Hormonally induced modulation in the phosphate metabolites of breast cancer: analysis of in vivo 31P MRS signals with a modified prony method.

Abstract:

:A modified Prony method (MPM) was applied to analyze the main signals present in spatially resolved 31P NMR spectra of MCF7 breast tumors implanted in nude mice. First, the method was tested on synthetic data to establish its limits of reliability. Its performance with respect to peak identification and quantification of signal intensities was then exploited on data from three implanted tumors during hormonal manipulation with estrogen and the antiestrogenic drug tamoxifen. The phosphomonoester peak was resolved into phosphocholine (PC) and phosphoethanolamine (PE). Treatment with tamoxifen led to a significant reduction in the PE to PE+PC peak amplitude ratio in the tumors under consideration. MPM analysis also revealed the presence of two different inorganic phosphate pools: a larger acidic pool and a smaller alkaline pool during estrogen-induced growth and the reverse during tumor regression.

journal_name

Magn Reson Med

authors

Viti V,Ragona R,Guidoni L,Barone P,Furman E,Degani H

doi

10.1002/mrm.1910380219

subject

Has Abstract

pub_date

1997-08-01 00:00:00

pages

285-95

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

38

pub_type

杂志文章
  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • Relayed nuclear Overhauser enhancement imaging with magnetization transfer contrast suppression at 3 T.

    abstract:PURPOSE:To develop a pulsed CEST magnetization-transfer method for rapidly acquiring relayed nuclear Overhauser enhancement (rNOE)-weighted images with magnetic transfer contrast (MTC) suppression at clinical field strength (3 T). METHODS:Using a pulsed CEST magnetization-transfer method with low saturation powers (B1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28433

    authors: Huang J,Han X,Chen L,Xu X,Xu J,Chan KWY

    更新日期:2021-01-01 00:00:00

  • Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

    abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25785

    authors: Xie Y,Yang Q,Xie G,Pang J,Fan Z,Li D

    更新日期:2016-06-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

    abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22737

    authors: Wang W,Nguyen NM,Yablonskiy DA,Sukstanskii AL,Osmanagic E,Atkinson JJ,Conradi MS,Woods JC

    更新日期:2011-03-01 00:00:00

  • Quantification of fluid changes in rat leg joints with adjuvant arthritis by a one-dimensional magnetic resonance imaging experiment.

    abstract::A simple and reliable method for quantifying the fluid content and characterizing the tissue T2 relaxation properties of animal extremities has been devised. This one-dimensional magnetic resonance imaging experiment, applied to the adjuvant arthritis model in rats, provides a useful, noninvasive monitor of the course...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150208

    authors: Borah B,Szeverenyi NM

    更新日期:1990-08-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

    abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26903

    authors: Bane O,Hectors SJ,Wagner M,Arlinghaus LL,Aryal MP,Cao Y,Chenevert TL,Fennessy F,Huang W,Hylton NM,Kalpathy-Cramer J,Keenan KE,Malyarenko DI,Mulkern RV,Newitt DC,Russek SE,Stupic KF,Tudorica A,Wilmes LJ,Yankeelov TE

    更新日期:2018-05-01 00:00:00

  • Improved MRI R2 * relaxometry of iron-loaded liver with noise correction.

    abstract::Accurate and reproducible MRI R2 * relaxometry for tissue iron quantification is important in managing transfusion-dependent patients. MRI data are often acquired using array coils and reconstructed by the root-sum-square algorithm, and as such, measured signals follow the noncentral chi distribution. In this study, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24607

    authors: Feng Y,He T,Gatehouse PD,Li X,Harith Alam M,Pennell DJ,Chen W,Firmin DN

    更新日期:2013-12-01 00:00:00

  • Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout.

    abstract::Multislice MR images obtained using a fast spin-echo (FSE) readout are strongly affected by magnetization transfer (MT) effects, which will cause a decrease in the observed longitudinal relaxation times for tissues with a large bound water component. This is pertinent for FSE-based inversion-recovery (IR) sequences, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21338

    authors: Meara SJ,Barker GJ

    更新日期:2007-10-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

    abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22234

    authors: Schär M,Vonken EJ,Stuber M

    更新日期:2010-02-01 00:00:00

  • Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

    abstract:PURPOSE:To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY:The proposed technique exploits the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26076

    authors: Wang Y,Shao X,Martin T,Moeller S,Yacoub E,Wang DJ

    更新日期:2016-12-01 00:00:00

  • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts.

    abstract::Leakage of Gd-DTPA through a defective blood-brain barrier is measured quantitatively using dynamic MRI scanning, in which repeated scans are made after a bolus injection. Image registration artifacts are minimized; a dose of 0.1 mM/kg and an IR sequence enable enhancement to be measured quantitatively. The triexponen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170208

    authors: Tofts PS,Kermode AG

    更新日期:1991-02-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • On the origin of paramagnetic inhomogeneity effects in blood.

    abstract::Hydrogen, sodium, and fluorine (added F-) NMR spectra of venous and oxygenated blood were measured. The fluorine resonance was seen as a single peak in both samples, and all three resonances exhibited the same deoxy-oxy shift. Because F- exchanges slowly across the red cell membrane, and because sodium is 95% extracel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120210

    authors: Brooks RA,Brunetti A,Alger JR,Di Chiro G

    更新日期:1989-11-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T.

    abstract::Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the strength of magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22145

    authors: Weigel M,Helms G,Hennig J

    更新日期:2010-01-01 00:00:00

  • RAPID--a new method for fast imaging using a single slice of Z-magnetization.

    abstract::A single slice of z-magnetization is used to generate high-speed images. The slice selection step is achieved using two sin-sinc pulses. This procedure eliminates the need for continual slice gradient reversal, a requirement for the FLASH technique. The RAPID imaging method has less inherent T1 and/or T2 dependence th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050213

    authors: Brooks WM,Brereton IM,Doddrell DM

    更新日期:1987-08-01 00:00:00

  • A strictly noninvasive MR setup dedicated to longitudinal studies of mechanical performance, bioenergetics, anatomy, and muscle recruitment in contracting mouse skeletal muscle.

    abstract::MR techniques have proven their ability to investigate skeletal muscle function in situ. Their benefit in terms of noninvasiveness is, however, lost in animal research, given that muscle stimulation and force output measurements are usually achieved using invasive surgical procedures, thereby excluding repeated invest...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22386

    authors: Giannesini B,Vilmen C,Le Fur Y,Dalmasso C,Cozzone PJ,Bendahan D

    更新日期:2010-07-01 00:00:00

  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Transrectal probe for 1H MRI and 31P MR spectroscopy of the prostate gland.

    abstract::A transrectal probe for 1H imaging and 31P MR spectroscopy of the prostate gland is described. The probe is covered with plastic and consists of an insectional portion containing an rf coil and a handle containing a tuning and matching circuit. Using this transrectal probe, 1H MR images and the first 31P MR spectra of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910110209

    authors: Narayan P,Vigneron DB,Jajodia P,Anderson CM,Hedgcock MW,Tanagho EA,James TL

    更新日期:1989-08-01 00:00:00

  • RACER-GRASP: Respiratory-weighted, aortic contrast enhancement-guided and coil-unstreaking golden-angle radial sparse MRI.

    abstract:PURPOSE:To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27002

    authors: Feng L,Huang C,Shanbhogue K,Sodickson DK,Chandarana H,Otazo R

    更新日期:2018-07-01 00:00:00

  • A one-step biomarker quantification methodology for DCE-MRI of adnexal masses: Capturing kinetic pattern from early to late enhancement.

    abstract:PURPOSE:To develop a one-step quantification approach that accounts for joint preprocessing and quantification of whole-range kinetics (early and late-phase washout) of dynamic contrast-enhanced (DCE) MRI of indeterminate adnexal masses. METHODS:Preoperative DCE-MRI of 43 (24 benign, 19 malignant) sonographically inde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26743

    authors: Fathi Kazerooni A,Nabil M,Haghighat Khah H,Parviz S,Gity M,Saligheh Rad H

    更新日期:2018-02-01 00:00:00

  • On the overestimation of early wall thickening at the carotid bulb by black blood MRI, with implications for coronary and vulnerable plaque imaging.

    abstract::Black blood MRI is an attractive tool for monitoring normal and pathological wall thickening; however, limited spatial resolutions can conspire with complex vascular geometries to distort the appearance of the wall in ways hitherto unclear. To elucidate this, a thin-walled cylinder model was developed to predict the c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21758

    authors: Antiga L,Wasserman BA,Steinman DA

    更新日期:2008-11-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • A hybrid method for more efficient channel-by-channel reconstruction with many channels.

    abstract::In MRI, imaging using receiving coil arrays with a large number of elements is an area of growing interest. With increasing channel numbers for parallel acquisition, longer reconstruction times have become a significant concern. Channel reduction techniques have been proposed to reduce the processing time of channel-b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23048

    authors: Huang F,Lin W,Duensing GR,Reykowski A

    更新日期:2012-03-01 00:00:00

  • MR-guided interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe.

    abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390304

    authors: Tacke J,Adam G,Speetzen R,Brucksch K,Bücker A,Heshel I,Prescher A,van Vaals JJ,Hunter DW,Rau G,Günther RW

    更新日期:1998-03-01 00:00:00

  • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

    abstract::Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20615

    authors: Markl M,Leupold J,Bieri O,Scheffler K,Hennig J

    更新日期:2005-10-01 00:00:00

  • Four-dimensional flow MRI using spiral acquisition.

    abstract::Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23297

    authors: Sigfridsson A,Petersson S,Carlhäll CJ,Ebbers T

    更新日期:2012-10-01 00:00:00