Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM).

Abstract:

:The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surfaces (3D MR-CCM) has been developed for cartilage thickness measurements. Eight cadaveric knee-joint specimens and six volunteers were imaged using a fat-suppressed gradient-echo sequence at a resolution of 2 x 0.31 x 0.31 mm3. Cartilage volumes and topographical thickness maps were obtained and compared with those derived from anatomical sections by image analysis. The deviation of the MR volumes from those of the sections was 1-12%, the coefficient of variation after repositioning ranged from 2.9% (patella) to 8.2% (lateral tibial plateau). Between 60% and 80% of all image points could be attributed to identical thickness intervals, less than 20% deviating by more than 0.5 mm. The intraobserver and interobserver reproducibilities were very high in both the specimens and the volunteers. In the knee joint, 3D reconstructions of the cartilages, and measurements that take into account the out-of-plane deviation of the interface normals (3D MR-CCM), are required.

journal_name

Magn Reson Med

authors

Eckstein F,Gavazzeni A,Sittek H,Haubner M,Lösch A,Milz S,Englmeier KH,Schulte E,Putz R,Reiser M

doi

10.1002/mrm.1910360213

subject

Has Abstract

pub_date

1996-08-01 00:00:00

pages

256-65

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

36

pub_type

杂志文章
  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

    abstract:PURPOSE:A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements. THEORY AND METHODS:An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28068

    authors: Cao Z,Yan X,Gore JC,Grissom WA

    更新日期:2020-06-01 00:00:00

  • B1AC-MAMBA: B1 array combined with multiple-acquisition micro B0 array parallel magnetic resonance imaging.

    abstract::The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10464

    authors: Paley MN,Lee KJ,Wild JM,Fichele S,Whitby EH,Wilkinson ID,Van Beek EJ,Griffiths PD

    更新日期:2003-06-01 00:00:00

  • Pulsatile flow artifacts in 3D magnetic resonance imaging.

    abstract::Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300305

    authors: Frank LR,Buxton RB,Kerber CW

    更新日期:1993-09-01 00:00:00

  • Perfusion imaging using dynamic arterial spin labeling (DASL).

    abstract::Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of the tissue, and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1136

    authors: Barbier EL,Silva AC,Kim SG,Koretsky AP

    更新日期:2001-06-01 00:00:00

  • In vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2.

    abstract::Follow-up T(1)-weighted 3D gradient-echo MRI (2.35 T) of murine brain in vivo (N = 5) at 120 microm isotropic resolution revealed spatially distinct signal increases 6-48 hr after subcutaneous application of MnCl(2) (20 mg/kg). The effects result from a shortening of the water proton T(1) relaxation time due to the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10276

    authors: Watanabe T,Natt O,Boretius S,Frahm J,Michaelis T

    更新日期:2002-11-01 00:00:00

  • Transmurally differentiated measurement of ATP hydrolysis rates in the in vivo porcine hearts.

    abstract:PURPOSE:Compare the transmural distribution of forward creatine kinase reaction (kf,CK ) and ATP hydrolysis rate (kr,ATPase ) in the myocardium of normal porcine heart. Rate constants were extracted from partially relaxed spectra by applying the T1nom method, effectively reducing data acquisition time by up to an order...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26162

    authors: Jang A,Xiong Q,Zhang P,Zhang J

    更新日期:2016-05-01 00:00:00

  • Relative indices of water diffusion anisotropy are equivalent in live and formalin-fixed mouse brains.

    abstract::Formalin fixation of tissue is a common laboratory practice. A direct comparison of diffusion tensor imaging (DTI) parameters from mouse brains before (in vivo) and after (ex vivo) formalin fixation is reported herein. Five diffusion indices were examined in a cohort of seven mice: relative anisotropy (RA), directiona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10605

    authors: Sun SW,Neil JJ,Song SK

    更新日期:2003-10-01 00:00:00

  • Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He.

    abstract::Images of hyperpolarized 3He were acquired during breath-hold in four healthy volunteers with the use of an optimized 3D gradient-echo sequence. The images were compared with existing 2D gradient-echo methods. The average SNR from a 13-mm-thick slice in the peripheral lung was 1.4 times greater with 3D. In the airways...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20164

    authors: Wild JM,Woodhouse N,Paley MN,Fichele S,Said Z,Kasuboski L,van Beek EJ

    更新日期:2004-09-01 00:00:00

  • 3D-multi-spectral T2 mapping near metal implants.

    abstract:PURPOSE:Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27744

    authors: Bhave S,Koff MF,Sivaram Kaushik S,Potter HG,Koch KM

    更新日期:2019-08-01 00:00:00

  • Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

    abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22234

    authors: Schär M,Vonken EJ,Stuber M

    更新日期:2010-02-01 00:00:00

  • Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24114

    authors: Tam LK,Stockmann JP,Galiana G,Constable RT

    更新日期:2012-10-01 00:00:00

  • Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes.

    abstract::A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10159

    authors: Bodurka J,Bandettini PA

    更新日期:2002-06-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Systematic analysis of the intravoxel incoherent motion threshold separating perfusion and diffusion effects: Proposal of a standardized algorithm.

    abstract:PURPOSE:To systematically evaluate the dependence of intravoxel-incoherent-motion (IVIM) parameters on the b-value threshold separating the perfusion and diffusion compartment, and to implement and test an algorithm for the standardized computation of this threshold. METHODS:Diffusion weighted images of the upper abdo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25506

    authors: Wurnig MC,Donati OF,Ulbrich E,Filli L,Kenkel D,Thoeny HC,Boss A

    更新日期:2015-11-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

    abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3

    authors: de Zwart JA,Vimeux FC,Delalande C,Canioni P,Moonen CT

    更新日期:1999-07-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies.

    abstract::MRI of myocardial perfusion observed with an extracellular contrast agent has proven valuable for the detection of coronary artery disease. During contrast enhancement transient dark rim artifacts are sometimes visible, complicating diagnosis and quantification. In this work a quantification of the frequency offsets c...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.21723

    authors: Ferreira P,Gatehouse P,Bucciarelli-Ducci C,Wage R,Firmin D

    更新日期:2008-10-01 00:00:00

  • Phase contrast MRI with flow compensation view sharing.

    abstract:PURPOSE:To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS:PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25133

    authors: Wang D,Shao J,Rapacchi S,Middione MJ,Ennis DB,Hu P

    更新日期:2015-02-01 00:00:00

  • An analytical solution for the SSFP signal in MRI.

    abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10410

    authors: Hänicke W,Vogel HU

    更新日期:2003-04-01 00:00:00

  • MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis.

    abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1252

    authors: Pathak AP,Schmainda KM,Ward BD,Linderman JR,Rebro KJ,Greene AS

    更新日期:2001-10-01 00:00:00

  • Magnitude image CSPAMM reconstruction (MICSR).

    abstract::Image reconstruction of tagged cardiac MR images using complementary spatial modulation of magnetization (CSPAMM) requires the subtraction of two complex datasets to remove the untagged signal. Although the resultant images typically have sharper and more persistent tags than images formed without complementary taggin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10523

    authors: NessAiver M,Prince JL

    更新日期:2003-08-01 00:00:00

  • Quantification of regional blood volumes by rapid T1 mapping.

    abstract::A new method is presented for the quantitative determination of regional blood volumes in vivo. It is based on rapid quantitative T1 mapping by Snapshot FLASH MRI combined with the injection of an intravascular MR contrast agent. Regional blood volumes in four different tissues of the rat (skeletal muscle, heart, live...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290521

    authors: Schwarzbauer C,Syha J,Haase A

    更新日期:1993-05-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Mechanics and imaging of the macrocirculation.

    abstract::The mechanics of the macrocirculation are examined as a basis for imaging blood flow within the system. The macrocirculation is defined as that part of the circulation in which inertial forces are not negligible compared to viscous forces and as such in human subjects comprises the heart and large blood vessels. Becau...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140204

    authors: Caro CG,Parker KH

    更新日期:1990-05-01 00:00:00

  • Ultrashort TE T1rho (UTE T1rho) imaging of the Achilles tendon and meniscus.

    abstract::In this study, we report the use of a novel ultrashort echo time T(1)rhoT(1) sequence that combines a spin-lock preparation pulse with a two-dimensional ultrashort echo time sequence of a nominal echo time 8 microsec. The ultrashort echo time-T(1)rho sequence was employed to quantify T(1)rho in short T(2) tissues incl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22474

    authors: Du J,Carl M,Diaz E,Takahashi A,Han E,Szeverenyi NM,Chung CB,Bydder GM

    更新日期:2010-09-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Strategy for lipid suppression in lactate imaging using STIR-DQCT: a study of hypoxic-ischemic brain injury.

    abstract::In vivo lactate detection using gradient enhanced double quantum coherence transfer (DQCT) was significantly improved by addition of short-time-inversion-recovery (STIR). Phantom studies demonstrated lipid suppression down to the background noise level with 33% loss of lactate signal. In vivo studies using a rabbit mo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400416

    authors: Nakai T,Rhine WD,Okada T,Stevenson DK,Spielman DM

    更新日期:1998-10-01 00:00:00

  • Rapid in vivo musculoskeletal MR with parallel imaging at 7T.

    abstract::The purpose of this work was to implement autocalibrating GRAPPA-based parallel imaging (PI) for in vivo high-resolution (HR) MRI of cartilage and trabecular bone micro-architecture at 7T and to evaluate its performance based on comparison of MR-derived morphology metrics between accelerated and conventional images an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21455

    authors: Banerjee S,Krug R,Carballido-Gamio J,Kelley DA,Xu D,Vigneron DB,Majumdar S

    更新日期:2008-03-01 00:00:00

  • The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla.

    abstract:PURPOSE:Dipole antennas in ultrahigh field MRI have demonstrated advantages over more conventional designs. In this study, the fractionated dipole antenna is presented: a dipole where the legs are split into segments that are interconnected by capacitors or inductors. METHODS:A parameter study has been performed on di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25596

    authors: Raaijmakers AJ,Italiaander M,Voogt IJ,Luijten PR,Hoogduin JM,Klomp DW,van den Berg CA

    更新日期:2016-03-01 00:00:00