On multiple alternating steady states induced by periodic spin phase perturbation waveforms.

Abstract:

:Direct measurement of neural currents by means of MRI can potentially open a high temporal resolution (10-100 ms) window applicable for monitoring dynamics of neuronal activity without loss of the high spatial resolution afforded by MRI. Previously, we have shown that the alternating balanced steady state imaging affords high sensitivity to weak periodic currents owing to its amplification of periodic spin phase perturbations. This technique, however, requires precise synchronization of such perturbations to the radiofrequency pulses. Herein, we extend alternating balanced steady state imaging to multiple balanced alternating steady states for estimation of neural current waveforms. Simulations and phantom experiments show that the off-resonance profile of the multiple alternating steady state signal carries information about the frequency content of driving waveforms. In addition, the method is less sensitive than alternating balanced steady state to precise waveform timing relative to radiofrequency pulses. Thus, multiple alternating steady state technique is potentially applicable to MR imaging of the waveforms of periodic neuronal activity.

journal_name

Magn Reson Med

authors

Buračas GT,Jung Y,Lee J,Buxton RB,Wong EC,Liu TT

doi

10.1002/mrm.23105

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

1412-8

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

67

pub_type

杂志文章
  • Effect of feature extraction for brain tumor classification based on short echo time 1H MR spectra.

    abstract::This study examines the effect of feature extraction methods prior to automated pattern recognition based on magnetic resonance spectroscopy (MRS) for brain tumor diagnosis. Since individual inspection of spectra is time-consuming and requires specific spectroscopic expertise, the introduction of clinical decision sup...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21626

    authors: Luts J,Poullet JB,Garcia-Gomez JM,Heerschap A,Robles M,Suykens JA,Van Huffel S

    更新日期:2008-08-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Real-time cardiovascular MR with spatio-temporal artifact suppression using deep learning-proof of concept in congenital heart disease.

    abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27480

    authors: Hauptmann A,Arridge S,Lucka F,Muthurangu V,Steeden JA

    更新日期:2019-02-01 00:00:00

  • Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate.

    abstract::In radiotherapy, target tissues are defined best on MR images due to their superior soft tissue contrast. Computed tomography imaging is geometrically accurate and it is needed for dose calculation and generation of reference images for treatment localization. Co-registration errors between MR and computed tomography ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,随机对照试验

    doi:10.1002/mrm.24459

    authors: Kapanen M,Collan J,Beule A,Seppälä T,Saarilahti K,Tenhunen M

    更新日期:2013-07-01 00:00:00

  • An automated tool for cortical feature analysis: Application to differences on 7 Tesla T2* -weighted images between young and older healthy subjects.

    abstract:PURPOSE:High field T2* -weighted MR images of the cerebral cortex are increasingly used to study tissue susceptibility changes related to aging or pathologies. This paper presents a novel automated method for the computation of quantitative cortical measures and group-wise comparison using 7 Tesla T2* -weighted magnitu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25397

    authors: Doan NT,van Rooden S,Versluis MJ,Buijs M,Webb AG,van der Grond J,van Buchem MA,Reiber JHC,Milles J

    更新日期:2015-07-01 00:00:00

  • Single-scan MRI with exceptional resilience to field heterogeneities.

    abstract:PURPOSE:Single-scan two-dimensional MRI has been generally constrained to acquisitions in high quality magnets. This study introduces a methodology, cross-term spatiotemporal encoding (xSPEN), that delivers such images under much poorer external field conditions. METHODS:xSPEN departs from conventional k-space scannin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26145

    authors: Zhang Z,Seginer A,Frydman L

    更新日期:2017-02-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

    abstract::We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by opti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320416

    authors: Felblinger J,Lehmann C,Boesch C

    更新日期:1994-10-01 00:00:00

  • CINE turbo spin echo imaging.

    abstract::High-resolution turbo spin echo (TSE) images have demonstrated important details of carotid artery morphology; however, it is evident that pulsatile blood and wall motion related to the cardiac cycle are still significant sources of image degradation. Although ECG gating can reduce artifacts due to cardiac-induced pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22909

    authors: Mendes J,Parker DL,Hulet J,Treiman GS,Kim SE

    更新日期:2011-11-01 00:00:00

  • Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H(2)(15)O PET measurements.

    abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0

    authors: Liu HL,Kochunov P,Hou J,Pu Y,Mahankali S,Feng CM,Yee SH,Wan YL,Fox PT,Gao JH

    更新日期:2001-03-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

    abstract::The integrated T(1)-T(2) characteristics of rat brain and trigeminal nerve water were studied in vivo using a rapid method for acquiring a series of images that depend on T(1) and T(2) relaxation times. Gray matter regions showed only one signal component in both the T(1) and T(2) domains. Trigeminal nerve, however, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10060

    authors: Does MD,Gore JC

    更新日期:2002-02-01 00:00:00

  • In vivo MRI of fresh stored osteochondral allograft transplantation with delayed gadolinium-enhanced MRI of cartilage: protocol considerations and recommendations.

    abstract::The protocol for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) was adapted for the evaluation of transplanted osteochondral allograft cartilage. Eight patients with focal grade 4 cartilage defects of the femoral condyle were treated with single cylindrical osteochondral allografts. At 1 and 2 years, dGEMRIC i...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24419

    authors: Durkan MG,Szumowski J,Brown DS,Foss EW,Crawford DC

    更新日期:2013-06-01 00:00:00

  • India ink: a potential clinically applicable EPR oximetry probe.

    abstract::Using a material that already is in widespread use in humans, India ink, the first EPR measurements in a human have been made, using the India ink in a pre-existing tattoo. The EPR spectra of India ink are very sensitive to the partial pressure of oxygen (pO2), thereby making it feasible to use this approach to measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310218

    authors: Swartz HM,Liu KJ,Goda F,Walczak T

    更新日期:1994-02-01 00:00:00

  • Efficient biphasic spin-echo magnetic resonance imaging.

    abstract::The concept of temporal echo multiplexing is defined and used to develop rapid biphasic spin-echo sequences for imaging the heart. Three imaging sequences, based on four-echo and two-echo multiplexing and rapid single echo (i.e., conventional spin-echo imaging), are compared. Preliminary results indicate that two-echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110109

    authors: Parker DL,Caputo GR,Frederick PR

    更新日期:1989-07-01 00:00:00

  • In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques.

    abstract::A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear pol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10392

    authors: Foster MA,Grigor'ev IA,Lurie DJ,Khramtsov VV,McCallum S,Panagiotelis I,Hutchison JM,Koptioug A,Nicholson I

    更新日期:2003-03-01 00:00:00

  • Sensitivity of MR diffusion measurements to variations in intracellular structure: effects of nuclear size.

    abstract::Magnetic resonance imaging measurements of the apparent rate of water diffusion in tumors are sensitive to variations in tissue cellularity, which have been shown useful for characterizing tumors and their responses to treatments. However, because of technical limitations on most MRI systems, conventional pulse gradie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21793

    authors: Xu J,Does MD,Gore JC

    更新日期:2009-04-01 00:00:00

  • Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

    abstract::In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position wa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10390

    authors: Peters DC,Lederman RJ,Dick AJ,Raman VK,Guttman MA,Derbyshire JA,McVeigh ER

    更新日期:2003-02-01 00:00:00

  • Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T.

    abstract:PURPOSE:To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS:Measurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequenc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27038

    authors: Jaeschke SHF,Robson MD,Hess AT

    更新日期:2018-08-01 00:00:00

  • Kinetic modeling of hyperpolarized (13)C pyruvate metabolism in tumors using a measured arterial input function.

    abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24546

    authors: Kazan SM,Reynolds S,Kennerley A,Wholey E,Bluff JE,Berwick J,Cunningham VJ,Paley MN,Tozer GM

    更新日期:2013-10-01 00:00:00

  • A 7Li NMR study of visibility, spin relaxation, and transport in normal human erythrocytes.

    abstract::The behavior of the lithium (Li) ion in normal human erythrocytes has been studied by 7Li NMR. The uptake of Li into the cells was followed as a function of solution conditions, temperature, hematocrit, and blood age using dysprosium tripolyphosphate shift reagent. Under our conditions the uptake of Li increases with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200207

    authors: Gullapalli RP,Hawk RM,Komoroski RA

    更新日期:1991-08-01 00:00:00

  • Quantitative MRI assessment of leukoencephalopathy.

    abstract::Quantitative MRI assessment of leukoencephalopathy is difficult because the MRI properties of leukoencephalopathy significantly overlap those of normal tissue. This report describes the use of an automated procedure for longitudinal measurement of tissue volume and relaxation times to quantify leukoencephalopathy. Ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10124

    authors: Reddick WE,Glass JO,Langston JW,Helton KJ

    更新日期:2002-05-01 00:00:00

  • Designing hyperbolic secant excitation pulses to reduce signal dropout in gradient-echo echo-planar imaging.

    abstract:PURPOSE:To design hyperbolic secant (HS) excitation pulses to reduce signal dropout in the orbitofrontal and inferior temporal regions in gradient-echo echo-planar imaging (GE-EPI) for functional MRI (fMRI) applications. METHODS:An algorithm based on Bloch simulations optimizes the HS pulse parameters needed to give t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25444

    authors: Wastling SJ,Barker GJ

    更新日期:2015-09-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • MRI reconstruction using deep Bayesian estimation.

    abstract:PURPOSE:To develop a deep learning-based Bayesian estimation for MRI reconstruction. METHODS:We modeled the MRI reconstruction problem with Bayes's theorem, following the recently proposed PixelCNN++ method. The image reconstruction from incomplete k-space measurement was obtained by maximizing the posterior possibili...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28274

    authors: Luo G,Zhao N,Jiang W,Hui ES,Cao P

    更新日期:2020-10-01 00:00:00

  • 31P NMR spectroscopy of 9L cell line in culture: differential effects of high temperature on anchored cells and spheroids.

    abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190233

    authors: Suzuki N,Kwee IL,Tamas LB,Nakada T

    更新日期:1991-06-01 00:00:00

  • Experimental encephalomyelitis modulates inositol and taurine in the spinal cord of Biozzi mice.

    abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320603

    authors: Preece NE,Amor S,Baker D,Gadian DG,O'Neill JK,Urenjak J

    更新日期:1994-12-01 00:00:00

  • Correction of motion-induced susceptibility artifacts and B0 drift during proton resonance frequency shift-based MR thermometry in the pelvis with background field removal methods.

    abstract:PURPOSE:The linear change of the water proton resonance frequency shift (PRFS) with temperature is used to monitor temperature change based on the temporal difference of image phase. Here, the effect of motion-induced susceptibility artifacts on the phase difference was studied in the context of mild radio frequency hy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28302

    authors: Wu M,Mulder HT,Baron P,Coello E,Menzel MI,van Rhoon GC,Haase A

    更新日期:2020-11-01 00:00:00

  • Functional magnetic resonance electrical impedance tomography (fMREIT) sensitivity analysis using an active bidomain finite-element model of neural tissue.

    abstract:PURPOSE:A direct method of imaging neural activity was simulated to determine typical signal sizes. METHODS:An active bidomain finite-element model was used to estimate approximate perturbations in MR phase data as a result of neural tissue activity, and when an external MR electrical impedance tomography imaging curr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27351

    authors: Sadleir RJ,Fu F,Chauhan M

    更新日期:2019-01-01 00:00:00