Abstract:
:A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume for a dynamic series, an outer volume suppression (OVS) preparation that saturates signal external to a cylinder through the subject is followed by slice-selective excitation and a spiral readout. The pass- and stopband efficiencies of the OVS in an agar gel phantom were 97% (+/-1.5%) and 3% (+/-1%), respectively. Profiles of the temporal signal-to-noise ratio (SNR) were measured in a phantom and an adult brain. The rFOV sequence reduced distortions from off-resonance signal and T2*-induced blurring compared to a conventional sequence. Sequence utility is demonstrated for high-resolution rFOV functional MRI (fMRI) in the visual cortex. The rFOV sequence may prove to be useful for other multislice dynamic and high-resolution imaging applications.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Pisani L,Bammer R,Glover Gdoi
10.1002/mrm.21115subject
Has Abstractpub_date
2007-02-01 00:00:00pages
297-307issue
2eissn
0740-3194issn
1522-2594journal_volume
57pub_type
杂志文章abstract::In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20108
更新日期:2004-07-01 00:00:00
abstract::Paramagnetic ions complexed to proteins may lose, retain, or enhance solvent paramagnetic relaxation (SPR) relative to free solution. We measured T1 and T2 of three mouse cancers, their normal counterparts, and six additional tissues. Long T1 of cancers was not caused by necrosis or by different contents of water, fat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910180204
更新日期:1991-04-01 00:00:00
abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22037
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25196
更新日期:2014-05-01 00:00:00
abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370603
更新日期:1997-06-01 00:00:00
abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060102
更新日期:1988-01-01 00:00:00
abstract:PURPOSE:To improve multichannel compressed sensing (CS) reconstruction for MR proton resonance frequency (PRF) shift thermography, with application to MRI-induced RF heating evaluation and MR guided high intensity focused ultrasound (MRgFUS) temperature monitoring. METHODS:A new compressed sensing reconstruction is pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27666
更新日期:2019-06-01 00:00:00
abstract::Genetically engineered mouse models provide enormous potential for investigation of the underlying mechanisms of atherosclerotic disease, but noninvasive imaging methods for analysis of atherosclerosis in mice are currently limited. This study aimed to demonstrate the feasibility of MRI to noninvasively visualize athe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10500
更新日期:2003-07-01 00:00:00
abstract::Chemical shift-based multipoint water-fat separation methods have been applied in balanced steady-state free precession (bSSFP) sequences because of the high signal-to-noise-ratio (SNR) attainable. In this approach the echo formation is approximated to occur concurrently for both water and fat at an echo time (TE) equ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21303
更新日期:2007-08-01 00:00:00
abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21079
更新日期:2006-12-01 00:00:00
abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24129
更新日期:2012-11-01 00:00:00
abstract::In order to obtain proton magnetic resonance spectra from the normal human kidney in vivo, we employed a STEAM sequence with delay times TE = 10 ms and TM = 30 ms. Signals are attenuated during STEAM sequences by J-coupling effects and by macroscopic movement of the sample. The combination of short echo times and resp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910310503
更新日期:1994-05-01 00:00:00
abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910340111
更新日期:1995-07-01 00:00:00
abstract:PURPOSE:A direct method of imaging neural activity was simulated to determine typical signal sizes. METHODS:An active bidomain finite-element model was used to estimate approximate perturbations in MR phase data as a result of neural tissue activity, and when an external MR electrical impedance tomography imaging curr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27351
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24824
更新日期:2014-05-01 00:00:00
abstract::A cerebrospinal fluid (CSF)-suppressed flow-attenuated inversion recovery (FLAIR) double-shot diffusion echo-planar imaging (EPI) sequence was developed and used, along with a non-CSF-suppressed version of the sequence, to determine the extent of the contribution of CSF partial-volume averaging to the apparent diffusi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370117
更新日期:1997-01-01 00:00:00
abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20714
更新日期:2005-12-01 00:00:00
abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330123
更新日期:1995-01-01 00:00:00
abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21074
更新日期:2006-12-01 00:00:00
abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19
更新日期:1999-07-01 00:00:00
abstract::At high magnetic fields the performance of a volume-type body coil inside a human sized MR-scanner is influenced by the waveguide action of the scanner's bore. This can result in undesirable strong radio frequency fields B1+) outside the coil's target volume. A radio frequency (RF) transmit system, exploiting this wav...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24496
更新日期:2013-09-01 00:00:00
abstract::Magnetic resonance (MR) can offer a unique window on the structure/function relationships in the brain, by utilizing the established link between tissue function, metabolism, and hemodynamics. This report focuses on recent applications of MR-based cerebral blood volume (CBV) imaging in humans. Our methodology uses hig...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910220227
更新日期:1991-12-01 00:00:00
abstract::In rapidly acquired gradient echo images, lipid regions usually appear as areas of high signal intensity. In 2D inflow angiograms processed by the maximum intensity projection algorithm, this high lipid signal may prevent angiographic visualization of some blood vessels. We present a new approach to suppress the lipid...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910210110
更新日期:1991-09-01 00:00:00
abstract:PURPOSE:To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS:A metric based on patient-specifi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25366
更新日期:2015-06-01 00:00:00
abstract::The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surface...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360213
更新日期:1996-08-01 00:00:00
abstract::The accuracy of the outcome in a diffusion tensor imaging (DTI) experiment depends on the acquisition scheme as well as the postprocessing methods used. In the present study, the DTI results acquired after applying different combinations of diffusion-weighted (DW) gradient orientations were initially compared. Then, s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10046
更新日期:2002-02-01 00:00:00
abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26824
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:Magnetic resonance imaging (MRI)-based techniques for assessing liver iron concentration (LIC) have been limited by single scanner calibration against biopsy. Here, the calibration of spin-density projection-assisted (SDPA) R2-MRI (FerriScan®) in iron-overloaded β-thalassemia patients treated with the iron chel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,多中心研究
doi:10.1002/mrm.24854
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS:3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise pe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24570
更新日期:2013-11-01 00:00:00