A 7Li NMR study of visibility, spin relaxation, and transport in normal human erythrocytes.

Abstract:

:The behavior of the lithium (Li) ion in normal human erythrocytes has been studied by 7Li NMR. The uptake of Li into the cells was followed as a function of solution conditions, temperature, hematocrit, and blood age using dysprosium tripolyphosphate shift reagent. Under our conditions the uptake of Li increases with increasing hematocrit and blood age. For packed cells the extracellular 7Li spin-lattice relaxation time was only slightly longer than the intracellular relaxation time. Thus, T1 may not be useful for separate observation of intra- and extracellular Li in vivo. The intra- and extracellular T2s were substantially shorter than the corresponding T1s. Also, the intracellular T2 was considerably shorter than that for the extracellular compartment, suggesting that T2 may provide a noninvasive handle for observation of intracellular Li. Nuclear Overhauser enhancements could be observed for both extra- and intracellular 7Li, confirming that dipolar coupling to 1H is a contributing relaxation mechanism. The 7Li NMR visibility was essentially 100% at high Li concentrations, decreasing to about 84% at 1 mM Li. Based on time course studies of the invisibility, and a comparison of NMR and inductively coupled plasma results, it appears that the invisibility of the intra- and extracellular compartments for packed cells is the same. Although a 23Na double-quantum signal could be observed for red blood cells, no double-quantum signal was observed for 7Li.

journal_name

Magn Reson Med

authors

Gullapalli RP,Hawk RM,Komoroski RA

doi

10.1002/mrm.1910200207

subject

Has Abstract

pub_date

1991-08-01 00:00:00

pages

240-52

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

20

pub_type

杂志文章
  • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

    abstract::An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20547

    authors: Wiggins GC,Potthast A,Triantafyllou C,Wiggins CJ,Wald LL

    更新日期:2005-07-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • Molecular imaging of angiogenic therapy in peripheral vascular disease with alphanubeta3-integrin-targeted nanoparticles.

    abstract::Noninvasive molecular imaging of angiogenesis could play a critical role in the clinical management of peripheral vascular disease patients. The alpha(nu)beta(3)-integrin, a well-established biomarker of neovascular proliferation, is an ideal target for molecular imaging of angiogenesis. This study investigates whethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22447

    authors: Winter PM,Caruthers SD,Allen JS,Cai K,Williams TA,Lanza GM,Wickline SA

    更新日期:2010-08-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Self-degrading, MRI-detectable hydrogel sensors with picomolar target sensitivity.

    abstract::Nanostructured hydrogels have been developed as synthetic tissues and scaffolds for cell and drug delivery, and as guides for tissue regeneration. A fundamental problem in the development of synthetic hydrogels is that implanted gel structure is difficult to monitor noninvasively. This work demonstrates that the aggre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22570

    authors: Colomb J,Louie K,Massia SP,Bennett KM

    更新日期:2010-12-01 00:00:00

  • Functional mapping of the human somatosensory cortex with echo-planar MRI.

    abstract::The somatotopical organization of the human somatosensory cortex was analyzed with echo-planar imaging at 1.5 Tesla, utilizing deoxyhemoglobin as an endogenous contrast medium. Scrubbing stimulation at a frequency of 3 Hz was applied to one of three cutaneous areas: toes, fingertips, and tongue tip. Parasagittal echo-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330521

    authors: Sakai K,Watanabe E,Onodera Y,Itagaki H,Yamamoto E,Koizumi H,Miyashita Y

    更新日期:1995-05-01 00:00:00

  • Cellular imaging and texture analysis distinguish differences in cellular dynamics in mouse brain tumors.

    abstract:PURPOSE:The heterogeneous tumor cell population and dynamic microenvironment within a tumor lead to regional variations in cell proliferation, migration, and differentiation. In this work, MRI and optical projection tomography were used to examine and compare the redistribution of a cellular label in two mouse glioma m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24790

    authors: Gazdzinski LM,Nieman BJ

    更新日期:2014-04-01 00:00:00

  • MR microimaging of articular cartilage and contrast enhancement by manganese ions.

    abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240114

    authors: Kusaka Y,Gründer W,Rumpel H,Dannhauer KH,Gersonde K

    更新日期:1992-03-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • In vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2.

    abstract::Follow-up T(1)-weighted 3D gradient-echo MRI (2.35 T) of murine brain in vivo (N = 5) at 120 microm isotropic resolution revealed spatially distinct signal increases 6-48 hr after subcutaneous application of MnCl(2) (20 mg/kg). The effects result from a shortening of the water proton T(1) relaxation time due to the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10276

    authors: Watanabe T,Natt O,Boretius S,Frahm J,Michaelis T

    更新日期:2002-11-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25848

    authors: Sengupta S,Smith DS,Gifford A,Welch EB

    更新日期:2016-07-01 00:00:00

  • Retrospective artifact elimination in MEGA-PRESS using a correlation approach.

    abstract:PURPOSE:To develop a method for retrospective artifact elimination of MRS data. This retrospective method was based on an approach that combines jackknife analyses with the correlation of spectral windows, and therefore termed "JKC." METHODS:Twelve healthy volunteers performed 3 separate measurement protocols using a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27590

    authors: Tapper S,Tisell A,Helms G,Lundberg P

    更新日期:2019-04-01 00:00:00

  • Ultra-rapid gradient echo imaging.

    abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330123

    authors: Heid O,Deimling M,Huk WJ

    更新日期:1995-01-01 00:00:00

  • Fully balanced steady-state 3D-spin-echo (bSSSE) imaging at 3 Tesla.

    abstract::In this work a 3D fully balanced steady-state spin-echo sequence (bSSSE) was designed and implemented on a 3-Tesla whole-body MR scanner. In contrast to previously introduced nonbalanced SSSE (nbSSSE) sequences, bSSSE features fully rewound imaging gradients. Additionally, all phase encodings and the readout prephasin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21037

    authors: Krug R,Han ET,Banerjee S,Majumdar S

    更新日期:2006-11-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Perfusion mapping with multiecho multishot parallel imaging EPI.

    abstract::Echo-planar imaging (EPI) is the standard technique for dynamic susceptibility-contrast (DSC) perfusion MRI. However, EPI suffers from well-known geometric distortions, which can be reduced by increasing the k-space phase velocity. Moreover, the long echo times (TEs) used in DSC lead to signal saturation of the arteri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21255

    authors: Newbould RD,Skare ST,Jochimsen TH,Alley MT,Moseley ME,Albers GW,Bammer R

    更新日期:2007-07-01 00:00:00

  • Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    abstract:PURPOSE:Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25074

    authors: Sharif B,Dharmakumar R,Arsanjani R,Thomson L,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-12-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • Oxygen extraction fraction mapping at 3 Tesla using an artificial neural network: A feasibility study.

    abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26749

    authors: Domsch S,Mürle B,Weingärtner S,Zapp J,Wenz F,Schad LR

    更新日期:2018-02-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    abstract:PURPOSE:To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). METHODS:The effects of imaging gradients in FEXI were observed on yea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26856

    authors: Lasič S,Lundell H,Topgaard D,Dyrby TB

    更新日期:2018-04-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • Deuterium magnetic resonance imaging of rabbit eye in vivo.

    abstract::We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330417

    authors: Obata T,Ikehira H,Koga M,Yoshida K,Kimura F,Tateno Y

    更新日期:1995-04-01 00:00:00

  • Quantitative measurement of regional lung ventilation using 3He MRI.

    abstract::A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10206

    authors: Deninger AJ,Månsson S,Petersson JS,Pettersson G,Magnusson P,Svensson J,Fridlund B,Hansson G,Erjefeldt I,Wollmer P,Golman K

    更新日期:2002-08-01 00:00:00

  • Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.

    abstract:PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24639

    authors: Zong X,Wang P,Kim SG,Jin T

    更新日期:2014-01-01 00:00:00

  • Electromagnetic fields of surface coil in vivo NMR at high frequencies.

    abstract::A high frequency solution of the electromagnetic field produced by a circular surface coil adjacent to a homogeneous conducting, dielectric sphere is used to predict the attainable signal to noise ratio (S/N) and specific absorption rate (SAR) for in vivo 1H NMR spectroscopy experiments from 200 to 430 MHz (4.7-10 T)....

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220254

    authors: Keltner JR,Carlson JW,Roos MS,Wong ST,Wong TL,Budinger TF

    更新日期:1991-12-01 00:00:00