Atraumatic quantitation of cerebral perfusion in cats by 19F magnetic resonance imaging.

Abstract:

:We have noninvasively produced low-resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2-ml voxels in eight cats. Typical signal-to-noise of 4 to 1 was obtained in cerebral voxels in 16.5-s epochs. Mean flow during normocapnia (paCO2 = 39 +/- 4 mm Hg) and hypercapnia (paCO2 = 62 +/- 4 mm Hg) was 53 +/- 20 ml/100 g-min and 140 +/- 36 ml/100 g-min, respectively. Fast flows in normocapnia were 94 +/- 13 and 182 +/- 39 ml/100 g-min in hypercapnia. These results suggest that an atraumatic quantitative imaging assessment of cerebral perfusion may be possible in humans using these techniques.

journal_name

Magn Reson Med

authors

Branch CA,Ewing JR,Helpern JA,Ordidge RJ,Butt S,Welch KM

doi

10.1002/mrm.1910280105

subject

Has Abstract

pub_date

1992-11-01 00:00:00

pages

39-53

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

28

pub_type

杂志文章
  • Understanding and optimizing the amplitude modulated control for multiple-slice continuous arterial spin labeling.

    abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20604

    authors: Utting JF,Thomas DL,Gadian DG,Helliar RW,Lythgoe MF,Ordidge RJ

    更新日期:2005-09-01 00:00:00

  • Fast and accurate calculation of myocardial T1 and T2 values using deep learning Bloch equation simulations (DeepBLESS).

    abstract:PURPOSE:To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1 /T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method. METHODS:Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and ac...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28321

    authors: Shao J,Ghodrati V,Nguyen KL,Hu P

    更新日期:2020-11-01 00:00:00

  • Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling.

    abstract::Perfusion imaging by arterial spin labeling (ASL) can be highly sensitive to the transit time from the labeling site to the tissue. We report the results of a study designed to separate the transit time and perfusion contributions to activation in ASL images accompanying motor and visual stimulation. Fractional transi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<739::aid-mrm17

    authors: Gonzalez-At JB,Alsop DC,Detre JA

    更新日期:2000-05-01 00:00:00

  • Noise correlations in data simultaneously acquired from multiple surface coil arrays.

    abstract::Multiple images acquired simultaneously from an array of surface coils can be combined to give a composite image with an improved signal-to-noise ratio (SNR) and a large field of view. The composite images' SNR can be optimized by taking advantage of noise correlations between coils and phase shifts induced by surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160202

    authors: Hayes CE,Roemer PB

    更新日期:1990-11-01 00:00:00

  • Intravoxel distribution of DWI decay rates reveals C6 glioma invasion in rat brain.

    abstract::The hypothesis was tested that the intravoxel distribution of water diffusion rates, as measured with a stretched-exponential model of diffusion-weighted imaging (DWI), is a marker of brain tumor invasion. Eight rats underwent intracerebral inoculation of C6 glioma cells. In three rats, cells were labeled with a fluor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20286

    authors: Bennett KM,Hyde JS,Rand SD,Bennett R,Krouwer HG,Rebro KJ,Schmainda KM

    更新日期:2004-11-01 00:00:00

  • Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction.

    abstract:PURPOSE:To explore the effects of high permittivity dielectric pads on the transmit and receive characteristics of a 3 Tesla body coil centered at the thighs, and their implications on image uniformity in receive array applications. THEORY AND METHODS:Transmit and receive profiles of the body coil with and without die...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26070

    authors: Brink WM,Versluis MJ,Peeters JM,Börnert P,Webb AG

    更新日期:2016-12-01 00:00:00

  • Improved myo-inositol detection through Carr-Purcell PRESS: a tool for more sensitive mild cognitive impairment diagnosis.

    abstract::A 3-T study is presented, comparing the ability of two (1) H spectroscopy pulse sequences, Carr-Purcell point resolved spectroscopy (CPRESS; TE = 45 msec), and conventional PRESS (TE = 35 msec), to separate between groups of 20 normal control (NC) and 20 mild cognitive impairment (MCI) subjects. Both sequences showed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22749

    authors: Hancu I,Gillen R,Cowan J,Zimmerman EA

    更新日期:2011-06-01 00:00:00

  • A 13C NMR study of the application of [U-13C]succinate for metabolic investigations in rabbit renal proximal convoluted tubular cells.

    abstract::The fate of the 13C label arising from [U-13C]succinate in rabbit renal proximal convoluted tubular (PCT) cells, incubated with [U-13C]succinate, was investigated by 13C NMR spectroscopy of the perchloric acid extracts of the cell pellets. The 13C label of [U-13C]succinate was predominantly metabolized into glutamate,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140114

    authors: Jans AW,Willem R

    更新日期:1990-04-01 00:00:00

  • Modification of embolic-PVA particles with MR contrast agents.

    abstract::We report the synthesis and characterization of polyvinyl alcohol (PVA) embolic particles modified with a clinically approved magnetic resonance (MR) contrast agent. PVA particles are used during transcatheter arterial embolization (TAE) procedures and this minimally invasive technique is a widely employed treatment f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21518

    authors: Cilliers R,Song Y,Kohlmeir EK,Larson AC,Omary RA,Meade TJ

    更新日期:2008-04-01 00:00:00

  • Calcium-induced structural changes of cartilage proteoglycans studied by H NMR relaxometry and diffusion measurements.

    abstract::1H transverse nuclear magnetic relaxation times (T2) and self-diffusion coefficients (SDCs) of water were measured in isolated proteoglycan aggregates from pig articular cartilage. The influence of varying osmotic pressure, as well as of different calcium concentrations, on the samples was investigated. Due to a struc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<43::aid-mrm8>3

    authors: Werner A,Gründer W

    更新日期:1999-01-01 00:00:00

  • Contributions of chemical exchange to T1ρ dispersion in a tissue model.

    abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22947

    authors: Cobb JG,Xie J,Gore JC

    更新日期:2011-12-01 00:00:00

  • Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

    abstract:PURPOSE:MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to nonlocal effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24848

    authors: Hernando D,Cook RJ,Diamond C,Reeder SB

    更新日期:2013-09-01 00:00:00

  • On the calculation of magnetization slice profiles for NMR imaging and in vivo spectroscopy.

    abstract::When developing new techniques for NMR imaging and in vivo spectroscopy it is a major advantage to be able to calculate the magnetization slice profiles, at any point during a pulse sequence in the presence of a field gradient. While this has frequently been done by treating the problem as a number of discrete resonan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050511

    authors: Bulsing JM,Galloway GJ,Brereton IM,Doddrell DM

    更新日期:1987-11-01 00:00:00

  • New "multicolor" polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI.

    abstract::An array of 33 prototype polypeptides was examined as putative contrast agents that can be distinguished from each other based on the chemical exchange saturation transfer (CEST) mechanism. These peptides were chosen based on predictions of the chemical exchange rates of exchangeable amide, amine, and hydroxyl protons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21683

    authors: McMahon MT,Gilad AA,DeLiso MA,Berman SM,Bulte JW,van Zijl PC

    更新日期:2008-10-01 00:00:00

  • Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

    abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10133

    authors: Subramanian S,Yamada K,Irie A,Murugesan R,Cook JA,Devasahayam N,Van Dam GM,Mitchell JB,Krishna MC

    更新日期:2002-05-01 00:00:00

  • Feasibility of multiple-mouse dynamic contrast-enhanced MRI.

    abstract::Dynamic contrast-enhanced (DCE-) MRI is often used to evaluate the response to experimental antiangiogenic therapies in small animal models of cancer. Unfortunately, DCE-MRI studies often require a substantial investment of both time and money to achieve the desired level of statistical significance. Multiple-mouse MR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21348

    authors: Ramirez MS,Ragan DK,Kundra V,Bankson JA

    更新日期:2007-09-01 00:00:00

  • Chemical shift-induced phase errors in phase-contrast MRI.

    abstract::Phase-contrast magnetic resonance imaging is subject to numerous sources of error, which decrease clinical confidence in the reported measures. This work outlines how stationary perivascular fat can impart a significant chemical shift induced phase-contrast magnetic resonance imaging measurement error using computatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24262

    authors: Middione MJ,Ennis DB

    更新日期:2013-02-01 00:00:00

  • Porous medium 3D flow simulation of contrast media washout in cardiac MRI reflects myocardial injury.

    abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27756

    authors: Riazy L,Schaeffter T,Olbrich M,Schueler J,von Knobelsdorff-Brenkenhoff F,Niendorf T,Schulz-Menger J

    更新日期:2019-08-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver.

    abstract:PURPOSE:To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28452

    authors: Zhao R,Hamilton G,Brittain JH,Reeder SB,Hernando D

    更新日期:2021-02-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

    abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26903

    authors: Bane O,Hectors SJ,Wagner M,Arlinghaus LL,Aryal MP,Cao Y,Chenevert TL,Fennessy F,Huang W,Hylton NM,Kalpathy-Cramer J,Keenan KE,Malyarenko DI,Mulkern RV,Newitt DC,Russek SE,Stupic KF,Tudorica A,Wilmes LJ,Yankeelov TE

    更新日期:2018-05-01 00:00:00

  • Measurements of T(1) -relaxation in ex vivo prostate tissue at 132 μT.

    abstract::The proton T(1) was measured at 132 μT in ex vivo prostate tissue specimens from radical prostatectomies of 35 patients with prostate cancer. Each patient provided two specimens. The NMR and MRI measurements involved proton repolarization, a field of typically 150 mT and detection of the 5.6-kHz signal with a supercon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24177

    authors: Busch S,Hatridge M,Mößle M,Myers W,Wong T,Mück M,Chew K,Kuchinsky K,Simko J,Clarke J

    更新日期:2012-04-01 00:00:00

  • Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.

    abstract:PURPOSE:This study aims to identify work-related and personal factors associated with workers' exposure to static magnetic fields (SMF) and motion-induced time-varying magnetic fields (TVMF) from MRI scanners. METHODS:Measurements of personal exposure to SMF and TVMF were performed among MRI staff during 439 work shif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25720

    authors: Schaap K,Christopher-De Vries Y,Cambron-Goulet É,Kromhout H

    更新日期:2016-05-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

    abstract::Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21676

    authors: Helms G,Finsterbusch J,Weiskopf N,Dechent P

    更新日期:2008-09-01 00:00:00

  • Analysis of the evolution of focal cerebral ischemia in the rat using the eigenimage filter.

    abstract::The eigenimage filter was used to evaluate the results of a MRI study of cerebral ischemia in a rat model. This linear filter segments a desired feature in an image sequence from other features which may interfere with its observation. The animals were imaged temporally, after occlusion of the middle cerebral artery, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260207

    authors: Peck DJ,Spickler EM,Knight RA,Hearshen DO,Windham JP

    更新日期:1992-08-01 00:00:00

  • Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

    abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24824

    authors: Lee SK,Tan ET,Govenkar A,Hancu I

    更新日期:2014-05-01 00:00:00