3230 adenocarcinomas were implanted in the mammary fat pads of seven rats. The value of E was determined by using a two-compartment tissue model in which the endothelial transfer coefficient, K(PS) (ml x min(-1) x cc(-1) of tissue), w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400406

    authors: Daldrup HE,Shames DM,Husseini W,Wendland MF,Okuhata Y,Brasch RC

    更新日期:1998-10-01 00:00:00

  • Fast gated EPR imaging of the beating heart: spatiotemporally resolved 3D imaging of free-radical distribution during the cardiac cycle.

    abstract::In vivo or ex vivo electron paramagnetic resonance imaging (EPRI) is a powerful technique for determining the spatial distribution of free radicals and other paramagnetic species in living organs and tissues. However, applications of EPRI have been limited by long projection acquisition times and the consequent fact t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24250

    authors: Chen Z,Reyes LA,Johnson DH,Velayutham M,Yang C,Samouilov A,Zweier JL

    更新日期:2013-02-01 00:00:00

  • SLIP, a lipid suppression technique to improve image contrast in inflow angiography.

    abstract::In rapidly acquired gradient echo images, lipid regions usually appear as areas of high signal intensity. In 2D inflow angiograms processed by the maximum intensity projection algorithm, this high lipid signal may prevent angiographic visualization of some blood vessels. We present a new approach to suppress the lipid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210110

    authors: Doyle M,Matsuda T,Pohost GM

    更新日期:1991-09-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • Electromagnetic actuator for generating variably oriented shear waves in MR elastography.

    abstract::Magnetic resonance elastography (MRE) is a recently developed technique for determining the mechanical properties of biological tissue. In dynamic MRE, electromagnetic units (actuators) are widely used to generate shear waves in tissue. These actuators exploit the interaction between the static magnetic field B(0) and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10479

    authors: Braun J,Braun K,Sack I

    更新日期:2003-07-01 00:00:00

  • Radial single-shot STEAM MRI.

    abstract::Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21401

    authors: Block KT,Frahm J

    更新日期:2008-04-01 00:00:00

  • Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T.

    abstract::Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the strength of magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22145

    authors: Weigel M,Helms G,Hennig J

    更新日期:2010-01-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • In vivo waveguide elastography: effects of neurodegeneration in patients with amyotrophic lateral sclerosis.

    abstract:PURPOSE:Waveguide elastography (WGE) combines magnetic resonance elastography (MRE), diffusion tensor imaging (DTI), and anisotropic inversions for a determination of the elastic properties of white matter. Previously, the method evaluated the anisotropic elastic properties of the corticospinal tracts (CSTs) of healthy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25067

    authors: Romano A,Guo J,Prokscha T,Meyer T,Hirsch S,Braun J,Sack I,Scheel M

    更新日期:2014-12-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Fat-suppressed alternating-SSFP for whole-brain fMRI using breath-hold and visual stimulus paradigms.

    abstract:PURPOSE:To achieve artifact-suppressed whole-brain pass-band-balanced steady-state free precession functional MRI from a single functional magnetic resonance imaging (fMRI) scan. METHODS:A complete and practical data acquisition sequence for alt-SSFP fMRI was developed. First, multishot flyback-echo-planar imaging (EP...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25797

    authors: Jou T,Patterson S,Pauly JM,Bowen CV

    更新日期:2016-05-01 00:00:00

  • Off-resonance effects in the transient response of SSFP sequences.

    abstract::A previously developed eigenvector formalism is adapted to off-resonance in the transient response of quasiperiodic steady-state free precession (SSFP) sequences, including TrueFISP as a special case. The effective relaxation rates for essentially parallel and perpendicular deviations from the steady state are determi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20173

    authors: Ganter C

    更新日期:2004-08-01 00:00:00

  • Toward fully automatic estimation of in vivo 31P spectra.

    abstract::Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation metho...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210206

    authors: Burger C,McKinnon G,Buchli R,Boesiger P

    更新日期:1991-10-01 00:00:00

  • High-resolution 1 H-MRSI of the brain using short-TE SPICE.

    abstract:PURPOSE:To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS:The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26130

    authors: Ma C,Lam F,Ning Q,Johnson CL,Liang ZP

    更新日期:2017-02-01 00:00:00

  • Echo-planar spin-echo and inversion pulses.

    abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290609

    authors: Pauly J,Spielman D,Macovski A

    更新日期:1993-06-01 00:00:00

  • Diffusion-weighted imaging of the human optic nerve: a new approach to evaluate optic neuritis in multiple sclerosis.

    abstract::The apparent diffusion coefficient (ADC) in the optic nerve was measured from diffusion-weighted magnetic resonance imaging using an intravoxel incoherent motion (IVIM) sequence. The subjects were seven normal volunteers and eight patients with multiple sclerosis (MS) with a total of four optic nerves with acute neuri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380317

    authors: Iwasawa T,Matoba H,Ogi A,Kurihara H,Saito K,Yoshida T,Matsubara S,Nozaki A

    更新日期:1997-09-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00