Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition.

Abstract:

:Spatial resolution in 3D breath-hold coronary MR angiography (MRA) is limited by imaging time. The purpose of this work was to investigate the feasibility of improving the spatial resolution of coronary MRA using generalized autocalibrating partially parallel acquisition (GRAPPA) and fast imaging with steady state precession (True-FISP) data acquisition. Coronary data were acquired in 10 healthy volunteers. In five volunteers, the data were fully acquired in k-space and decimated for GRAPPA with an outer reduction factor (ORF) of 2. The coil calibration in GRAPPA was improved by segmented least-squares fitting along the frequency-encoding direction. More than 5% of the total k-space lines were required for the calibration to achieve acceptable artifact suppression despite slightly lower signal-to-noise ratio (SNR). In another five volunteers, coronary data were obtained with both conventional and accelerated data acquisitions in the same imaging time. GRAPPA allowed a submillimeter in-plane resolution, and improved coronary artery definition with an acceptable loss of SNR. In conclusion, 3D breath-hold coronary MRA by GRAPPA and True-FISP is highly feasible.

journal_name

Magn Reson Med

authors

Park J,McCarthy R,Li D

doi

10.1002/mrm.20153

subject

Has Abstract

pub_date

2004-07-01 00:00:00

pages

7-13

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

52

pub_type

杂志文章
  • Spin-echo MRI using pi/2 and pi hyperbolic secant pulses.

    abstract::Frequency-modulated (FM) pulses have practical advantages for spin-echo experiments, such as the ability to produce a broadband pi rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21822

    authors: Park JY,Garwood M

    更新日期:2009-01-01 00:00:00

  • NOE enhancements and T1 relaxation times of phosphorylated metabolites in human calf muscle at 1.5 Tesla.

    abstract::Nuclear Overhauser effect (NOE) enhancements and relaxation times of 31P metabolites in human calf were measured in 12 volunteers (4 men and 8 women) at 1.5 T using a dual tuned four-ring birdcage. The NOE enhancements of inorganic phosphate (Pi), phosphocreatine (PCr), gamma-, alpha-, and beta-nucleoside triphosphate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330316

    authors: Brown TR,Stoyanova R,Greenberg T,Srinivasan R,Murphy-Boesch J

    更新日期:1995-03-01 00:00:00

  • Stream function optimization for gradient coil design.

    abstract::This work presents a method applied to the design of short self-shielded gradient coils of cylindrical geometry. The method uses a hybrid technique that combines the simulated annealing and target field methods to optimize the standard stream functions. The optimized stream functions were parameterized using a few deg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<505::aid-mrm1066>3.0

    authors: Tomasi D

    更新日期:2001-03-01 00:00:00

  • Novel quadrature birdcage coil for a vertical B(0) field open MRI system.

    abstract::A birdcage coil possesses various intrinsic resonant modes. One of the modes produces sinusoidal current distribution around the rung elements of the birdcage and generates a highly uniform B(1) field in the transverse plane. Another mode is the end-ring resonant mode, in which there are no currents in the rungs of th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<633::aid-mrm18>3.0.c

    authors: Fujita H,Braum WO,Morich MA

    更新日期:2000-10-01 00:00:00

  • Differential effect of isoflurane, medetomidine, and urethane on BOLD responses to acute levo-tetrahydropalmatine in the rat.

    abstract::Levo-tetrahydropalmatine (l-THP) has shown significant promise in preclinical and clinical studies to treat drug addiction. Pharmacological MRI methods can elucidate the regional cerebral effects of l-THP, but there are potential confounds from the use of general anesthesia. To investigate the possible anesthetic-drug...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23243

    authors: Liu X,Li R,Yang Z,Hudetz AG,Li SJ

    更新日期:2012-08-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Off-resonance effects in the transient response of SSFP sequences.

    abstract::A previously developed eigenvector formalism is adapted to off-resonance in the transient response of quasiperiodic steady-state free precession (SSFP) sequences, including TrueFISP as a special case. The effective relaxation rates for essentially parallel and perpendicular deviations from the steady state are determi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20173

    authors: Ganter C

    更新日期:2004-08-01 00:00:00

  • Cellular imaging and texture analysis distinguish differences in cellular dynamics in mouse brain tumors.

    abstract:PURPOSE:The heterogeneous tumor cell population and dynamic microenvironment within a tumor lead to regional variations in cell proliferation, migration, and differentiation. In this work, MRI and optical projection tomography were used to examine and compare the redistribution of a cellular label in two mouse glioma m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24790

    authors: Gazdzinski LM,Nieman BJ

    更新日期:2014-04-01 00:00:00

  • In vivo field-cycling relaxometry using an insert coil for magnetic field offset.

    abstract:PURPOSE:The T(1) of tissue has a strong dependence on the measurement magnetic field strength. T(1) -dispersion could be a useful contrast parameter, but is unavailable to clinical MR systems which operate at fixed magnetic field strength. The purpose of this work was to implement a removable insert magnet coil for fie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25040

    authors: Pine KJ,Goldie F,Lurie DJ

    更新日期:2014-11-01 00:00:00

  • Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

    abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21157

    authors: Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

    更新日期:2007-03-01 00:00:00

  • Detection of neural activity in functional MRI using canonical correlation analysis.

    abstract::A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0

    authors: Friman O,Cedefamn J,Lundberg P,Borga M,Knutsson H

    更新日期:2001-02-01 00:00:00

  • Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26559

    authors: Wang Y,Zhang Y,Zhao X,Wu B,Gao JH

    更新日期:2017-11-01 00:00:00

  • Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize, and quantify the strain rates of the active human myocardium.

    abstract::A magnetic resonance imaging (MRI) method is presented to detect, localize, and quantify myocardial kinematics by measuring the material rate-of-strain tensor at each pixel in gated NMR images of the heart. The immediate, local effect of muscular activity is self-deformation, and the strain tensor is the basic mathema...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270107

    authors: Wedeen VJ

    更新日期:1992-09-01 00:00:00

  • Joint image reconstruction and sensitivity estimation in SENSE (JSENSE).

    abstract::Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21245

    authors: Ying L,Sheng J

    更新日期:2007-06-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • 3D compressed sensing for highly accelerated hyperpolarized (13)C MRSI with in vivo applications to transgenic mouse models of cancer.

    abstract::High polarization of nuclear spins in liquid state through hyperpolarized technology utilizing dynamic nuclear polarization has enabled the direct monitoring of (13)C metabolites in vivo at a high signal-to-noise ratio. Acquisition time limitations due to T(1) decay of the hyperpolarized signal require accelerated ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22233

    authors: Hu S,Lustig M,Balakrishnan A,Larson PE,Bok R,Kurhanewicz J,Nelson SJ,Goga A,Pauly JM,Vigneron DB

    更新日期:2010-02-01 00:00:00

  • Projection reconstruction MR imaging using FOCUSS.

    abstract::The focal underdetermined system solver (FOCUSS) was originally designed to obtain sparse solutions by successively solving quadratic optimization problems. This article adapts FOCUSS for a projection reconstruction MR imaging problem to obtain high resolution reconstructions from angular under-sampled radial k-space ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21202

    authors: Ye JC,Tak S,Han Y,Park HW

    更新日期:2007-04-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • Fat-water separation based on Transition REgion Extraction (TREE).

    abstract:PURPOSE:To develop a method based on fat-water transition region extraction (TREE) for robust fat-water separation and quantification in challenging scenarios, including low signal-to-noise ratio (SNR), fast changing B0 field, and disjointed anatomies. THEORY AND METHODS:In TREE method, the phasor solutions of each pi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27710

    authors: Peng H,Zou C,Cheng C,Tie C,Qiao Y,Wan Q,Lv J,He Q,Liang D,Liu X,Liu W,Zheng H

    更新日期:2019-07-01 00:00:00

  • MRI assessment of coronary microvascular endothelial nitric oxide synthase function using myocardial T1 mapping.

    abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26870

    authors: Cui SX,Epstein FH

    更新日期:2018-04-01 00:00:00

  • Water-suppressed one-dimensional 1H NMR spectroscopic imaging of myocardial metabolites in vivo.

    abstract::Excitation by conventional B1 pulses in surface coil chemical-shift imaging experiments yields resonance intensities that vary greatly with position. B1-compensated semi-selective pulses overcome much of this problem. These pulses are employed for excitation and refocusing in 1H NMR spectroscopic localization in the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250118

    authors: Balschi JA,Hetherington HP,Pohost GM

    更新日期:1992-05-01 00:00:00

  • Recovery of the rodent brain after cardiac arrest: a functional MRI study.

    abstract::Recovery of the cerebral cortex after 10 min of cardiac arrest was studied in rat using noninvasive MRI techniques. The apparent diffusion coefficient (ADC) of brain water was imaged to document reversal of the metabolic impairment. Perfusion-weighted imaging and blood oxygen level dependent (BOLD) imaging were perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390516

    authors: Schmitz B,Bock C,Hoehn-Berlage M,Kerskens CM,Böttiger BW,Hossmann KA

    更新日期:1998-05-01 00:00:00

  • Iterative correction of RF envelope distortion with GRATER-measured waveforms.

    abstract:PURPOSE:To develop and evaluate a method for RF envelope correction without extra hardware or synchronization. METHODS:Transmitted RF waveforms are measured through a simple pulse sequence called the gradient reversal approach to evaluate RF (GRATER). The measured RF waveforms are used to compute predistorted RF wavef...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27930

    authors: Landes VL,Nayak KS

    更新日期:2020-01-01 00:00:00

  • On multiple alternating steady states induced by periodic spin phase perturbation waveforms.

    abstract::Direct measurement of neural currents by means of MRI can potentially open a high temporal resolution (10-100 ms) window applicable for monitoring dynamics of neuronal activity without loss of the high spatial resolution afforded by MRI. Previously, we have shown that the alternating balanced steady state imaging affo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23105

    authors: Buračas GT,Jung Y,Lee J,Buxton RB,Wong EC,Liu TT

    更新日期:2012-05-01 00:00:00

  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Quantitative fat and R2* mapping in vivo to measure lipid-rich necrotic core and intraplaque hemorrhage in carotid atherosclerosis.

    abstract:PURPOSE:The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS:Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were gen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26359

    authors: Koppal S,Warntjes M,Swann J,Dyverfeldt P,Kihlberg J,Moreno R,Magee D,Roberts N,Zachrisson H,Forssell C,Länne T,Treanor D,de Muinck ED

    更新日期:2017-07-01 00:00:00

  • Acceleration and motion-correction techniques for high-resolution intravascular MRI.

    abstract:PURPOSE:High-resolution intravascular (IV) MRI is susceptible to degradation from physiological motion and requires high frame-rates for true endoscopy. Traditional cardiac-gating techniques compromise efficiency by reducing the effective scan rate. Here we test whether compressed sensing (CS) reconstruction and ungate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25436

    authors: Hegde SS,Zhang Y,Bottomley PA

    更新日期:2015-08-01 00:00:00

  • Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.

    abstract::The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23269

    authors: Grissom WA,McKinnon GC,Vogel MW

    更新日期:2012-09-01 00:00:00

  • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

    abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

    authors: Basser PJ,Pajevic S

    更新日期:2000-07-01 00:00:00