Motion corrected water/fat whole-heart coronary MR angiography with 100% respiratory efficiency.

Abstract:

PURPOSE:To develop a framework for respiratory motion-corrected 3D whole-heart water/fat coronary MR angiography (CMRA) at 3T with reduced and predictable scan time. METHODS:A 3D dual-echo acquisition and respiratory motion-corrected reconstruction framework for water/fat CMRA imaging was developed. The acquisition sequence integrates a 2D dual-echo image navigator (iNAV), enabling 100% respiratory scan efficiency. Respiratory motion estimated from both the 2D iNAVs and the 3D data itself is used to produce nonrigid motion-corrected water/fat CMRA images. A first study to investigate which iNAV (water, fat, in-phase or out-of-phase) provides the best translational motion estimation was performed in 10 healthy subjects. Subsequently, nonrigid motion-corrected water/fat images were compared to a diaphragmatic navigator gated and tracked water/fat CMRA acquisition. Image quality metrics included visible vessel length and vessel sharpness for both the left anterior descending and right coronary arteries. RESULTS:Average vessel sharpness achieved with water, fat, in-phase and out-of-phase iNAVs was 33.8%, 29.6%, 32.2%, and 38.5%, respectively. Out-of-phase iNAVs were therefore used for estimating translational respiratory motion for the remainder of the study. No statistically significant differences in vessel length and sharpness (P > 0.01) were observed between the proposed nonrigid motion correction approach and the reference images, although data acquisition was significantly shorter (P < 2.6×10-4 ). Motion correction improved vessel sharpness by 60.4% and vessel length by 47.7%, on average, in water CMRA images in comparison with no motion correction. CONCLUSION:The feasibility of a novel motion-corrected water/fat CMRA approach has been demonstrated at 3T, producing images comparable to a reference gated acquisition, but in a shorter and predictable scan time.

journal_name

Magn Reson Med

authors

Munoz C,Cruz G,Neji R,Botnar RM,Prieto C

doi

10.1002/mrm.27732

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

732-742

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

82

pub_type

杂志文章
  • Inferring multiple maxima in intravoxel white matter fiber distribution.

    abstract::A new methodology is introduced that characterizes the intravoxel orientation distribution function (ODF) based on a single-fiber model of the diffusion MRI signal. Using a Bayesian framework the probability of finding a fiber in a specific orientation is obtained. The proposed ODF estimation relies on a cigar-like di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21673

    authors: Canales-Rodríguez EJ,Melie-García L,Iturria-Medina Y,Martínez-Montes E,Alemán-Gómez Y,Lin CP

    更新日期:2008-09-01 00:00:00

  • Diffusion/perfusion MR imaging of acute cerebral ischemia.

    abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190220

    authors: Kucharczyk J,Mintorovitch J,Asgari HS,Moseley M

    更新日期:1991-06-01 00:00:00

  • Effect of feature extraction for brain tumor classification based on short echo time 1H MR spectra.

    abstract::This study examines the effect of feature extraction methods prior to automated pattern recognition based on magnetic resonance spectroscopy (MRS) for brain tumor diagnosis. Since individual inspection of spectra is time-consuming and requires specific spectroscopic expertise, the introduction of clinical decision sup...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21626

    authors: Luts J,Poullet JB,Garcia-Gomez JM,Heerschap A,Robles M,Suykens JA,Van Huffel S

    更新日期:2008-08-01 00:00:00

  • Noise removal in magnetic resonance diffusion tensor imaging.

    abstract::Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20582

    authors: Chen B,Hsu EW

    更新日期:2005-08-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Fast 31P chemical shift imaging using SSFP methods.

    abstract::Steady-state free precession (SSFP) methods have been very successful due to their high signal and short imaging times. These properties make them good candidates for applications that intrinsically suffer from low signal such as low gamma nuclei imaging. A new chemical shift imaging (CSI) technique based on the SSFP ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10279

    authors: Speck O,Scheffler K,Hennig J

    更新日期:2002-10-01 00:00:00

  • Stereotaxic assembly and procedures for simultaneous electrophysiological and MRI study of conscious rat.

    abstract::A stereotaxic restraining assembly was designed and developed for simultaneous electrophysiological recordings and functional MRI (fMRI) data acquisition from a conscious rat. The design of the nonmagnetic stereotaxic apparatus facilitated the restraining of head and body of the unanesthetized conscious animal during ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10441

    authors: Khubchandani M,Mallick HN,Jagannathan NR,Mohan Kumar V

    更新日期:2003-05-01 00:00:00

  • In vivo MR imaging and spectroscopy using hyperpolarized 129Xe.

    abstract::Hyperpolarized 129Xe has been used to obtain gas phase images of mouse lung in vivo, showing distinct ventilation variation as a function of the breathing cycle. Spectra of 129Xe in the thorax show complex structure in both the gas phase (-4 to 3 ppm) and tissue-dissolved (190-205 ppm) regions. The alveolar gas peak s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360203

    authors: Wagshul ME,Button TM,Li HF,Liang Z,Springer CS,Zhong K,Wishnia A

    更新日期:1996-08-01 00:00:00

  • Catheter tracking using continuous radial MRI.

    abstract::The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370623

    authors: Rasche V,Holz D,Köhler J,Proksa R,Röschmann P

    更新日期:1997-06-01 00:00:00

  • 4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS).

    abstract::Coronary artery data acquisition with steady-state free precession (SSFP) is typically performed in a single frame in mid-diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient respons...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20627

    authors: Park J,Larson AC,Zhang Q,Simonetti O,Li D

    更新日期:2005-10-01 00:00:00

  • Proton NMR spectroscopy of solvent-saturable resonances: a new approach to study pH effects in situ.

    abstract::It is shown that the effect of pH changes can be measured in proton NMR spectra through the pH sensitivity of the signal intensities of metabolite protons exchanging with water. To observe this phenomenon, pulse sequences must be used that can sensitively observe these exchangeable protons under physiological conditio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400105

    authors: Mori S,Eleff SM,Pilatus U,Mori N,van Zijl PC

    更新日期:1998-07-01 00:00:00

  • Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

    abstract:PURPOSE:To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS:A metric based on patient-specifi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25366

    authors: Weavers PT,Borisch EA,Riederer SJ

    更新日期:2015-06-01 00:00:00

  • Efficient biphasic spin-echo magnetic resonance imaging.

    abstract::The concept of temporal echo multiplexing is defined and used to develop rapid biphasic spin-echo sequences for imaging the heart. Three imaging sequences, based on four-echo and two-echo multiplexing and rapid single echo (i.e., conventional spin-echo imaging), are compared. Preliminary results indicate that two-echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110109

    authors: Parker DL,Caputo GR,Frederick PR

    更新日期:1989-07-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

    abstract::This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24362

    authors: Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

    更新日期:2013-05-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • A two-stage approach for measuring vascular water exchange and arterial transit time by diffusion-weighted perfusion MRI.

    abstract::Changes in the exchange rate of water across the blood-brain barrier, denoted k(w), may indicate blood-brain barrier dysfunction before the leakage of large-molecule contrast agents is observable. A previously proposed approach for measuring k(w) is to use diffusion-weighted arterial spin labeling to measure the vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23104

    authors: St Lawrence KS,Owen D,Wang DJ

    更新日期:2012-05-01 00:00:00

  • Quantitative diffusion imaging in implanted human breast tumors.

    abstract::Quantitative diffusion measurements were performed in tumors arising from inoculation of nude mice with two human breast cancer cell lines (MCF7 and T47D) to evaluate the specificity of this technique for characterizing solid tumors. ADC maps were compared to histology and correlated well with gross tumor morphology. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370417

    authors: Maier CF,Paran Y,Bendel P,Rutt BK,Degani H

    更新日期:1997-04-01 00:00:00

  • MRI: the development of T2 contrast with rapid field echo sequences.

    abstract::The soft tissue contrast obtained in fast imaging using rapidly repeated partial saturation sequences is usually based on differences in T1. We describe here an extension of the method which results in the development of clinically useful T2-based contrast. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040404

    authors: Young IR,Payne JA,Collins AG,Bydder GM

    更新日期:1987-04-01 00:00:00

  • A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

    abstract:PURPOSE:We describe a 2 × 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26017

    authors: Brown R,Lakshmanan K,Madelin G,Alon L,Chang G,Sodickson DK,Regatte RR,Wiggins GC

    更新日期:2016-10-01 00:00:00

  • Cardiac tagging with breath-hold cine MRI.

    abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280214

    authors: McVeigh ER,Atalar E

    更新日期:1992-12-01 00:00:00

  • Simultaneous T(1) and B(1) (+) mapping using reference region variable flip angle imaging.

    abstract:PURPOSE:To present a new method that can simultaneously and efficiently measure T1 and B1 (+) maps using reference region variable flip angle (RR-VFA) imaging. METHODS:Assuming T1 relaxation time in a reference region such as fat is well characterized, and the reference region sufficiently covers smoothly varying B1 (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24904

    authors: Sung K,Saranathan M,Daniel BL,Hargreaves BA

    更新日期:2013-10-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

    abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24137

    authors: Song T,Stainsby JA,Ho VB,Hood MN,Slavin GS

    更新日期:2012-03-01 00:00:00

  • On the application of chemical shift-based multipoint water-fat separation methods in balanced SSFP imaging.

    abstract::Chemical shift-based multipoint water-fat separation methods have been applied in balanced steady-state free precession (bSSFP) sequences because of the high signal-to-noise-ratio (SNR) attainable. In this approach the echo formation is approximated to occur concurrently for both water and fat at an echo time (TE) equ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21303

    authors: Kim H,Pinus AB,Wang J,Murphy PS,Constable RT

    更新日期:2007-08-01 00:00:00

  • Echo shape analysis and image size adjustment on the level of echoes: improvement of parameter-selective proton images.

    abstract::Parameter-selective imaging for tissue characterization is performed at low magnetic fields (0.24-0.28 T) employing echo trains with a large number of echoes (less than or equal to 50), high-power pulses, and the projection reconstruction method. Preprocessing of the raw echoes is important for the quality of the echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030306

    authors: Staemmler M,Gersonde K

    更新日期:1986-06-01 00:00:00

  • Capillarization of the sinusoids in liver fibrosis: noninvasive assessment with contrast-enhanced MRI in the rabbit.

    abstract::Sinusoidal capillarization induces microcirculatory changes in liver cirrhosis and fibrosis. The purpose of this study was to assess whether contrast-enhanced MRI can be used to demonstrate the effects of sinusoidal capillarization in liver fibrosis. Dynamic MRI after injection of a low-molecular-weight contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10420

    authors: Van Beers BE,Materne R,Annet L,Hermoye L,Sempoux C,Peeters F,Smith AM,Jamart J,Horsmans Y

    更新日期:2003-04-01 00:00:00

  • Quantitative chemical exchange saturation transfer MRI of intervertebral disc in a porcine model.

    abstract:PURPOSE:Previous studies have associated low pH in intervertebral discs (IVDs) with discogenic back pain. The purpose of this study was to determine whether quantitative CEST (qCEST) MRI can be used to detect pH changes in IVDs in vivo. METHODS:The exchange rate ksw between glycosaminoglycan (GAG) protons and water pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26457

    authors: Zhou Z,Bez M,Tawackoli W,Giaconi J,Sheyn D,de Mel S,Maya MM,Pressman BD,Gazit Z,Pelled G,Gazit D,Li D

    更新日期:2016-12-01 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00