A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

Abstract:

PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empirical Bayes approach, spatial and temporal redundancies are exploited via sparsity in the wavelet domain, and the voxel-wise magnitude and phase structure across encodings is captured in a conditional mixture prior that applies regularizing constraints based on the presence of flow. We validate the proposed technique using data from a mechanical flow phantom and five healthy volunteers. RESULTS:The flow parameters derived from the proposed technique are in good agreement with those derived from reference datasets for both in vivo and mechanical flow experiments at accelerations rates as high as R = 27. Additionally, the proposed technique outperforms kt SPARSE-SENSE and a method that exploits spatio-temporal sparsity but does not utilize signal structure across encodings. CONCLUSIONS:Using the proposed technique, it is feasible to highly accelerate 4D flow acquisition and thus enable aortic valve imaging within a single breath-hold.

journal_name

Magn Reson Med

authors

Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

doi

10.1002/mrm.27386

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

811-824

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

81

pub_type

杂志文章
  • Commutator filter: a novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRI.

    abstract::A robust postprocessing method to detect regions of magnetic field change is presented. High resolution gradient echo data is acquired to create a complex baseline image. From this image, two low resolution images are obtained by applying a low pass filter on the magnitude image and the complex image, respectively. Su...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360518

    authors: Lai S,Reichenbach JR,Haacke EM

    更新日期:1996-11-01 00:00:00

  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00

  • Cortical hypoperfusion in the B6.PS2APP mouse model for Alzheimer's disease: comprehensive phenotyping of vascular and tissular parameters by MRI.

    abstract::Function and morphology of the cerebral vasculature were studied in the amyloid (Abeta) plaque-containing double-transgenic (TG) B6.PS2APP Alzheimer's disease (AD) mouse model with MRI at an age range of 10 to 17 months. Perfusion, blood volume, and average vessel geometry were assessed in the brain and compared to ag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21985

    authors: Weidensteiner C,Metzger F,Bruns A,Bohrmann B,Kuennecke B,von Kienlin M

    更新日期:2009-07-01 00:00:00

  • Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

    abstract:PURPOSE:Cardiac stimulation (CS) limits to gradient coil switching speed are difficult to measure in humans; instead, current regulatory guidelines (IEC 60601-2-33) are based on animal experiments and electric field-to-dB/dt conversion factors computed for a simple, homogeneous body model. We propose improvement to thi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28472

    authors: Klein V,Davids M,Schad LR,Wald LL,Guérin B

    更新日期:2021-02-01 00:00:00

  • Mapping of redox status in a brain-disease mouse model by three-dimensional EPR imaging.

    abstract::Electron paramagnetic resonance imaging using nitroxides is a powerful method for visualizing the redox status modulated by oxidative stress in vivo. Typically, however, data acquisition times have been too slow to obtain a sufficient number of projections for three-dimensional images, when using continuous wave-elect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22598

    authors: Fujii H,Sato-Akaba H,Kawanishi K,Hirata H

    更新日期:2011-01-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • Differential effect of isoflurane, medetomidine, and urethane on BOLD responses to acute levo-tetrahydropalmatine in the rat.

    abstract::Levo-tetrahydropalmatine (l-THP) has shown significant promise in preclinical and clinical studies to treat drug addiction. Pharmacological MRI methods can elucidate the regional cerebral effects of l-THP, but there are potential confounds from the use of general anesthesia. To investigate the possible anesthetic-drug...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23243

    authors: Liu X,Li R,Yang Z,Hudetz AG,Li SJ

    更新日期:2012-08-01 00:00:00

  • Efficient visualization of vascular territories in the human brain by cycled arterial spin labeling MRI.

    abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20998

    authors: Günther M

    更新日期:2006-09-01 00:00:00

  • Mechanics and imaging of the macrocirculation.

    abstract::The mechanics of the macrocirculation are examined as a basis for imaging blood flow within the system. The macrocirculation is defined as that part of the circulation in which inertial forces are not negligible compared to viscous forces and as such in human subjects comprises the heart and large blood vessels. Becau...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140204

    authors: Caro CG,Parker KH

    更新日期:1990-05-01 00:00:00

  • Robust fully automated shimming of the human brain for high-field 1H spectroscopic imaging.

    abstract::Although a variety of methods have been proposed to provide automated adjustment of shim homogeneity, these methods typically fail or require large numbers of iterations in vivo when applied to regions with poor homogeneity, such as the temporal lobe. These limitations are largely due to 1) the limited accuracy of sin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20941

    authors: Hetherington HP,Chu WJ,Gonen O,Pan JW

    更新日期:2006-07-01 00:00:00

  • Influence of noise correlation in multiple-coil statistical models with sum of squares reconstruction.

    abstract::Noise in the composite magnitude signal from multiple-coil systems is usually assumed to follow a noncentral χ distribution when sum of squares is used to combine images sensed at different coils. However, this is true only if the variance of noise is the same for all coils, and no correlation exists between them. We ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23020

    authors: Aja-Fernández S,Tristán-Vega A

    更新日期:2012-02-01 00:00:00

  • Cardiac transfer function relating energy metabolism to workload in different species as studied with 31P NMR.

    abstract::Cardiac metabolism was studied with 31P NMR in 7 dogs and 4 cats to determine whether animals adapted for different life-styles (stalk and sprint vs endurance running) respond to increased work loads (heart rate X blood pressure product) with different high-energy phosphate kinetics. Hearts were exposed via a left lat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040203

    authors: Ligeti L,Osbakken MD,Clark BJ,Schnall M,Bolinger L,Subramanian H,Leigh JS,Chance B

    更新日期:1987-02-01 00:00:00

  • Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients.

    abstract::The purpose of this study was to determine the value of a blood-pool contrast media (NC100150, Nycomed Imaging (now Amersham Health) Oslo, Norway) for evaluation of venous thrombosis of the deep veins of the pelvis and lower extremities. Twelve patients were prospectively evaluated with conventional X-ray venography (...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10607

    authors: Aschauer M,Deutschmann HA,Stollberger R,Hausegger KA,Obernosterer A,Schöllnast H,Ebner F

    更新日期:2003-11-01 00:00:00

  • Results for diffusion-weighted imaging with a fourth-channel gradient insert.

    abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22971

    authors: Feldman RE,Scholl TJ,Alford JK,Handler WB,Harris CT,Chronik BA

    更新日期:2011-12-01 00:00:00

  • Image reconstruction using a gradient impulse response model for trajectory prediction.

    abstract:PURPOSE:Gradient imperfections remain a challenge in MRI, especially for sequences relying on long imaging readouts. This work aims to explore image reconstruction based on k-space trajectories predicted by an impulse response model of the gradient system. THEORY AND METHODS:Gradient characterization was performed twi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25841

    authors: Vannesjo SJ,Graedel NN,Kasper L,Gross S,Busch J,Haeberlin M,Barmet C,Pruessmann KP

    更新日期:2016-07-01 00:00:00

  • AZTEK: Adaptive zero TE k-space trajectories.

    abstract:PURPOSE:Because of short signal lifetimes and respiratory motion, 3D lung MRI is still challenging today. Zero-TE (ZTE) pulse sequences offer promising solutions as they overcome the issue of short T 2 ∗ ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28483

    authors: Boucneau T,Fernandez B,Besson FL,Menini A,Wiesinger F,Durand E,Caramella C,Darrasse L,Maître X

    更新日期:2021-02-01 00:00:00

  • Inverse reconstruction method for segmented multishot diffusion-weighted MRI with multiple coils.

    abstract::Each k-space segment in multishot diffusion-weighted MRI is affected by a different spatially varying phase which is caused by unavoidable motions and amplified by the diffusion-encoding gradients. A proper image reconstruction therefore requires phase maps for each segment. Such maps are commonly derived from two-dim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22126

    authors: Uecker M,Karaus A,Frahm J

    更新日期:2009-11-01 00:00:00

  • fMRI of auditory stimulation with intermolecular double-quantum coherences (iDQCs) at 1.5T.

    abstract::An intermolecular double-quantum coherence (iDQC) imaging technique was used to study auditory activation in the human brain at 1.5T with a dual temporal lobe surface phased array coil and a quadrature head coil. Preliminary results demonstrate that it is feasible to obtain auditory activation maps using iDQC imaging ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<356::aid-mrm1046>3.0

    authors: Zhong J,Kwok E,Chen Z

    更新日期:2001-03-01 00:00:00

  • Diffusion/perfusion MR imaging of acute cerebral ischemia.

    abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190220

    authors: Kucharczyk J,Mintorovitch J,Asgari HS,Moseley M

    更新日期:1991-06-01 00:00:00

  • Quantifying tissue damage due to focused ultrasound heating observed by MRI.

    abstract::Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<321::aid-mrm16

    authors: Graham SJ,Chen L,Leitch M,Peters RD,Bronskill MJ,Foster FS,Henkelman RM,Plewes DB

    更新日期:1999-02-01 00:00:00

  • Conventions and nomenclature for double diffusion encoding NMR and MRI.

    abstract::Stejskal and Tanner's ingenious pulsed field gradient design from 1965 has made diffusion NMR and MRI the mainstay of most studies seeking to resolve microstructural information in porous systems in general and biological systems in particular. Methods extending beyond Stejskal and Tanner's design, such as double diff...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.25901

    authors: Shemesh N,Jespersen SN,Alexander DC,Cohen Y,Drobnjak I,Dyrby TB,Finsterbusch J,Koch MA,Kuder T,Laun F,Lawrenz M,Lundell H,Mitra PP,Nilsson M,Özarslan E,Topgaard D,Westin CF

    更新日期:2016-01-01 00:00:00

  • In vivo waveguide elastography: effects of neurodegeneration in patients with amyotrophic lateral sclerosis.

    abstract:PURPOSE:Waveguide elastography (WGE) combines magnetic resonance elastography (MRE), diffusion tensor imaging (DTI), and anisotropic inversions for a determination of the elastic properties of white matter. Previously, the method evaluated the anisotropic elastic properties of the corticospinal tracts (CSTs) of healthy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25067

    authors: Romano A,Guo J,Prokscha T,Meyer T,Hirsch S,Braun J,Sack I,Scheel M

    更新日期:2014-12-01 00:00:00

  • Parallel excitation for B-field insensitive fat-saturation preparation.

    abstract::Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B(0) homogeneity have on fat-saturation preparation through the use of the frequency, phase, and amplitude degrees ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23238

    authors: Heilman JA,Derakhshan JD,Riffe MJ,Gudino N,Tkach J,Flask CA,Duerk JL,Griswold MA

    更新日期:2012-08-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    abstract::The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22189

    authors: Tieng QM,Vegh V,Brereton IM

    更新日期:2010-01-01 00:00:00

  • Real-time magnetic resonance imaging of laser heat deposition in tissue.

    abstract::We applied diffusion-sensitive echo planar (Instascan) imaging to study thermal changes caused by a Nd:YAG laser. Images of phantom materials and normal rabbit brain tissue in vivo, acquired in 150 ms, every 2s, clearly showed the dynamics of temperature-related signal intensity changes in the regions irradiated by th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210116

    authors: Bleier AR,Jolesz FA,Cohen MS,Weisskoff RM,Dalcanton JJ,Higuchi N,Feinberg DA,Rosen BR,McKinstry RC,Hushek SG

    更新日期:1991-09-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

    abstract::Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify and improve hemodynamic asse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22090

    authors: Uribe S,Beerbaum P,Sørensen TS,Rasmusson A,Razavi R,Schaeffter T

    更新日期:2009-10-01 00:00:00

  • A Transfer-Learning Approach for Accelerated MRI Using Deep Neural Networks.

    abstract:PURPOSE:Neural networks have received recent interest for reconstruction of undersampled MR acquisitions. Ideally, network performance should be optimized by drawing the training and testing data from the same domain. In practice, however, large datasets comprising hundreds of subjects scanned under a common protocol a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28148

    authors: Dar SUH,Özbey M,Çatlı AB,Çukur T

    更新日期:2020-08-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00