Volumetric navigators for real-time motion correction in diffusion tensor imaging.

Abstract:

:Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the contrast is independent of the b-value, to perform prospective motion correction in diffusion weighted images, without having to reacquire volumes during which motion occurred, unless motion exceeded some preset thresholds. Water phantom and human brain data were acquired using the standard and navigated diffusion sequences, and the mean and whole brain histogram of the fractional anisotropy and mean diffusivity were analyzed. Our results show that adding the navigator does not influence the diffusion sequence. With head motion, the whole brain histogram-fractional anisotropy shows a shift toward lower anisotropy with a significant decrease in both the mean fractional anisotropy and the fractional anisotropy histogram peak location (P<0.01), whereas the whole brain histogram-mean diffusivity shows a shift toward higher diffusivity with a significant increase in the mean diffusivity (P<0.01), even after retrospective motion correction. These changes in the mean and the shape of the histograms are recovered substantially in the prospective motion corrected data acquired using the navigated sequence.

journal_name

Magn Reson Med

authors

Alhamud A,Tisdall MD,Hess AT,Hasan KM,Meintjes EM,van der Kouwe AJ

doi

10.1002/mrm.23314

subject

Has Abstract

pub_date

2012-10-01 00:00:00

pages

1097-108

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

68

pub_type

杂志文章
  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • S5FP: spectrally selective suppression with steady state free precession.

    abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20633

    authors: Derbyshire JA,Herzka DA,McVeigh ER

    更新日期:2005-10-01 00:00:00

  • Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals.

    abstract:PURPOSE:To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component. METHODS:Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and addit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26819

    authors: Levine E,Stevens K,Beaulieu C,Hargreaves B

    更新日期:2018-03-01 00:00:00

  • Fe(III) distribution varies substantially within and between atherosclerotic plaques.

    abstract:PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24687

    authors: Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

    更新日期:2014-02-01 00:00:00

  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • The effect of realistic geometries on the susceptibility-weighted MR signal in white matter.

    abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26689

    authors: Xu T,Foxley S,Kleinnijenhuis M,Chen WC,Miller KL

    更新日期:2018-01-01 00:00:00

  • Murine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI.

    abstract::High-field MRI scanners are, in principle, well suited for mouse studies; however, many high-field magnets employ a vertical design that may influence the physiological state of the rodent. The purpose of this study was to investigate the orthostatic response of cerebral blood flow (CBF) in mice during a prolonged MR ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20621

    authors: Foley LM,Hitchens TK,Kochanek PM,Melick JA,Jackson EK,Ho C

    更新日期:2005-10-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

    abstract::An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal res...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1126

    authors: Panych LP,Zhao L,Jolesz FA,Mulkern RV

    更新日期:2001-06-01 00:00:00

  • Robust 4D flow denoising using divergence-free wavelet transform.

    abstract:PURPOSE:To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS:DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25176

    authors: Ong F,Uecker M,Tariq U,Hsiao A,Alley MT,Vasanawala SS,Lustig M

    更新日期:2015-02-01 00:00:00

  • Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

    abstract:PURPOSE:The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 imperfections, which are two main factors that affect quantitative results in MRF. METHODS:The SP and B1 imperfections are characterized and correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26580

    authors: Ma D,Coppo S,Chen Y,McGivney DF,Jiang Y,Pahwa S,Gulani V,Griswold MA

    更新日期:2017-11-01 00:00:00

  • Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

    abstract:PURPOSE:To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. THEORY AND METHODS:Multispectral imaging (MSI) techniques perform time-consuming independent three-dimensional acquisitions with varying radio freq...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25087

    authors: Smith MR,Artz NS,Koch KM,Samsonov A,Reeder SB

    更新日期:2014-12-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • A three-dimensional variable-density spiral spatial-spectral RF pulse with rotated gradients.

    abstract::Three-dimensional spatial-spectral radiofrequency pulses using a stack-of-spirals trajectory can achieve two-dimensional spatial localization and one-dimensional spectral selection simultaneously. These pulses are useful, for example, in reduced field-of-view applications that also require frequency specificity such a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22209

    authors: Deng W,Stenger VA

    更新日期:2010-03-01 00:00:00

  • High-resolution 1 H-MRSI of the brain using short-TE SPICE.

    abstract:PURPOSE:To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS:The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26130

    authors: Ma C,Lam F,Ning Q,Johnson CL,Liang ZP

    更新日期:2017-02-01 00:00:00

  • Evaluation of coils for imaging histological slides: signal-to-noise ratio and filling factor.

    abstract:PURPOSE:To investigate the relative gain in sensitivity of five histology coils designed in-house to accommodate tissue sections of various sizes and compare with commercial mouse head coils. METHODS:The coil set was tailored to house tissue sections ranging from 5 to1000 µm encased in either glass slides or coverslip...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24841

    authors: Hoang DM,Voura EB,Zhang C,Fakri-Bouchet L,Wadghiri YZ

    更新日期:2014-05-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • Theory of heterogeneous relaxation in compartmentalized tissues.

    abstract::A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370507

    authors: Barsky D,Pütz B,Schulten K

    更新日期:1997-05-01 00:00:00

  • Radiofrequency pulse design for the selective excitation of dissolved 129Xe.

    abstract:PURPOSE:To optimize radiofrequency (RF) pulses for the selective excitation of dissolved phase (129)Xe that take into account the very short T2*, while simultaneously, minimally exciting the much larger gas signal. METHODS:Numerical simulations of Shinnar le-Roux pulses and binomial coefficient composite-element pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25089

    authors: Leung G,Norquay G,Schulte RF,Wild JM

    更新日期:2015-01-01 00:00:00

  • Prospective GIRF-based RF phase cycling to reduce eddy current-induced steady-state disruption in bSSFP imaging.

    abstract:PURPOSE:To propose an explicit Balanced steady-state free precession (bSSFP) signal model that predicts eddy current-induced steady-state disruptions and to provide a prospective, practical, and general eddy current compensation method. THEORY AND METHODS:Gradient impulse response functions (GIRF) were used to simulat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28097

    authors: Bruijnen T,Stemkens B,van den Berg CAT,Tijssen RHN

    更新日期:2020-07-01 00:00:00

  • Accelerated MR parameter mapping with low-rank and sparsity constraints.

    abstract:PURPOSE:To enable accurate magnetic resonance (MR) parameter mapping with accelerated data acquisition, utilizing recent advances in constrained imaging with sparse sampling. THEORY AND METHODS:A new constrained reconstruction method based on low-rank and sparsity constraints is proposed to accelerate MR parameter map...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25421

    authors: Zhao B,Lu W,Hitchens TK,Lam F,Ho C,Liang ZP

    更新日期:2015-08-01 00:00:00

  • NMR relaxometric investigation on human methemoglobin and fluoromethemoglobin. An improved quantitative in vitro assay of human methemoglobin.

    abstract::Longitudinal water proton relaxation rates of methemoglobin solutions show a strong dependence on temperature and pH. The increase of the relaxation rates with temperature is associated with shortened exchange lifetime of the coordinated water molecule. An accurate measurement of the relaxation rate of methemoglobin s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330613

    authors: Aime S,Fasano M,Paoletti S,Arnelli A,Ascenzi P

    更新日期:1995-06-01 00:00:00

  • Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

    abstract:PURPOSE:MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to nonlocal effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24848

    authors: Hernando D,Cook RJ,Diamond C,Reeder SB

    更新日期:2013-09-01 00:00:00

  • New double quantum coherence filter for localized detection of glutathione in vivo.

    abstract::In this work, a new double quantum filter for glutathione (GSH) editing is introduced, combined with the point-resolved spectroscopy localization sequence (PRESS), and demonstrated in vivo. Compared to the conventional double quantum coherence filter, the new filter has two major advantages. First, it eliminates the n...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20788

    authors: Zhao T,Heberlein K,Jonas C,Jones DP,Hu X

    更新日期:2006-03-01 00:00:00

  • Assessment of myocardial viability in rats: Evaluation of a new method using superparamagnetic iron oxide nanoparticles and Gd-DOTA at high magnetic field.

    abstract::The aim of this study was to detect salvageable peri-infarction myocardium by MRI in rats after infarction, using with a double contrast agent (CA) protocol at 7 Tesla. Intravascular superparamagnetic iron oxide (SPIO) nanoparticles and an extracellular paramagnetic CA (Gd-DOTA) were used to characterize the peri-infa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20210

    authors: Chapon C,Lemaire L,Franconi F,Marescaux L,Legras P,Denizot B,Le Jeune JJ

    更新日期:2004-10-01 00:00:00

  • The effects of intravoxel contrast agent diffusion on the analysis of DCE-MRI data in realistic tissue domains.

    abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26995

    authors: Woodall RT,Barnes SL,Hormuth DA 2nd,Sorace AG,Quarles CC,Yankeelov TE

    更新日期:2018-07-01 00:00:00

  • A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

    abstract:PURPOSE:This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS:The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28425

    authors: Del Bosque R,Cui J,Ogier S,Cheshkov S,Dimitrov IE,Malloy C,Wright SM,McDougall M

    更新日期:2021-01-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Metabolic markers of neuronal injury correlate with SIV CNS disease severity and inoculum in the macaque model of neuroAIDS.

    abstract::In vivo MR spectroscopy (MRS) studies have shown reductions in NAA/Cr levels in patients with severe neurocognitive deficits due to AIDS dementia complex (ADC), also known as neuroAIDS. The relationship between the cellular changes within the brain during neuroAIDS and the role of NAA/Cr as a metabolic marker remains ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21556

    authors: Lentz MR,Westmoreland SV,Lee V,Ratai EM,Halpern EF,González RG

    更新日期:2008-03-01 00:00:00