Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

Abstract:

PURPOSE:To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY:The proposed technique exploits the inherent phase modulation of SMS imaging with CAIPIRINHA to acquire multiple phase-cycled images, which can be combined for efficient banding reduction within the same scan time of a single-band bSSFP scan. METHODS:Bloch equation simulation, phantom and in vivo brain, abdominal and cardiac imaging experiments were performed on healthy volunteers at 3T using multi-channel head and body array coils with SMS acceleration factors of two to four. The performance of banding reduction was quantitatively evaluated based on the percent ripple of signal distribution and signal-to-noise ratio (SNR) efficiency in both phantom and human studies. RESULTS:The banding artifact was successfully removed or suppressed using phase-cycled SMS bSSFP imaging across SMS factors of two to four. The performance of banding reduction improved with higher SMS factors along with increased SNR efficiency. CONCLUSION:Phase-cycled SMS bSSFP with CAIPIRINHA is a promising technique for efficient band reduction in bSSFP without prolonged scan time. Further evaluation of this technique in clinical applications is warranted. Magn Reson Med 76:1764-1774, 2016. © 2015 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Wang Y,Shao X,Martin T,Moeller S,Yacoub E,Wang DJ

doi

10.1002/mrm.26076

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

1764-1774

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

76

pub_type

杂志文章
  • Direct saturation-corrected chemical exchange saturation transfer MRI of glioma: Simplified decoupling of amide proton transfer and nuclear overhauser effect contrasts.

    abstract:PURPOSE:Chemical exchange saturation transfer (CEST) MRI has shown promise in tissue characterization in diseases like stroke and tumor. However, in vivo CEST imaging such as amide proton transfer (APT) MRI is challenging because of concomitant factors such as direct water saturation, macromolecular magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26959

    authors: Yuwen Zhou I,Wang E,Cheung JS,Lu D,Ji Y,Zhang X,Fulci G,Sun PZ

    更新日期:2017-12-01 00:00:00

  • Water and fat MR imaging with chemical shift selective 3D steady state methods.

    abstract::A new 3D acquisition regimen that enables the collection of conventional, water-suppressed, and fat-suppressed images with no increase in scan times compared with currently implemented 3D sequences is presented. The method is based on conventional 3D steady state with interleaved selective excitation of the fat resona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310403

    authors: Sun L,Aletras AH,Schmalbrock P,Skinner TE,Chakeres D,Irsik R,Robitaille PM

    更新日期:1994-04-01 00:00:00

  • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

    abstract::This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20866

    authors: Herold V,Mörchel P,Faber C,Rommel E,Haase A,Jakob PM

    更新日期:2006-05-01 00:00:00

  • Driving mutually coupled gradient array coils in magnetic resonance imaging.

    abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27768

    authors: Ertan K,Taraghinia S,Atalar E

    更新日期:2019-09-01 00:00:00

  • Feasibility study of imaging a living murine tumor by electron paramagnetic resonance.

    abstract::An electron paramagnetic resonance image was measured for the first time from in vivo field gradient spectra of a living murine tumor (Cloudman S-91 melanoma in the tail of a DBA-2J mouse) using the paramagnetic nitroxide imaging agent 3-carboxamido-2,2,5,5-tetramethylpyrroline-1-oxyl injected into the tail vein. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040410

    authors: Berliner LJ,Fujii H,Wan XM,Lukiewicz SJ

    更新日期:1987-04-01 00:00:00

  • Segmented spin-echo pulses to increase fMRI signal: repeated intrinsic diffusional enhancement.

    abstract::Since its inception, functional magnetic resonance imaging (fMRI) has seen rapid progress in the application to neuroscience. Common gradient-recalled acquisition methods are susceptible to static field inhomogeneities, resulting in signal loss at the medial temporal area important for memory function or at the basal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<631::aid-mrm3>

    authors: Song AW,Mao H,Muthupillai R,Haist F,Dixon WT

    更新日期:1999-10-01 00:00:00

  • Multispectral imaging with three-dimensional rosette trajectories.

    abstract::Two-dimensional intersecting k-space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k-space points leads to destructive interference of the signal coming from the off-resonance spectral peaks; on-resonance data reconstruction yields images of the on-resonance p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21551

    authors: Bucholz EK,Song J,Johnson GA,Hancu I

    更新日期:2008-03-01 00:00:00

  • Automated feature extraction for the classification of human in vivo 13C NMR spectra using statistical pattern recognition and wavelets.

    abstract::If magnetic resonance spectroscopy (MRS) is to become a useful tool in clinical medicine, it will be necessary to find reliable methods for analyzing and classifying MRS data. Automated methods are desirable because they can remove user bias and can deal with large amounts of data, allowing the use of all the availabl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350608

    authors: Tate AR,Watson D,Eglen S,Arvanitis TN,Thomas EL,Bell JD

    更新日期:1996-06-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • Echo-planar imaging of the human fetus in utero.

    abstract::We have demonstrated that echo-planar imaging can be used to produce high-quality snapshot images of the human fetus in utero in a fraction of a second. These images are free of motional artifact or blurring and allow detailed depiction of fetal structures in normal and pathological pregnancies. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130214

    authors: Stehling MK,Mansfield P,Ordidge RJ,Coxon R,Chapman B,Blamire A,Gibbs P,Johnson IR,Symonds EM,Worthington BS

    更新日期:1990-02-01 00:00:00

  • Inversion recovery radial MRI with interleaved projection sets.

    abstract::The radial trajectory has found applications in cardiac imaging because of its resilience to undersampling and motion artifacts. Recent work has shown that interleaved and weighted radial imaging can produce images with multiple contrasts from a single data set. This feature was investigated for inversion recovery ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20865

    authors: Peters DC,Botnar RM,Kissinger KV,Yeon SB,Appelbaum EA,Manning WJ

    更新日期:2006-05-01 00:00:00

  • Atraumatic quantitation of cerebral perfusion in cats by 19F magnetic resonance imaging.

    abstract::We have noninvasively produced low-resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2-ml voxels in eight cats. Typical signal-to-noise of 4 to 1 was obtained in cerebral voxels in 16.5-s epochs. Mean flow during normocapnia (paCO2 = 39 +/- 4 mm Hg) and hypercapnia (paCO2 = 62 +/- 4 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280105

    authors: Branch CA,Ewing JR,Helpern JA,Ordidge RJ,Butt S,Welch KM

    更新日期:1992-11-01 00:00:00

  • Intravoxel incoherent motion imaging using steady-state free precession.

    abstract::IVIM MR imaging is a method which generates images of diffusion and perfusion in vivo. Until now, intravoxel incoherent motion (IVIM) images have been obtained using spin-echo sequences with extragradient pulses, resulting in long acquisition times (typically 2 x 8 min 32 s). A new method is proposed here, using stead...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070312

    authors: Le Bihan D

    更新日期:1988-07-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • A pitfall associated with determination of transverse relaxation times of the 31P NMR signals of ATP using the Hahn spin-echo.

    abstract::T2 measurements of 31P NMR signals of ATP using the Hahn 90 degrees-180 degrees spin-echo sequence imply difficulties whenever the 180 degrees pulse angle is not completely perfect. The reason for this finding is the crucial influence of the J-couplings of the ATP signals which result in intensity modulations and cons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300122

    authors: Jung WI,Straubinger K,Bunse M,Widmaier S,Schick F,Küper K,Dietze G,Lutz O

    更新日期:1993-07-01 00:00:00

  • Assessment of quantitative artificial neural network analysis in a metabolically dynamic ex vivo 31P NMR pig liver study.

    abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380522

    authors: Ala-Korpela M,Changani KK,Hiltunen Y,Bell JD,Fuller BJ,Bryant DJ,Taylor-Robinson SD,Davidson BR

    更新日期:1997-11-01 00:00:00

  • Total liver fat quantification using three-dimensional respiratory self-navigated MRI sequence.

    abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26028

    authors: Arboleda C,Aguirre-Reyes D,García MP,Tejos C,Muñoz L,Miquel JF,Irarrazaval P,Andia ME,Uribe S

    更新日期:2016-11-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • Parallel transmit capability of various RF transmit elements and arrays at 7T MRI.

    abstract:PURPOSE:In this work, 22 configurations for remote radiofrequency (RF) coil arrays consisting of different transmit element designs for 7 Tesla (T) ultrahigh-field MRI are compared by numerical simulations. METHODS:Investigated transmit RF element types are rectangular loops, micro striplines, micro striplines with me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26704

    authors: Rietsch SHG,Orzada S,Bitz AK,Gratz M,Ladd ME,Quick HH

    更新日期:2018-02-01 00:00:00

  • Hormonally induced modulation in the phosphate metabolites of breast cancer: analysis of in vivo 31P MRS signals with a modified prony method.

    abstract::A modified Prony method (MPM) was applied to analyze the main signals present in spatially resolved 31P NMR spectra of MCF7 breast tumors implanted in nude mice. First, the method was tested on synthetic data to establish its limits of reliability. Its performance with respect to peak identification and quantification...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380219

    authors: Viti V,Ragona R,Guidoni L,Barone P,Furman E,Degani H

    更新日期:1997-08-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging for in vivo assessment of damage and functional improvement following spinal cord injury in mice.

    abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20888

    authors: Stieltjes B,Klussmann S,Bock M,Umathum R,Mangalathu J,Letellier E,Rittgen W,Edler L,Krammer PH,Kauczor HU,Martin-Villalba A,Essig M

    更新日期:2006-05-01 00:00:00

  • Articular cartilage deformation determined in an intact tibiofemoral joint by displacement-encoded imaging.

    abstract::This study demonstrates the in vitro displacement and strain of articular cartilage in a cyclically-compressed and intact joint using displacement-encoded imaging with stimulated echoes (DENSE) and fast spin echo (FSE). Deformation and strain fields exhibited complex and heterogeneous patterns. The displacements in th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21927

    authors: Chan DD,Neu CP,Hull ML

    更新日期:2009-04-01 00:00:00

  • Phase contrast MRI with flow compensation view sharing.

    abstract:PURPOSE:To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS:PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25133

    authors: Wang D,Shao J,Rapacchi S,Middione MJ,Ennis DB,Hu P

    更新日期:2015-02-01 00:00:00

  • Gradient, high-resolution, magic-angle spinning nuclear magnetic resonance spectroscopy of human adipocyte tissue.

    abstract::The recently developed technique of gradient, high-resolution magic-angle spinning NMR (g-hr-MAS-NMR) spectroscopy was applied to the study of ex vivo human lipoma and liposarcoma tissue. Compared with conventional 1H-NMR, the g-hr-MAS method yielded a large improvement in spectral resolution and permitted the detecti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380307

    authors: Millis KK,Maas WE,Cory DG,Singer S

    更新日期:1997-09-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • PLANET: An ellipse fitting approach for simultaneous T1 and T2 mapping using phase-cycled balanced steady-state free precession.

    abstract:PURPOSE:To demonstrate the feasibility of a novel, ellipse fitting approach, named PLANET, for simultaneous estimation of relaxation times T1 and T2 from a single 3D phase-cycled balanced steady-state free precession (bSSFP) sequence. METHODS:A method is presented in which the elliptical signal model is used to descri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26717

    authors: Shcherbakova Y,van den Berg CAT,Moonen CTW,Bartels LW

    更新日期:2018-02-01 00:00:00

  • A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.

    abstract::A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10599

    authors: Klarhöfer M,Dilharreguy B,van Gelderen P,Moonen CT

    更新日期:2003-10-01 00:00:00

  • Diffusion-weighted NMR spectroscopy allows probing of 13C labeling of glutamate inside distinct metabolic compartments in the brain.

    abstract::In the present work, diffusion-weighted (DW)-NMR spectroscopy of glutamate was performed during a (13)C-labeled glucose infusion in monkey brain (six experiments). It is shown that glutamate (13)C labeling occurs significantly faster at higher diffusion weightings-slightly for glutamate in position C4, and more marked...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21661

    authors: Valette J,Chaumeil M,Guillermier M,Bloch G,Hantraye P,Lebon V

    更新日期:2008-08-01 00:00:00

  • A continuum of T 2 * components: Flexible fast fraction mapping in sodium MRI.

    abstract:PURPOSE:Parameter mapping in sodium MRI data is challenging due to inherently low SNR and spatial resolution, prompting the need to employ robust models and estimation techniques. This work aims to develop a continuum model of sodium T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27659

    authors: Syeda W,Blunck Y,Kolbe S,Cleary JO,Johnston LA

    更新日期:2019-06-01 00:00:00