Improved myo-inositol detection through Carr-Purcell PRESS: a tool for more sensitive mild cognitive impairment diagnosis.

Abstract:

:A 3-T study is presented, comparing the ability of two (1) H spectroscopy pulse sequences, Carr-Purcell point resolved spectroscopy (CPRESS; TE = 45 msec), and conventional PRESS (TE = 35 msec), to separate between groups of 20 normal control (NC) and 20 mild cognitive impairment (MCI) subjects. Both sequences showed higher myo-inositol (mI) and mI/N-acetyl-aspartate (NAA) levels in the posterior cingulate gyrus of the MCI subjects. The increased intrasubject repeatability of mI and mI/NAA CPRESS measurements (∼ 6% vs. 9% for PRESS) translated into decreased intraclass variability. A 22% intraclass mI PRESS variability was reduced to 16% for CPRESS, and an 18% intraclass mI/NAA PRESS variability was reduced to 12% for CPRESS for the group of NC subjects. Similar results were observed for the MCI subjects. Decreased intraclass variability led to improved separation between NC and MCI subjects (P = 0.017 for PRESS and P < 0.0001 for CPRESS mI/NAA, the best NC/MCI discriminant for each method). Seventy-five percent sensitivity at eighty percent specificity was demonstrated by mI/NAA CPRESS measurements in separating NC from MCI subjects. High correlations were also observed between subject performance on a number of neuropsychological tests (probing verbal memory, visuoconstruction performance, and visual motor integration) and the mI/NAA ratio; higher correlation coefficients (with stronger statistical significance) were consistently evident for CPRESS than for PRESS data.

journal_name

Magn Reson Med

authors

Hancu I,Gillen R,Cowan J,Zimmerman EA

doi

10.1002/mrm.22749

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

1515-21

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

65

pub_type

杂志文章
  • Understanding and optimizing the amplitude modulated control for multiple-slice continuous arterial spin labeling.

    abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20604

    authors: Utting JF,Thomas DL,Gadian DG,Helliar RW,Lythgoe MF,Ordidge RJ

    更新日期:2005-09-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Pulmonary edema induced by allergen challenge in the rat: noninvasive assessment by magnetic resonance imaging.

    abstract::The course of pulmonary edema formation after an intratracheal (i.t.) instillation of ovalbumin was followed noninvasively by magnetic resonance imaging (MRI) in actively sensitized Brown Norway (BN) rats. Changes in edema volume assessed by MRI mimicked the results from the analysis of the number and activation of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<88::aid-mrm1013>3.0.

    authors: Beckmann N,Tigani B,Ekatodramis D,Borer R,Mazzoni L,Fozard JR

    更新日期:2001-01-01 00:00:00

  • Automated feature extraction for the classification of human in vivo 13C NMR spectra using statistical pattern recognition and wavelets.

    abstract::If magnetic resonance spectroscopy (MRS) is to become a useful tool in clinical medicine, it will be necessary to find reliable methods for analyzing and classifying MRS data. Automated methods are desirable because they can remove user bias and can deal with large amounts of data, allowing the use of all the availabl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350608

    authors: Tate AR,Watson D,Eglen S,Arvanitis TN,Thomas EL,Bell JD

    更新日期:1996-06-01 00:00:00

  • Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI.

    abstract:PURPOSE:To develop an MRI acquisition and reconstruction framework for volumetric cine visualization of the fetal heart and great vessels in the presence of maternal and fetal motion. METHODS:Four-dimensional (4D) depiction was achieved using a highly-accelerated multi-planar real-time balanced steady-state free prece...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27798

    authors: van Amerom JFP,Lloyd DFA,Deprez M,Price AN,Malik SJ,Pushparajah K,van Poppel MPM,Rutherford MA,Razavi R,Hajnal JV

    更新日期:2019-09-01 00:00:00

  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • Multiclass imbalance learning: Improving classification of pediatric brain tumors from magnetic resonance spectroscopy.

    abstract:PURPOSE:Classification of pediatric brain tumors from 1 H-magnetic resonance spectroscopy (MRS) can aid diagnosis and management of brain tumors. However, varied incidence of the different tumor types leads to imbalanced class sizes and introduces difficulties in classifying rare tumor groups. This study assessed diffe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26318

    authors: Zarinabad N,Wilson M,Gill SK,Manias KA,Davies NP,Peet AC

    更新日期:2017-06-01 00:00:00

  • Probing treatment response of glutaminolytic prostate cancer cells to natural drugs with hyperpolarized [5-(13) C]glutamine.

    abstract:PURPOSE:The correlation between glutamine metabolism and oncogene expression in cancers has led to a renewed interest in the role of glutamine in cancer cell survival. Hyperpolarized [5-(13) C]glutamine is evaluated as a potential biomarker for noninvasive metabolic measurements of drug response in prostate cancer cell...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25360

    authors: Canapè C,Catanzaro G,Terreno E,Karlsson M,Lerche MH,Jensen PR

    更新日期:2015-06-01 00:00:00

  • B factor dependence of the temporal characteristics of brain activation using dynamic apparent diffusion coefficient contrast.

    abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20293

    authors: Harshbarger TB,Song AW

    更新日期:2004-12-01 00:00:00

  • Dynamic glucose-enhanced (DGE) MRI in the human brain at 7 T with reduced motion-induced artifacts based on quantitative R1ρ mapping.

    abstract:PURPOSE:Dynamic glucose-enhanced (DGE)-MRI based on chemical exchange-sensitive MRI, that is, glucoCEST and gluco-chemical exchange-sensitive spin-lock (glucoCESL), is intrinsically prone to motion-induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28112

    authors: Boyd PS,Breitling J,Zimmermann F,Korzowski A,Zaiss M,Schuenke P,Weinfurtner N,Schlemmer HP,Ladd ME,Bachert P,Paech D,Goerke S

    更新日期:2020-07-01 00:00:00

  • Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

    abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24137

    authors: Song T,Stainsby JA,Ho VB,Hood MN,Slavin GS

    更新日期:2012-03-01 00:00:00

  • Spectral baseline correction using CLEAN.

    abstract::Baseline distortion in NMR spectroscopy, caused by the "dead time" between signal excitation and detection, makes quantitative interpretation difficult and is aesthetically displeasing. Here the use of the CLEAN algorithm for deconvolving the effect of signal dead time to produce a distortionless baseline is discussed...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130113

    authors: McKinnon GC,Burger C,Boesiger P

    更新日期:1990-01-01 00:00:00

  • Trajectory optimization based on the signal-to-noise ratio for spatial encoding with nonlinear encoding fields.

    abstract:PURPOSE:Multiple nonlinear gradient fields offer many potential benefits for spatial encoding including reduced acquisition time, fewer artefacts and region-specific imaging, although designing a suitable trajectory for such a setup is difficult. This work aims to optimize encoding trajectories for multiple nonlinear g...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25859

    authors: Layton KJ,Kroboth S,Jia F,Littin S,Yu H,Zaitsev M

    更新日期:2016-07-01 00:00:00

  • A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T.

    abstract::Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dep...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22962

    authors: Deppe MH,Parra-Robles J,Marshall H,Lanz T,Wild JM

    更新日期:2011-12-01 00:00:00

  • Quantification of the pulse wave velocity of the descending aorta using axial velocity profiles from phase-contrast magnetic resonance imaging.

    abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21034

    authors: Yu HY,Peng HH,Wang JL,Wen CY,Tseng WY

    更新日期:2006-10-01 00:00:00

  • Interindividual reproducibility of glutamate quantification using 1.5-T proton magnetic resonance spectroscopy.

    abstract::The goal of this study was to measure the interindividual reproducibility of glutamate quantification in 1.5-T (1)H MRS of human brains. To determine the effective echo time (TE) for glutamate quantification, spectra from a phantom and 12 participants were obtained with TE = 30, 35, 40, and 144 ms (repetition time (TR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20387

    authors: Jang DP,Lee JM,Lee E,Park S,Kim JJ,Namkoong K,Yoon KJ,Kim IY,Kim SI

    更新日期:2005-03-01 00:00:00

  • Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic imaging of water and fat resonances.

    abstract::Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist gh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10485

    authors: Du W,Du YP,Fan X,Zamora MA,Karczmar GS

    更新日期:2003-06-01 00:00:00

  • Editing through multiple bonds: threonine detection.

    abstract::In in vivo (1)H spectroscopy, the signal at 1.32 ppm is usually assigned to lactate. This resonance position is shared with threonine at physiological pH. The similarity of spectral patterns of lactate and threonine renders the separate measurement of either threonine or lactate without and even with editing technical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21492

    authors: Marjanska M,Henry PG,Uğurbil K,Gruetter R

    更新日期:2008-02-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition.

    abstract::Spatial resolution in 3D breath-hold coronary MR angiography (MRA) is limited by imaging time. The purpose of this work was to investigate the feasibility of improving the spatial resolution of coronary MRA using generalized autocalibrating partially parallel acquisition (GRAPPA) and fast imaging with steady state pre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20153

    authors: Park J,McCarthy R,Li D

    更新日期:2004-07-01 00:00:00

  • Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25101

    authors: Powell NJ,Jang A,Park JY,Valette J,Garwood M,Marjańska M

    更新日期:2015-01-01 00:00:00

  • Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

    abstract::Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k-space trajectories (ra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23018

    authors: Snyder J,Haas M,Hennig J,Zaitsev M

    更新日期:2012-02-01 00:00:00

  • A torque balance measurement of anisotropy of the magnetic susceptibility in white matter.

    abstract:PURPOSE:Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25524

    authors: van Gelderen P,Mandelkow H,de Zwart JA,Duyn JH

    更新日期:2015-11-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • Direction-averaged diffusion-weighted MRI signal using different axisymmetric B-tensor encoding schemes.

    abstract:PURPOSE:It has been shown, theoretically and in vivo, that using the Stejskal-Tanner pulsed-gradient, or linear tensor encoding (LTE), and in tissue exhibiting a "stick-like" diffusion geometry, the direction-averaged diffusion-weighted MRI signal at high b-values ( ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28191

    authors: Afzali M,Aja-Fernández S,Jones DK

    更新日期:2020-09-01 00:00:00

  • ΔR2 (*) gadolinium-diethylenetriaminepentacetic acid relaxivity in venous blood.

    abstract::The accuracy of perfusion measurements using dynamic, susceptibility-weighted, contrast-enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both bloo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24331

    authors: Patil V,Johnson G

    更新日期:2013-04-01 00:00:00