Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

Abstract:

:The integrated T(1)-T(2) characteristics of rat brain and trigeminal nerve water were studied in vivo using a rapid method for acquiring a series of images that depend on T(1) and T(2) relaxation times. Gray matter regions showed only one signal component in both the T(1) and T(2) domains. Trigeminal nerve, however, which has been shown previously to exhibit three T(2) components, was found to also exhibit three T(1) components. The correlations between these T(1) and T(2) components were demonstrated by uniquely filtering out each of the three T(2) components using an inversion-recovery preparation, as determined by the component T(1) values. Based on previous works, it is postulated that each of these three signal components is derived from a unique microanatomical region of the nerve. Knowledge of these T(1) components may thus prove valuable in devising novel methods of identifying the presence and quantifying the volume of tissue subtypes such as myelin.

journal_name

Magn Reson Med

authors

Does MD,Gore JC

doi

10.1002/mrm.10060

subject

Has Abstract

pub_date

2002-02-01 00:00:00

pages

274-83

issue

2

eissn

0740-3194

issn

1522-2594

pii

10.1002/mrm.10060

journal_volume

47

pub_type

杂志文章
  • Boron-11 NMR of borocaptate: relaxation and in vivo detection in melanoma-bearing mice.

    abstract::Longitudinal and transverse relaxation rates for the 11B resonances in sodium borocaptate (BSH) at varying concentrations were measured in undiluted horse serum in a 4.7 Tesla field. The results could be fit by a model that assumes fast exchange of the BSH molecule between a free and a bound state, using values of 0.7...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390314

    authors: Bendel P,Frantz A,Zilberstein J,Kabalka GW,Salomon Y

    更新日期:1998-03-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • Robust fully automated shimming of the human brain for high-field 1H spectroscopic imaging.

    abstract::Although a variety of methods have been proposed to provide automated adjustment of shim homogeneity, these methods typically fail or require large numbers of iterations in vivo when applied to regions with poor homogeneity, such as the temporal lobe. These limitations are largely due to 1) the limited accuracy of sin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20941

    authors: Hetherington HP,Chu WJ,Gonen O,Pan JW

    更新日期:2006-07-01 00:00:00

  • Determining the extent to which delayed-enhancement images reflect the partition-coefficient of Gd-DTPA in canine studies of reperfused and unreperfused myocardial infarction.

    abstract::MRI after a constant infusion (CI) of Gd-DTPA has been used to identify the extent of myocardial infarction (MI). However, Gd-DTPA-enhanced "viability" imaging is more commonly performed with a bolus (for "delayed-enhancement" (DE) imaging). This study sought to determine how image delay time and time postinfarction i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20236

    authors: Thornhill RE,Prato FS,Wisenberg G,Moran GR,Sykes J

    更新日期:2004-11-01 00:00:00

  • Investigating temporal fluctuations in tumor vasculature with combined carbogen and ultrasmall superparamagnetic iron oxide particle (CUSPIO) imaging.

    abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22779

    authors: Burrell JS,Walker-Samuel S,Baker LC,Boult JK,Ryan AJ,Waterton JC,Halliday J,Robinson SP

    更新日期:2011-07-01 00:00:00

  • Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.

    abstract::The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21168

    authors: Ishii M,Emami K,Kadlecek S,Petersson JS,Golman K,Vahdat V,Yu J,Cadman RV,MacDuffie-Woodburn J,Stephen M,Lipson DA,Rizi RR

    更新日期:2007-03-01 00:00:00

  • PLANET: An ellipse fitting approach for simultaneous T1 and T2 mapping using phase-cycled balanced steady-state free precession.

    abstract:PURPOSE:To demonstrate the feasibility of a novel, ellipse fitting approach, named PLANET, for simultaneous estimation of relaxation times T1 and T2 from a single 3D phase-cycled balanced steady-state free precession (bSSFP) sequence. METHODS:A method is presented in which the elliptical signal model is used to descri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26717

    authors: Shcherbakova Y,van den Berg CAT,Moonen CTW,Bartels LW

    更新日期:2018-02-01 00:00:00

  • In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

    abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22037

    authors: Mitsouras D,Owens CD,Conte MS,Ersoy H,Creager MA,Rybicki FJ,Mulkern RV

    更新日期:2009-09-01 00:00:00

  • Evaluation of MRI resolution affecting trabecular bone parameters: determination of acceptable resolution.

    abstract::The objective of this study is to evaluate the effect of MR image resolution on trabecular bone parameters and to determine the acceptable resolution that can be accurately analyzed to assess structural parameters. Ten distal femoral condyle specimens of 1 × 1 × 1 cm(3) were scanned with a 4.7-T Bruker BioSpec MRI sca...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22984

    authors: Kim N,Lee JG,Song Y,Kim HJ,S Yeom J,Cho G

    更新日期:2012-01-01 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Clinical prostate T2 quantification using magnetization-prepared spiral imaging.

    abstract::T(2) quantification may augment diagnostic T(2)-weighted imaging; to improve cancer detection via auto-segmentation of multi-parametric acquisitions and to potentiate longitudinal studies of prostate cancer. However, robust quantitative techniques are not generally accessible or refined for clinical translation. This ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22492

    authors: Foltz WD,Chopra S,Chung P,Bayley A,Catton C,Jaffray D,Wright GA,Haider MA,Ménard C

    更新日期:2010-10-01 00:00:00

  • Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

    abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21345

    authors: Stalder AF,Elverfeldt DV,Paul D,Hennig J,Markl M

    更新日期:2008-01-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Synchronous MRI of muscle motion induced by electrical stimulation.

    abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26154

    authors: Deligianni X,Pansini M,Garcia M,Hirschmann A,Schmidt-Trucksäss A,Bieri O,Santini F

    更新日期:2017-02-01 00:00:00

  • Counter rotating current local coils for high-resolution magnetic resonance imaging.

    abstract::A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030412

    authors: Froncisz W,Jesmanowicz A,Kneeland JB,Hyde JS

    更新日期:1986-08-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Comparison of diffusion- and T2-weighted MRI for the early detection of cerebral ischemia and reperfusion in rats.

    abstract::The sensitivity of diffusion-weighted MRI was compared to that of T2-weighted MRI following temporary middle cerebral artery occlusion (MCA-O) for 33 min followed by 4 h of reperfusion in rats. Diffusion-weighted spin-echo images using strong gradients (b value of 1413 s/mm2) demonstrated a significant increase in sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180106

    authors: Mintorovitch J,Moseley ME,Chileuitt L,Shimizu H,Cohen Y,Weinstein PR

    更新日期:1991-03-01 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00

  • T2 relaxation reveals spatial collagen architecture in articular cartilage: a comparative quantitative MRI and polarized light microscopic study.

    abstract::It has been suggested that orientational changes in the collagen network of articular cartilage account for the depthwise T2 anisotropy of MRI through the magic angle effect. To investigate the relationship between laminar T2 appearance and collagen organization (anisotropy), bovine osteochondral plugs (N = 9) were T2...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1218

    authors: Nieminen MT,Rieppo J,Töyräs J,Hakumäki JM,Silvennoinen J,Hyttinen MM,Helminen HJ,Jurvelin JS

    更新日期:2001-09-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    abstract:PURPOSE:Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25074

    authors: Sharif B,Dharmakumar R,Arsanjani R,Thomson L,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-12-01 00:00:00

  • Functional mapping of the human somatosensory cortex with echo-planar MRI.

    abstract::The somatotopical organization of the human somatosensory cortex was analyzed with echo-planar imaging at 1.5 Tesla, utilizing deoxyhemoglobin as an endogenous contrast medium. Scrubbing stimulation at a frequency of 3 Hz was applied to one of three cutaneous areas: toes, fingertips, and tongue tip. Parasagittal echo-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330521

    authors: Sakai K,Watanabe E,Onodera Y,Itagaki H,Yamamoto E,Koizumi H,Miyashita Y

    更新日期:1995-05-01 00:00:00

  • Intimate combination of low- and high-resolution image data: I. Real-space PET and (1)H(2)O MRI, PETAMRI.

    abstract::Two different types of (co-registered) images of the same slice of tissue will generally have different spatial resolutions. The judicious pixel-by-pixel combination of their data can be accomplished to yield a single image exhibiting properties of both. Here, axial (18)FDG PET and (1)H(2)O MR images of the human brai...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199908)42:2<345::aid-mrm17

    authors: Sammi MK,Felder CA,Fowler JS,Lee JH,Levy AV,Li X,Logan J,Pályka I,Rooney WD,Volkow ND,Wang GJ,Springer CS Jr

    更新日期:1999-08-01 00:00:00

  • Ischemia-induced ADC changes are larger than osmotically-induced ADC changes in a neonatal rat hippocampus model.

    abstract::Diffusion-weighted imaging (DWI) is frequently used to diagnose stroke. However, the origin of the observed reduction in the apparent diffusion coefficient (ADC) in the acute phase following ischemia is not well understood. Although cell swelling is considered to play an important role, it is unclear whether this can ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20353

    authors: van Pul C,Jennekens W,Nicolay K,Kopinga K,Wijn PF

    更新日期:2005-02-01 00:00:00

  • In vitro study to simulate the intracardiac magnetohydrodynamic effect.

    abstract:PURPOSE:Blood flow causes induced voltages via the magnetohydrodynamic (MHD) effect distorting electrograms (EGMs) made during magnetic resonance imaging. To investigate the MHD effect in this context MHD voltages occurring inside the human heart were simulated in an in vitro model system inside a 1.5 T MR system. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25456

    authors: Buchenberg WB,Mader W,Hoppe G,Lorenz R,Menza M,Büchert M,Timmer J,Jung B

    更新日期:2015-09-01 00:00:00

  • Accelerated 3D T2 mapping with dictionary-based matching for prostate imaging.

    abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27540

    authors: Roccia E,Vidya Shankar R,Neji R,Cruz G,Munoz C,Botnar R,Goh V,Prieto C,Dregely I

    更新日期:2019-03-01 00:00:00

  • Automated feature extraction for the classification of human in vivo 13C NMR spectra using statistical pattern recognition and wavelets.

    abstract::If magnetic resonance spectroscopy (MRS) is to become a useful tool in clinical medicine, it will be necessary to find reliable methods for analyzing and classifying MRS data. Automated methods are desirable because they can remove user bias and can deal with large amounts of data, allowing the use of all the availabl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350608

    authors: Tate AR,Watson D,Eglen S,Arvanitis TN,Thomas EL,Bell JD

    更新日期:1996-06-01 00:00:00