Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing.

Abstract:

PURPOSE:Dynamic phosphorus MR spectroscopic imaging (31 P-MRSI) experiments require temporal resolution on the order of seconds to concurrently assess different muscle groups. A highly accelerated pulse sequence combining flyback echo-planar spectroscopic imaging (EPSI) and compressed sensing was developed and tested in a phantom and healthy humans during an exercise-recovery challenge of the lower leg muscles, using a clinical 3T MRI. METHODS:A flyback EPSI readout designed to achieve 2.25 × 2.25 cm2 resolution over a 18 × 18 cm2 field of view (i.e., 8 × 8 matrix) was combined with compressed sensing through the inclusion of pseudorandom gradient blips to sub-sample the ky-kt dimensions by a factor of 2.7×, achieving a temporal resolution of 9 s. The sequence was first tested in a phantom to assess performance compared to fully sampled EPSI (fidEPSI) and phase encoded chemical shift imaging (fidCSI). Then, tests were performed in 11 healthy volunteers during an exercise-recovery challenge of the lower leg muscles. Voxels containing tissue from different muscle groups were evaluated measuring percentage phosphocreatine (%PCr) depletion, time constant of PCr recovery (τPCr) and intracellular pH at rest and following exercise. RESULTS:The sequence was capable to track the dynamic PCr response of multiple muscles simultaneously. No statistical differences were found in the metabolite ratio, pH or linewidth when compared with fidEPSI and fidCSI in the phantom study. Dynamic experiments showed differences in PCr depletion when comparing soleus with gastrocnemius muscles. Intracellular pH, τPCr and %PCr decrease were consistent with reported values. CONCLUSION:Highly accelerated 31 P-MRSI combining flyback EPSI and compressed sensing is capable of assessing concurrent energy metabolism in multiple muscle groups using a clinical 3T MR system.

journal_name

Magn Reson Med

authors

Santos-Díaz A,Harasym D,Noseworthy MD

doi

10.1002/mrm.27682

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

3453-3461

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

81

pub_type

杂志文章
  • Modulation of the pharmacokinetics of macromolecular contrast material by avidin chase: MRI, optical, and inductively coupled plasma mass spectrometry tracking of triply labeled albumin.

    abstract::The goal of this work was to develop an MRI method for mapping the clearance of interstitial macromolecular plasma proteins after their extravasation from permeable blood vessels. To that end, a well-defined window of exposure to elevated blood levels was generated by inducing rapid clearance of macromolecular contras...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10638

    authors: Dafni H,Gilead A,Nevo N,Eilam R,Harmelin A,Neeman M

    更新日期:2003-11-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • Evaluation of MRI resolution affecting trabecular bone parameters: determination of acceptable resolution.

    abstract::The objective of this study is to evaluate the effect of MR image resolution on trabecular bone parameters and to determine the acceptable resolution that can be accurately analyzed to assess structural parameters. Ten distal femoral condyle specimens of 1 × 1 × 1 cm(3) were scanned with a 4.7-T Bruker BioSpec MRI sca...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22984

    authors: Kim N,Lee JG,Song Y,Kim HJ,S Yeom J,Cho G

    更新日期:2012-01-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • MR-guided interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe.

    abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390304

    authors: Tacke J,Adam G,Speetzen R,Brucksch K,Bücker A,Heshel I,Prescher A,van Vaals JJ,Hunter DW,Rau G,Günther RW

    更新日期:1998-03-01 00:00:00

  • A new design and rationale for 3D orthogonally oversampled k-space trajectories.

    abstract::A novel center-out 3D trajectory for sampling magnetic resonance data is presented. The trajectory set is based on a single Fermat spiral waveform, which is substantially undersampled in the center of k-space. Multiple trajectories are combined in a "stacked cone" configuration to give very uniform sampling throughout...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22918

    authors: Pipe JG,Zwart NR,Aboussouan EA,Robison RK,Devaraj A,Johnson KO

    更新日期:2011-11-01 00:00:00

  • Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

    abstract::Developing a method to noninvasively monitor tissue-engineered constructs is critical for the optimization of construct design and for assessing therapeutic efficacy. For this purpose, NMR is a powerful technique that can be used to obtain both images and spectroscopic data. But the inherent sensitivity of NMR limits ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22268

    authors: Volland NA,Mareci TH,Constantinidis I,Simpson NE

    更新日期:2010-04-01 00:00:00

  • Apparent changes of appearance of inversion-recovery images.

    abstract::This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020110

    authors: Young IR,Bailes DR,Bydder GM

    更新日期:1985-02-01 00:00:00

  • High-resolution 1 H-MRSI of the brain using short-TE SPICE.

    abstract:PURPOSE:To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS:The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26130

    authors: Ma C,Lam F,Ning Q,Johnson CL,Liang ZP

    更新日期:2017-02-01 00:00:00

  • Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

    abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21194

    authors: Devasahayam N,Subramanian S,Murugesan R,Hyodo F,Matsumoto K,Mitchell JB,Krishna MC

    更新日期:2007-04-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • Echo-planar time course MRI of cat brain oxygenation changes.

    abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220117

    authors: Turner R,Le Bihan D,Moonen CT,Despres D,Frank J

    更新日期:1991-11-01 00:00:00

  • Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion.

    abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27058

    authors: He X,Wengler K,Schweitzer ME

    更新日期:2018-08-01 00:00:00

  • A unique anisotropic R2 of collagen degeneration (ARCADE) mapping as an efficient alternative to composite relaxation metric (R2 -R1 ρ ) in human knee cartilage study.

    abstract:PURPOSE:Anisotropic transverse R2 (1/T2 ) relaxation of water proton is sensitive to cartilage degenerative changes. The purpose is to develop an efficient method to extract this relaxation metric in clinical studies. METHODS:Anisotropic R2 can be measured inefficiently by standard R2 mapping after removing an isotrop...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27621

    authors: Pang Y,Palmieri-Smith RM,Malyarenko DI,Swanson SD,Chenevert TL

    更新日期:2019-06-01 00:00:00

  • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

    abstract::With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320613

    authors: Atalar E,McVeigh ER

    更新日期:1994-12-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Assessment of exposure to MRI motion-induced fields based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.

    abstract:PURPOSE:The goal of this study was to conduct an exposure assessment for workers moving through the stray stationary field of common MRI scanners, performed according to the recent International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines, which aim at avoiding annoying sensory effects. THEORY ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26031

    authors: Zilberti L,Bottauscio O,Chiampi M

    更新日期:2016-10-01 00:00:00

  • Effect of feature extraction for brain tumor classification based on short echo time 1H MR spectra.

    abstract::This study examines the effect of feature extraction methods prior to automated pattern recognition based on magnetic resonance spectroscopy (MRS) for brain tumor diagnosis. Since individual inspection of spectra is time-consuming and requires specific spectroscopic expertise, the introduction of clinical decision sup...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21626

    authors: Luts J,Poullet JB,Garcia-Gomez JM,Heerschap A,Robles M,Suykens JA,Van Huffel S

    更新日期:2008-08-01 00:00:00

  • Quantification of the extraction fraction for gadopentetate across breast cancer capillaries.

    abstract::To quantify the extraction fraction, E, for gadopentetate across tumor capillaries, R3230 adenocarcinomas were implanted in the mammary fat pads of seven rats. The value of E was determined by using a two-compartment tissue model in which the endothelial transfer coefficient, K(PS) (ml x min(-1) x cc(-1) of tissue), w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400406

    authors: Daldrup HE,Shames DM,Husseini W,Wendland MF,Okuhata Y,Brasch RC

    更新日期:1998-10-01 00:00:00

  • MR imaging with hyperpolarized 3He gas.

    abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330219

    authors: Middleton H,Black RD,Saam B,Cates GD,Cofer GP,Guenther R,Happer W,Hedlund LW,Johnson GA,Juvan K

    更新日期:1995-02-01 00:00:00

  • Design and construction of an innovative brain phantom prototype for MRI.

    abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27464

    authors: Altermatt A,Santini F,Deligianni X,Magon S,Sprenger T,Kappos L,Cattin P,Wuerfel J,Gaetano L

    更新日期:2019-02-01 00:00:00

  • Graphical programming interface: A development environment for MRI methods.

    abstract:PURPOSE:To introduce a multiplatform, Python language-based, development environment called graphical programming interface for prototyping MRI techniques. METHODS:The interface allows developers to interact with their scientific algorithm prototypes visually in an event-driven environment making tasks such as paramet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25528

    authors: Zwart NR,Pipe JG

    更新日期:2015-11-01 00:00:00

  • Low peak power multiband spokes pulses for B1 (+) inhomogeneity-compensated simultaneous multislice excitation in high field MRI.

    abstract:PURPOSE:To design low peak and integrated power simultaneous multislice excitation radiofrequency pulses with transmit field inhomogeneity compensation in high field MRI. THEORY AND METHODS:The "interleaved greedy and local optimization" algorithm for small-tip-angle spokes pulses is extended to design multiband (MB) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25455

    authors: Sharma A,Bammer R,Stenger VA,Grissom WA

    更新日期:2015-09-01 00:00:00

  • Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

    abstract:PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25646

    authors: Deniz CM,Vaidya MV,Sodickson DK,Lattanzi R

    更新日期:2016-01-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • Magnetic resonance-guided thermal surgery.

    abstract::A demonstration of MR guided thermal surgery involved experiments with imaging of focused ultrasound in an MRI system, measurements of the thermal transients and a thermal analysis of the resulting images. Both the heat distribution and the creation of focused ultrasound lesions in gel phantoms, in vitro bovine muscle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300115

    authors: Cline HE,Schenck JF,Watkins RD,Hynynen K,Jolesz FA

    更新日期:1993-07-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00