A versatile multinuclear probe designed for in vivo NMR spectroscopy: applications to subcutaneous human tumors in mice.

Abstract:

:We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoidal coil designs are described and applied to observe 31P, 13C, and 1H natural abundance spectra of subcutaneously implanted human tumors in mice. For 31P and 31C observation with 1H decoupling, a concentric coil arrangement was employed with a broadband inner coil and the outer coil tuned to 1H at 400 MHz. A single coil tuned to 400 MHz was used to observe 1H resonances. A thin copper foil design was found to be superior with respect to S/N and resolution to previously described Faraday shields used to shield the NMR signals originating from nontumor tissues. 31P spectra of in vivo tumor tissue were compared to spectra of in vitro perfused tumor cells of the same origin. Tumor tissue in vivo exhibited much higher levels of inorganic phosphate and phosphocreatine. Signals from [13C2]glucose and its major metabolite, [13C2]lactate, were readily observed and monitored in an unobstructed region of the 13C spectra of tumor tissue in vivo following the injection of [13C2]glucose in adjacent tissues. A 1H spectrum of tumor tissue, characterized by five broad resonances, was observed with excellent water suppression.

journal_name

Magn Reson Med

authors

Lyon RC,Tschudin RG,Daly PF,Cohen JS

doi

10.1002/mrm.1910060102

subject

Has Abstract

pub_date

1988-01-01 00:00:00

pages

1-14

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

6

pub_type

杂志文章
  • Assessment of exposure to MRI motion-induced fields based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.

    abstract:PURPOSE:The goal of this study was to conduct an exposure assessment for workers moving through the stray stationary field of common MRI scanners, performed according to the recent International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines, which aim at avoiding annoying sensory effects. THEORY ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26031

    authors: Zilberti L,Bottauscio O,Chiampi M

    更新日期:2016-10-01 00:00:00

  • Projection reconstruction MR imaging using FOCUSS.

    abstract::The focal underdetermined system solver (FOCUSS) was originally designed to obtain sparse solutions by successively solving quadratic optimization problems. This article adapts FOCUSS for a projection reconstruction MR imaging problem to obtain high resolution reconstructions from angular under-sampled radial k-space ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21202

    authors: Ye JC,Tak S,Han Y,Park HW

    更新日期:2007-04-01 00:00:00

  • DeepCEST: 9.4 T Chemical exchange saturation transfer MRI contrast predicted from 3 T data - a proof of concept study.

    abstract:PURPOSE:To determine the feasibility of employing the prior knowledge of well-separated chemical exchange saturation transfer (CEST) signals in the 9.4 T Z-spectrum to separate overlapping CEST signals acquired at 3 T, using a deep learning approach trained with 3 T and 9.4 T CEST spectral data from brains of the same ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27690

    authors: Zaiss M,Deshmane A,Schuppert M,Herz K,Glang F,Ehses P,Lindig T,Bender B,Ernemann U,Scheffler K

    更新日期:2019-06-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • New double quantum coherence filter for localized detection of glutathione in vivo.

    abstract::In this work, a new double quantum filter for glutathione (GSH) editing is introduced, combined with the point-resolved spectroscopy localization sequence (PRESS), and demonstrated in vivo. Compared to the conventional double quantum coherence filter, the new filter has two major advantages. First, it eliminates the n...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20788

    authors: Zhao T,Heberlein K,Jonas C,Jones DP,Hu X

    更新日期:2006-03-01 00:00:00

  • Proton exchange rates from amino acid side chains--implications for image contrast.

    abstract::The proton exchange rates between water and the hydroxyl protons of threonine, serine, tyrosine, the amino protons of lysine, and the guanidinium protons of arginine were measured in the pH range 0.5 to 8.5 and for the temperatures 4 degrees C, 10 degrees C, 20 degrees C, 30 degrees C, and 36 degrees C. The intrinsic ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350106

    authors: Liepinsh E,Otting G

    更新日期:1996-01-01 00:00:00

  • Effects of anesthesia on renal function and metabolism in rats assessed by hyperpolarized MRI.

    abstract:PURPOSE:Anesthesia is necessary for most animal studies requiring invasive procedures. It is well documented that various types of anesthesia modulate a wide variety of important metabolic and functional processes in the body, and as such, represent a potential limitation in the study design. In the present study, we a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27165

    authors: Qi H,Mariager CØ,Lindhardt J,Nielsen PM,Stødkilde-Jørgensen H,Laustsen C

    更新日期:2018-11-01 00:00:00

  • Rapid six-degree-of-freedom motion detection using prerotated baseline spherical navigator echoes.

    abstract::A new spherical navigator echo (SNAV) registration technique is presented. This technique starts by collecting a set of SNAV templates at a reference position. These templates are acquired by rotating the gradient system to result in rotation angles that uniformly cover a predefined range of rotation. The rotation ang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22629

    authors: Liu J,Drangova M

    更新日期:2011-02-01 00:00:00

  • Phase-labeled reference EPI for frequency-segmented inhomogeneity corrections (PREFICS).

    abstract:PURPOSE:To develop a method to correct for geometric distortions in non-Cartesian echo planar imaging using data acquired in a fast prescan. METHODS:Echo planar images were obtained using a non-Cartesian density weighted k-space trajectory. In contrast to linear Cartesian acquisition, distortions arising in non-Cartes...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24737

    authors: Zeller M,Müller A,Hahn D,Köstler H

    更新日期:2014-03-01 00:00:00

  • Effect of distortion corrections on the tractography quality in spinal cord diffusion-weighted imaging.

    abstract:PURPOSE:To assess the impact of a different distortion correction (DC) method and patient geometry (sagittal balance) on the quality of spinal cord tractography rendering according to different tractography approaches. METHODS:Forty-four adults free of spinal cord diseases underwent cervical diffusion-weighted imaging...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28665

    authors: Dauleac C,Bannier E,Cotton F,Frindel C

    更新日期:2021-01-21 00:00:00

  • Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

    abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21157

    authors: Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

    更新日期:2007-03-01 00:00:00

  • Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

    abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25147

    authors: Cooley CZ,Stockmann JP,Armstrong BD,Sarracanie M,Lev MH,Rosen MS,Wald LL

    更新日期:2015-02-01 00:00:00

  • Magnetic field dependence of proton relaxation rates in tissue with added Mn2+: rabbit liver and kidney.

    abstract::Since contrast in magnetic resonance imaging (MRI) is so sensitive to the magnetic relaxation rates of tissue protons, the use of paramagnetic ions to alter contrast in a tissue-specific fashion is an alluring prospect. The influence of these ions on the proton relaxation rates in homogeneous solutions is known to var...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020206

    authors: Koenig SH,Brown RD 3rd,Goldstein EJ,Burnett KR,Wolf GL

    更新日期:1985-04-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging.

    abstract::Amide proton transfer imaging, a specific form of chemical exchange saturation transfer imaging, has previously been applied to studies of acute ischemic acidosis, stroke, and cancer. However, interpreting the resulting contrast is complicated by its dependence on the exchange rate between amides and water, the amide ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23276

    authors: Zu Z,Janve VA,Li K,Does MD,Gore JC,Gochberg DF

    更新日期:2012-09-01 00:00:00

  • Comparison of prospective head motion correction with NMR field probes and an optical tracking system.

    abstract:PURPOSE:The aim of this study was to compare prospective head motion correction and motion tracking abilities of two tracking systems: Active NMR field probes and a Moiré phase tracking camera system using an optical marker. METHODS:Both tracking systems were used simultaneously on human subjects. The prospective head...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27343

    authors: Eschelbach M,Aghaeifar A,Bause J,Handwerker J,Anders J,Engel EM,Thielscher A,Scheffler K

    更新日期:2019-01-01 00:00:00

  • Combined T2 -preparation and multidimensional outer volume suppression for coronary artery imaging with 3D cones trajectories.

    abstract:PURPOSE:To develop a modular magnetization preparation sequence for combined T2 -preparation and multidimensional outer volume suppression (OVS) for coronary artery imaging. METHODS:A combined T2 -prepared 1D OVS sequence with fat saturation was defined to contain a 90°-60 180°60 composite nonselective tip-down pulse,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28057

    authors: Zeng DY,Baron CA,Malavé MO,Kerr AB,Yang PC,Hu BS,Nishimura DG

    更新日期:2020-06-01 00:00:00

  • In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

    abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22037

    authors: Mitsouras D,Owens CD,Conte MS,Ersoy H,Creager MA,Rybicki FJ,Mulkern RV

    更新日期:2009-09-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • Optimized isotropic diffusion weighting.

    abstract::The authors introduce several sets of time-efficient gradient waveforms for applying isotropic diffusion weighting in NMR experiments. This creates signal attenuation that depends on the trace of the diffusion tensor and is therefore rotationally invariant. Numerical methods for the calculation of such gradient sets a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340202

    authors: Wong EC,Cox RW,Song AW

    更新日期:1995-08-01 00:00:00

  • Intravoxel incoherent motion imaging using steady-state free precession.

    abstract::IVIM MR imaging is a method which generates images of diffusion and perfusion in vivo. Until now, intravoxel incoherent motion (IVIM) images have been obtained using spin-echo sequences with extragradient pulses, resulting in long acquisition times (typically 2 x 8 min 32 s). A new method is proposed here, using stead...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070312

    authors: Le Bihan D

    更新日期:1988-07-01 00:00:00

  • Novel RF coil geometry for lower extremity imaging.

    abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10712

    authors: Brown R,Mareyam A,Reid E,Wang Y

    更新日期:2004-03-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Assessing linear time-invariance in human primary somatosensory cortex with BOLD fMRI using vibrotactile stimuli.

    abstract::The assumption of linear time-invariance (LTI) in the human primary somatosensory cortex (SI) is assessed for fMRI signals generated by variable-duration vibrotactile stimuli. Predictions based on time-shifted summation (TSS) of responses to 2 s stimuli overestimate observed BOLD signal amplitudes in response to longe...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20363

    authors: Nangini C,Macintosh BJ,Tam F,Staines WR,Graham SJ

    更新日期:2005-02-01 00:00:00

  • Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises.

    abstract:PURPOSE:To develop and test real-time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. METHODS:In 15 healthy participants, 6 groups of lower-leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28095

    authors: Schrank F,Warmuth C,Görner S,Meyer T,Tzschätzsch H,Guo J,Uca YO,Elgeti T,Braun J,Sack I

    更新日期:2020-07-01 00:00:00

  • An analytical solution for the SSFP signal in MRI.

    abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10410

    authors: Hänicke W,Vogel HU

    更新日期:2003-04-01 00:00:00

  • Electromagnetic actuator for generating variably oriented shear waves in MR elastography.

    abstract::Magnetic resonance elastography (MRE) is a recently developed technique for determining the mechanical properties of biological tissue. In dynamic MRE, electromagnetic units (actuators) are widely used to generate shear waves in tissue. These actuators exploit the interaction between the static magnetic field B(0) and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10479

    authors: Braun J,Braun K,Sack I

    更新日期:2003-07-01 00:00:00

  • Metabolite 1H relaxation in normal and hyponatremic brain.

    abstract::Proton spin relaxation rate constants in normal and hyponatremic rat brain were measured to determine the sensitivity of metabolite relaxation properties to cytotoxic edema and to quantify metabolite concentration in normal and edematous brain. Relaxation rate constants for protons of water and spectral regions with d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350510

    authors: Rooney WD,Ebisu T,Mancuso A,Graham S,Weiner MW,Maudsley AA

    更新日期:1996-05-01 00:00:00

  • Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

    abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20714

    authors: Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

    更新日期:2005-12-01 00:00:00