Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

Abstract:

:This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a homogeneous region of interest (ROI), here it is shown that magnitude sorting also introduces a significant bias in the variance of the sample mean eigenvalues. New methods are presented to calculate the mean and variance of the eigenvectors of the diffusion tensor, based on a dyadic tensor representation of eigenvalue-eigenvector pairs. Based on their use it is shown that sorting eigenvalues by magnitude also introduces a bias in the mean and the variance of the sample eigenvectors (principal directions). This required the development of new methods to calculate the mean and variance of the eigenvectors of the diffusion tensor, based on a dyadic tensor representation of eigenvalue-eigenvector pairs. Moreover, a new approach is proposed to order these pairs within an ROI. To do this, a correspondence between each principal axis of the diffusion ellipsoid, an eigenvalue-eigenvector pair, and a dyadic tensor constructed from it is exploited. A measure of overlap between principal axes of diffusion ellipsoids in different voxels is defined that employs projections between these dyadic tensors. The optimal eigenvalue assignment within an ROI maximizes this overlap. Bias in the estimate of the mean and of the variance of the eigenvalues and of their corresponding eigenvectors is reduced in DT-MRI experiments and in Monte Carlo simulations of such experiments. Improvement is most significant in isotropic regions, but some is also observed in anisotropic regions. This statistical framework should enhance our ability to characterize microstructure and architecture of healthy tissue, and help to assess its changes in development, disease, and degeneration. Mitigating these artifacts should also improve the characterization of diffusion anisotropy and the elucidation of fiber-tract trajectories in the brain and in other fibrous tissues. Magn Reson Med 44:41-50, 2000. Published 2000 Wiley-Liss, Inc.

journal_name

Magn Reson Med

authors

Basser PJ,Pajevic S

doi

10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

subject

Has Abstract

pub_date

2000-07-01 00:00:00

pages

41-50

issue

1

eissn

0740-3194

issn

1522-2594

pii

10.1002/1522-2594(200007)44:1<41::AID-MRM8>3.0.CO;

journal_volume

44

pub_type

杂志文章
  • Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

    abstract::Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22725

    authors: Yang C,Deng W,Stenger VA

    更新日期:2011-02-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

    abstract:PURPOSE:We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion-weighted imaging (DWI). METHODS:First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction alg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25318

    authors: Chang HC,Guhaniyogi S,Chen NK

    更新日期:2015-05-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • 31P NMR spectroscopy of 9L cell line in culture: differential effects of high temperature on anchored cells and spheroids.

    abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190233

    authors: Suzuki N,Kwee IL,Tamas LB,Nakada T

    更新日期:1991-06-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • DeepCEST: 9.4 T Chemical exchange saturation transfer MRI contrast predicted from 3 T data - a proof of concept study.

    abstract:PURPOSE:To determine the feasibility of employing the prior knowledge of well-separated chemical exchange saturation transfer (CEST) signals in the 9.4 T Z-spectrum to separate overlapping CEST signals acquired at 3 T, using a deep learning approach trained with 3 T and 9.4 T CEST spectral data from brains of the same ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27690

    authors: Zaiss M,Deshmane A,Schuppert M,Herz K,Glang F,Ehses P,Lindig T,Bender B,Ernemann U,Scheffler K

    更新日期:2019-06-01 00:00:00

  • Uncovering of intracellular water in cultured cells.

    abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20565

    authors: Galons JP,Lope-Piedrafita S,Divijak JL,Corum C,Gillies RJ,Trouard TP

    更新日期:2005-07-01 00:00:00

  • Visualization of cortical spreading depression using manganese-enhanced magnetic resonance imaging.

    abstract::Cortical spreading depression (CSD) was visualized using manganese-enhanced MRI (MEMRI) following topical application of KCl to the exposed rat cortex. MEMRI signal increase in the ipsilateral cortex relative to the contralateral control region was 60 +/- 30% following two KCl applications. MEMRI signal increase for a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20438

    authors: Henning EC,Meng X,Fisher M,Sotak CH

    更新日期:2005-04-01 00:00:00

  • Interventional MR elastography for MRI-guided percutaneous procedures.

    abstract:PURPOSE:MRI-guided thermal ablations require reliable monitoring methods to ensure complete destruction of the diseased tissue while avoiding damage to the surrounding healthy tissue. Based on the fact that thermal ablations result in substantial changes in biomechanical properties, interventional MR elastography (MRE)...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25694

    authors: Corbin N,Vappou J,Breton E,Boehler Q,Barbé L,Renaud P,de Mathelin M

    更新日期:2016-03-01 00:00:00

  • Analysis of phospholipid molecular species in brain by (31)P NMR spectroscopy.

    abstract::Techniques are described for the (31)P NMR analysis of glycerophospholipid (PL) headgroup and molecular species in brain. The (31)P NMR spectrum of PLs from human temporal cortex, solubilized in aqueous Na cholate, typically showed 3 major resonances, assigned to phosphatidylcholine (PC) molecular species containing 0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200008)44:2<215::aid-mrm8>3.0.co

    authors: Pearce JM,Komoroski RA

    更新日期:2000-08-01 00:00:00

  • The effect of B1 field inhomogeneity and the nonselective inversion profile on the kinetics of FAIR-based perfusion MRI.

    abstract::Perfusion imaging with pulsed arterial spin labeling techniques, like flow-sensitive alternating inversion recovery (FAIR), may suffer from inflow of fresh, i.e., unlabeled, spins. Inflow of fresh spins is caused by the arrival of unlabeled spins in the image slice and can lead to underestimation of the perfusion if n...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20480

    authors: Schepers J,van Osch MJ,Bartels LW,Heukels SN,Viergever MA,Nicolay K

    更新日期:2005-06-01 00:00:00

  • Improved estimation of velocity and flow rate using regularized three-point phase-contrast velocimetry.

    abstract::We improved the three-point phase-contrast method by regularization of MR velocity data after acquisition of a low velocity-to-noise ratio (VNR) velocity image and a high VNR aliased velocity image. The phase unwrapping algorithm is based on the assumed correlation of the velocity of adjacent flow voxels on the low VN...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<122::aid-mrm18>3.0.c

    authors: Herment A,Mousseaux E,Jolivet O,DeCesare A,Frouin F,Todd-Pokropek A,Bittoun J

    更新日期:2000-07-01 00:00:00

  • Skeletal muscle ¹H MRSI before and after prolonged exercise. I. muscle specific depletion of intramyocellular lipids.

    abstract::Aim of the study was to determine distribution and depletion patterns of intramyocellular lipids (IMCL) in leg muscles before and after two types of standardized endurance exercise. ¹H-magnetic resonance spectroscopic imaging was performed (1) in the thigh of eight-trained cyclists after exercising on an ergometer for...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24168

    authors: Vermathen P,Saillen P,Boss A,Zehnder M,Boesch C

    更新日期:2012-11-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • EPR spectrometer for clinical applications.

    abstract::This article describes an EPR spectrometer specifically designed and constructed for EPR spectroscopy in humans. The spectrometer is based on a permanent magnet, suitable for measurements at 1200 MHz. The magnet has a full 50 cm gap between the poles, which facilitates accurate and comfortable placement of the subject...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20689

    authors: Salikhov I,Walczak T,Lesniewski P,Khan N,Iwasaki A,Comi R,Buckey J,Swartz HM

    更新日期:2005-11-01 00:00:00

  • Pattern recognition of MRSI data shows regions of glioma growth that agree with DTI markers of brain tumor infiltration.

    abstract::Gliomas are the most common primary brain tumors and the majority are highly malignant, with one of the worst prognoses for patients. Gliomas are characterized by invasive growth into normal brain tissue that makes complete surgical resection and accurate radiotherapy planning extremely difficult. We have performed in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22163

    authors: Wright AJ,Fellows G,Byrnes TJ,Opstad KS,McIntyre DJ,Griffiths JR,Bell BA,Clark CA,Barrick TR,Howe FA

    更新日期:2009-12-01 00:00:00

  • Optimized 3D ultrashort echo time pulmonary MRI.

    abstract:PURPOSE:To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS:3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise pe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24570

    authors: Johnson KM,Fain SB,Schiebler ML,Nagle S

    更新日期:2013-11-01 00:00:00

  • A cylindrically symmetric magnetic shield for a large-bore 3.0 Tesla magnet.

    abstract::A 3.0 Tesla, 0.80-m bore magnet replaced our previous 1.9 Tesla, 0.76-m magnet. The 3.0 Tesla replacement magnet had a dipole moment of 1.7 with respect to that of the 1.9 Tesla magnet. The pre-existing cylindrically symmetric passive steel shielding was modified to confine the fringe fields of the replacement magnet ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290319

    authors: Ewing JR,Warner R,Helpern JA

    更新日期:1993-03-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation.

    abstract::A new contrast preparation based on modified driven equilibrium Fourier transfer is introduced and evaluated for generation of T1-weighted images for assessment of the myocardial perfusion with contrast agent first-pass kinetics. The new preparation scheme produces T1 contrast with insensitivity to arrhythmias in pros...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340408

    authors: Tsekos NV,Zhang Y,Merkle H,Wilke N,Jerosch-Herold M,Stillman A,Uğurbil K

    更新日期:1995-10-01 00:00:00

  • Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain.

    abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10204

    authors: Papadakis NG,Martin KM,Mustafa MH,Wilkinson ID,Griffiths PD,Huang CL,Woodruff PW

    更新日期:2002-08-01 00:00:00

  • MRI evaluation of myocardial perfusion without a contrast agent using magnetization transfer.

    abstract::We propose a new magnetic resonance imaging (MRI) technique that is sensitive to myocardial tissue perfusion that obviates the use of an extrinsic contrast agent. Significant advantages of such a technique are that it avoids accumulation of contrast agent when repeated studies are performed on the same subject and tha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300219

    authors: Prasad PV,Burstein D,Edelman RR

    更新日期:1993-08-01 00:00:00

  • Quantitative MRI assessment of leukoencephalopathy.

    abstract::Quantitative MRI assessment of leukoencephalopathy is difficult because the MRI properties of leukoencephalopathy significantly overlap those of normal tissue. This report describes the use of an automated procedure for longitudinal measurement of tissue volume and relaxation times to quantify leukoencephalopathy. Ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10124

    authors: Reddick WE,Glass JO,Langston JW,Helton KJ

    更新日期:2002-05-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen.

    abstract::The feasibility of MR subtraction imaging of lung ventilation using air against oxygen using a multiple inversion recovery half-Fourier single-shot turbo spin echo (MIR-HASTE) sequence was investigated. Eight healthy, nonsmoking volunteers (3 males, 5 females; from 27 to 48 years of age) were studied on a 1.5 T MR uni...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/1522-2594(200006)43:6<913::aid-mrm21>3.0.c

    authors: Mai VM,Chen Q,Bankier AA,Edelman RR

    更新日期:2000-06-01 00:00:00