Diffusion/perfusion MR imaging of acute cerebral ischemia.

Abstract:

:In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion, ADC was significantly lower in tissues within the vascular territory of the occluded MCA than in normally perfused tissues in the contralateral hemisphere. Sequential echo-planar imaging was then used in conjunction with bolus injections of the magnetic susceptibility contrast agent, dysprosium DTPA-BMA, to characterize the underlying cerebrovascular perfusion deficits. Normally perfused regions of brain were identified by a dose-dependent 35-70% loss of signal intensity within 6-8 s of contrast administration, whereas ischemic regions appeared relatively hyperintense. These data indicate that sequential diffusion/perfusion imaging may be useful in differentiating permanently damaged from reversibly ischemic brain tissue.

journal_name

Magn Reson Med

authors

Kucharczyk J,Mintorovitch J,Asgari HS,Moseley M

doi

10.1002/mrm.1910190220

subject

Has Abstract

pub_date

1991-06-01 00:00:00

pages

311-5

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

19

pub_type

杂志文章
  • A flexible fast spin echo triple-echo Dixon technique.

    abstract:PURPOSE:To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS:An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26186

    authors: Son JB,Hwang KP,Madewell JE,Bayram E,Hazle JD,Low RN,Ma J

    更新日期:2017-03-01 00:00:00

  • Cardiac tagging with breath-hold cine MRI.

    abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280214

    authors: McVeigh ER,Atalar E

    更新日期:1992-12-01 00:00:00

  • Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

    abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25147

    authors: Cooley CZ,Stockmann JP,Armstrong BD,Sarracanie M,Lev MH,Rosen MS,Wald LL

    更新日期:2015-02-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • In vivo imaging of insulin-secreting human pancreatic ductal cells using MRI reporter gene technique: A feasibility study.

    abstract:PURPOSE:The purpose of this study was to investigate the feasibility of in vivo imaging of human pancreatic ductal cells by OATP1B3 reporter gene under MRI. METHODS:A human cell line (PANC-1) derived from the pancreatic ductal epithelium was used in this study. After transduction of OATP1B3, the cellular physiological...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27749

    authors: Wu MR,Hsiao JK,Liu HM,Huang YY,Tseng YJ,Chou PT,Weng TI,Yang CY

    更新日期:2019-08-01 00:00:00

  • A ranking of diffusion MRI compartment models with in vivo human brain data.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) microstructure imaging provides a unique noninvasive probe into tissue microstructure. The technique relies on biophysically motivated mathematical models, relating microscopic tissue features to the magnetic resonance (MR) signal. This work aims to determine which com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25080

    authors: Ferizi U,Schneider T,Panagiotaki E,Nedjati-Gilani G,Zhang H,Wheeler-Kingshott CA,Alexander DC

    更新日期:2014-12-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

    abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>

    authors: Afeworki M,van Dam GM,Devasahayam N,Murugesan R,Cook J,Coffin D,Larsen JH,Mitchell JB,Subramanian S,Krishna MC

    更新日期:2000-03-01 00:00:00

  • Cationized ferritin as a magnetic resonance imaging probe to detect microstructural changes in a rat model of non-alcoholic steatohepatitis.

    abstract:PURPOSE:The goal of this work was to detect disease-related microstructural changes to the liver using magnetic resonance imaging. Chronic liver disease can cause microstructural changes in the liver that reduce plasma access to the perisinusoidal space--the site of exchange between the blood plasma and the hepatic par...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24619

    authors: Beeman SC,Mandarino LJ,Georges JF,Bennett KM

    更新日期:2013-12-01 00:00:00

  • A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

    abstract:PURPOSE:This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS:The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28425

    authors: Del Bosque R,Cui J,Ogier S,Cheshkov S,Dimitrov IE,Malloy C,Wright SM,McDougall M

    更新日期:2021-01-01 00:00:00

  • Measurement of perfusion and permeability from dynamic contrast-enhanced MRI in normal and pathological vertebral bone marrow.

    abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22415

    authors: Biffar A,Sourbron S,Schmidt G,Ingrisch M,Dietrich O,Reiser MF,Baur-Melnyk A

    更新日期:2010-07-01 00:00:00

  • 31P RINEPT MRSI and VBM reveal alterations in brain aging associated with major depression.

    abstract:PURPOSE:Phosphomono- and diesters, the major components of the choline peak in (1) H magnetic resonance spectroscopy, are associated with membrane anabolic and catabolic mechanisms. With the refocused insensitive nuclei-enhanced polarization transfer technique, these phospholipids are edited and enhanced in the (31) P ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25278

    authors: Biedermann SV,Weber-Fahr W,Demirakca T,Tunc-Skarka N,Hoerst M,Henn F,Sartorius A,Ende G

    更新日期:2015-04-01 00:00:00

  • A strictly noninvasive MR setup dedicated to longitudinal studies of mechanical performance, bioenergetics, anatomy, and muscle recruitment in contracting mouse skeletal muscle.

    abstract::MR techniques have proven their ability to investigate skeletal muscle function in situ. Their benefit in terms of noninvasiveness is, however, lost in animal research, given that muscle stimulation and force output measurements are usually achieved using invasive surgical procedures, thereby excluding repeated invest...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22386

    authors: Giannesini B,Vilmen C,Le Fur Y,Dalmasso C,Cozzone PJ,Bendahan D

    更新日期:2010-07-01 00:00:00

  • Projection reconstruction MR imaging using FOCUSS.

    abstract::The focal underdetermined system solver (FOCUSS) was originally designed to obtain sparse solutions by successively solving quadratic optimization problems. This article adapts FOCUSS for a projection reconstruction MR imaging problem to obtain high resolution reconstructions from angular under-sampled radial k-space ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21202

    authors: Ye JC,Tak S,Han Y,Park HW

    更新日期:2007-04-01 00:00:00

  • Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

    abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22809

    authors: Fluckiger JU,Schabel MC,DiBella EV

    更新日期:2011-08-01 00:00:00

  • Restricted field of view magnetic resonance imaging of a dynamic time series.

    abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21115

    authors: Pisani L,Bammer R,Glover G

    更新日期:2007-02-01 00:00:00

  • Pattern recognition of MRSI data shows regions of glioma growth that agree with DTI markers of brain tumor infiltration.

    abstract::Gliomas are the most common primary brain tumors and the majority are highly malignant, with one of the worst prognoses for patients. Gliomas are characterized by invasive growth into normal brain tissue that makes complete surgical resection and accurate radiotherapy planning extremely difficult. We have performed in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22163

    authors: Wright AJ,Fellows G,Byrnes TJ,Opstad KS,McIntyre DJ,Griffiths JR,Bell BA,Clark CA,Barrick TR,Howe FA

    更新日期:2009-12-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • Does fractional anisotropy have better noise immunity characteristics than relative anisotropy in diffusion tensor MRI? An analytical approach.

    abstract::Fractional anisotropy (FA) and relative anisotropy (RA) are the two most commonly used scalar measures of anisotropy in diffusion tensor (DT) MRI. While a few published studies have shown that FA has superior noise immunity relative to RA, no theoretical basis has been proposed to explain this behavior. In the current...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10682

    authors: Hasan KM,Alexander AL,Narayana PA

    更新日期:2004-02-01 00:00:00

  • Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

    abstract:PURPOSE:Cardiac stimulation (CS) limits to gradient coil switching speed are difficult to measure in humans; instead, current regulatory guidelines (IEC 60601-2-33) are based on animal experiments and electric field-to-dB/dt conversion factors computed for a simple, homogeneous body model. We propose improvement to thi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28472

    authors: Klein V,Davids M,Schad LR,Wald LL,Guérin B

    更新日期:2021-02-01 00:00:00

  • Correlation of spectroscopy and magnetization transfer imaging in the evaluation of demyelinating lesions and normal appearing white matter in multiple sclerosis.

    abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320303

    authors: Hiehle JF Jr,Lenkinski RE,Grossman RI,Dousset V,Ramer KN,Schnall MD,Cohen JA,Gonzalez-Scarano F

    更新日期:1994-09-01 00:00:00

  • MRI assessment of coronary microvascular endothelial nitric oxide synthase function using myocardial T1 mapping.

    abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26870

    authors: Cui SX,Epstein FH

    更新日期:2018-04-01 00:00:00

  • Correction for partial volume errors in MR heart perfusion imaging.

    abstract::Myocardial MR first-pass perfusion time courses are contaminated by signals from the ventricles (spillover) as a consequence of partial volume effects and motion. An early increase in the signal intensity from the myocardium is an indicator of contamination. This contamination leads to under- or overestimation of perf...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20015

    authors: Köstler H,Ritter C,Reiss-Zimmermann M,Beer M,Hahn D,Sandstede J

    更新日期:2004-04-01 00:00:00

  • Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH.

    abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360402

    authors: Hatabu H,Gaa J,Kim D,Li W,Prasad PV,Edelman RR

    更新日期:1996-10-01 00:00:00

  • Motion corrected water/fat whole-heart coronary MR angiography with 100% respiratory efficiency.

    abstract:PURPOSE:To develop a framework for respiratory motion-corrected 3D whole-heart water/fat coronary MR angiography (CMRA) at 3T with reduced and predictable scan time. METHODS:A 3D dual-echo acquisition and respiratory motion-corrected reconstruction framework for water/fat CMRA imaging was developed. The acquisition se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27732

    authors: Munoz C,Cruz G,Neji R,Botnar RM,Prieto C

    更新日期:2019-08-01 00:00:00

  • Training a neural network for Gibbs and noise removal in diffusion MRI.

    abstract:PURPOSE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28395

    authors: Muckley MJ,Ades-Aron B,Papaioannou A,Lemberskiy G,Solomon E,Lui YW,Sodickson DK,Fieremans E,Novikov DS,Knoll F

    更新日期:2021-01-01 00:00:00

  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • Phase-labeled reference EPI for frequency-segmented inhomogeneity corrections (PREFICS).

    abstract:PURPOSE:To develop a method to correct for geometric distortions in non-Cartesian echo planar imaging using data acquired in a fast prescan. METHODS:Echo planar images were obtained using a non-Cartesian density weighted k-space trajectory. In contrast to linear Cartesian acquisition, distortions arising in non-Cartes...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24737

    authors: Zeller M,Müller A,Hahn D,Köstler H

    更新日期:2014-03-01 00:00:00

  • Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing.

    abstract:PURPOSE:Dynamic phosphorus MR spectroscopic imaging (31 P-MRSI) experiments require temporal resolution on the order of seconds to concurrently assess different muscle groups. A highly accelerated pulse sequence combining flyback echo-planar spectroscopic imaging (EPSI) and compressed sensing was developed and tested i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27682

    authors: Santos-Díaz A,Harasym D,Noseworthy MD

    更新日期:2019-06-01 00:00:00