Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.

Abstract:

:The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform SLR RF pulse design framework that extends most of the capabilities of classical SLR to nonuniform gradient trajectories and multiple dimensions. Specifically, like classical SLR, the new method is a hard pulse approximation-based technique that uses filter design relationships to produce the lowest power RF pulse that satisfies target magnetization ripple levels. The new method is validated and compared with methods conventionally used for nonuniform and multidimensional large-tip-angle RF pulse design.

journal_name

Magn Reson Med

authors

Grissom WA,McKinnon GC,Vogel MW

doi

10.1002/mrm.23269

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

690-702

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

68

pub_type

杂志文章
  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • fMRI of auditory stimulation with intermolecular double-quantum coherences (iDQCs) at 1.5T.

    abstract::An intermolecular double-quantum coherence (iDQC) imaging technique was used to study auditory activation in the human brain at 1.5T with a dual temporal lobe surface phased array coil and a quadrature head coil. Preliminary results demonstrate that it is feasible to obtain auditory activation maps using iDQC imaging ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<356::aid-mrm1046>3.0

    authors: Zhong J,Kwok E,Chen Z

    更新日期:2001-03-01 00:00:00

  • MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

    abstract::In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20108

    authors: Zuehlsdorff S,Umathum R,Volz S,Hallscheidt P,Fink C,Semmler W,Bock M

    更新日期:2004-07-01 00:00:00

  • Analytical solution and verification of diffusion effect in SSFP.

    abstract::Assuming that the SSFP magnetization response maintains a steady state which is periodic in the presence of diffusion, we can solve for the diffusion effect in such sequences. Formulating a Fourier series decomposition solution to the Bloch-Torrey equation and imposing the steady-state condition, analytical expression...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190209

    authors: Carney CE,Wong ST,Patz S

    更新日期:1991-06-01 00:00:00

  • Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity.

    abstract::A methodology is presented for estimating T(1) using a two-point technique with a standard multislice gradient echo sequence. The method explicitly corrects for the shape of the RF pulse and for spatial variations in transmitted RF field intensity. Including these factors in the calculation of T(1) gives a substantial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1112

    authors: Parker GJ,Barker GJ,Tofts PS

    更新日期:2001-05-01 00:00:00

  • B factor dependence of the temporal characteristics of brain activation using dynamic apparent diffusion coefficient contrast.

    abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20293

    authors: Harshbarger TB,Song AW

    更新日期:2004-12-01 00:00:00

  • Chemically induced analgesic nephropathy in the rat monitored by proton-electron double-resonance imaging (PEDRI).

    abstract::Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl carboxylic acid (PCA) through normal and injured kidneys in the living rat. Kidney damage was induced by treatment with 2-bromoethylamine (BEA), which provides a well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400214

    authors: Seimenis I,Foster MA,Lurie DJ,Hutchison JM,Whiting PH,Payne S

    更新日期:1998-08-01 00:00:00

  • Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart.

    abstract::Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal relaxation rate, and could t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1188

    authors: Larsson HB,Rosenbaum S,Fritz-Hansen T

    更新日期:2001-08-01 00:00:00

  • Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

    abstract::Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppress...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300511

    authors: Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

    更新日期:1993-11-01 00:00:00

  • Mapping of regional lung microstructural parameters using hyperpolarized 129 Xe dissolved-phase MRI in healthy volunteers and patients with chronic obstructive pulmonary disease.

    abstract:PURPOSE:To develop a novel technique for voxel-based mapping of lung microstructural parameters using hyperpolarized 129 Xe dissolved-phase MR imaging during saturation recovery. METHODS:A pulse sequence using a highly undersampled stack-of-stars trajectory was developed, and low-rank plus sparse matrix decomposition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27559

    authors: Kern AL,Gutberlet M,Voskrebenzev A,Klimeš F,Rotärmel A,Wacker F,Hohlfeld JM,Vogel-Claussen J

    更新日期:2019-04-01 00:00:00

  • SMS-HSL: Simultaneous multislice aliasing separation exploiting hankel subspace learning.

    abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26527

    authors: Park S,Park J

    更新日期:2017-10-01 00:00:00

  • Simultaneous multi-site EPR spectroscopy in vivo.

    abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300210

    authors: Smirnov AI,Norby SW,Clarkson RB,Walczak T,Swartz HM

    更新日期:1993-08-01 00:00:00

  • REKINDLE: robust extraction of kurtosis INDices with linear estimation.

    abstract:PURPOSE:Recent literature shows that diffusion tensor properties can be estimated more accurately with diffusion kurtosis imaging (DKI) than with diffusion tensor imaging (DTI). Furthermore, the additional non-Gaussian diffusion features from DKI can be sensitive markers for tissue characterization. Despite these benef...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25165

    authors: Tax CM,Otte WM,Viergever MA,Dijkhuizen RM,Leemans A

    更新日期:2015-02-01 00:00:00

  • Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

    abstract:PURPOSE:To develop a fast protocol for measuring T1 values in the internal carotid artery (ICA), to validate this technique with in vitro measurements, and to evaluate its reproducibility. METHODS:A modified Look-Locker sequence was optimized to enable rapid determination of T1 in the ICA at 3T. T1 values from the ICA...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26325

    authors: Li W,Liu P,Lu H,Strouse JJ,van Zijl PCM,Qin Q

    更新日期:2017-06-01 00:00:00

  • In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques.

    abstract::A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear pol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10392

    authors: Foster MA,Grigor'ev IA,Lurie DJ,Khramtsov VV,McCallum S,Panagiotelis I,Hutchison JM,Koptioug A,Nicholson I

    更新日期:2003-03-01 00:00:00

  • Cardiac perfusion imaging using hyperpolarized (13)C urea using flow sensitizing gradients.

    abstract:PURPOSE:To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized (13)C urea through the rodent heart using flow-sensitizing gradients to reduce signal from the blood pool. METHODS:A flow-sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25713

    authors: Lau AZ,Miller JJ,Robson MD,Tyler DJ

    更新日期:2016-04-01 00:00:00

  • Direct CSF injection of MnCl(2) for dynamic manganese-enhanced MRI.

    abstract::MnCl(2) was injected intrathecally through the cisterna magna in rats, allowing infusion of divalent manganese ions (Mn(++)) into the CSF space and thence into the brain, without breaking the blood-brain barrier (BBB). Mn(++) uptake and washout dynamics in the brain were measured by serial T(1)-weighted MRI and EPI T(...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20047

    authors: Liu CH,D'Arceuil HE,de Crespigny AJ

    更新日期:2004-05-01 00:00:00

  • High-resolution FMRI at 1.5T using balanced SSFP.

    abstract::The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20753

    authors: Miller KL,Smith SM,Jezzard P,Pauly JM

    更新日期:2006-01-01 00:00:00

  • A new approach to Z-spectrum acquisition: prospective baseline enhancement (PROBE) for CEST/Nuclear Overhauser Effect.

    abstract:PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27555

    authors: Lenich T,Pampel A,Mildner T,Möller HE

    更新日期:2019-04-01 00:00:00

  • Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

    abstract:PURPOSE:To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS:A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image si...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24958

    authors: Chen D,Sharif B,Dharmakumar R,Thomson LE,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-09-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Investigating temporal fluctuations in tumor vasculature with combined carbogen and ultrasmall superparamagnetic iron oxide particle (CUSPIO) imaging.

    abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22779

    authors: Burrell JS,Walker-Samuel S,Baker LC,Boult JK,Ryan AJ,Waterton JC,Halliday J,Robinson SP

    更新日期:2011-07-01 00:00:00

  • Imaging articular cartilage under compression--cartilage elastography.

    abstract::We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20439

    authors: Hardy PA,Ridler AC,Chiarot CB,Plewes DB,Henkelman RM

    更新日期:2005-05-01 00:00:00

  • Correction for partial volume errors in MR heart perfusion imaging.

    abstract::Myocardial MR first-pass perfusion time courses are contaminated by signals from the ventricles (spillover) as a consequence of partial volume effects and motion. An early increase in the signal intensity from the myocardium is an indicator of contamination. This contamination leads to under- or overestimation of perf...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20015

    authors: Köstler H,Ritter C,Reiss-Zimmermann M,Beer M,Hahn D,Sandstede J

    更新日期:2004-04-01 00:00:00

  • Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE.

    abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25729

    authors: Rioux JA,Levesque IR,Rutt BK

    更新日期:2016-06-01 00:00:00

  • Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

    abstract::Chemical exchange saturation transfer (CEST) and spin-locking (SL) experiments were both able to probe the exchange process between protons of nonequivalent chemical environments. To compare the characteristics of the CEST and SL approaches in the study of chemical exchange effects, we performed CEST and SL experiment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22721

    authors: Jin T,Autio J,Obata T,Kim SG

    更新日期:2011-05-01 00:00:00

  • Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone.

    abstract::Cortical bone in the mature skeleton has a short T(2)* and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (UTE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 micros and is capable of detecting ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21397

    authors: Du J,Hamilton G,Takahashi A,Bydder M,Chung CB

    更新日期:2007-11-01 00:00:00

  • Regional comparison of tumor vascularity and permeability parameters measured by albumin-Gd-DTPA and Gd-DTPA.

    abstract::Sequential albumin-Gd-DTPA and Gd-DTPA dynamic enhancement studies were performed in an animal tumor model for the comparison of regional vascularity and permeability parameters measured by these two different sizes of contrast agents. The early albumin-Gd-DTPA enhancement arises from the vascular compartment, and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340318

    authors: Su MY,Najafi AA,Nalcioglu O

    更新日期:1995-09-01 00:00:00

  • Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequences.

    abstract::In order to obtain proton magnetic resonance spectra from the normal human kidney in vivo, we employed a STEAM sequence with delay times TE = 10 ms and TM = 30 ms. Signals are attenuated during STEAM sequences by J-coupling effects and by macroscopic movement of the sample. The combination of short echo times and resp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310503

    authors: Dixon RM,Frahm J

    更新日期:1994-05-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00