Apparent changes of appearance of inversion-recovery images.

Abstract:

:This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'.

journal_name

Magn Reson Med

authors

Young IR,Bailes DR,Bydder GM

doi

10.1002/mrm.1910020110

subject

Has Abstract

pub_date

1985-02-01 00:00:00

pages

81-5

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

2

pub_type

杂志文章
  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Dysprosium-bearing red cells as potential transverse relaxation agents for MRI.

    abstract::The cytosol of intact human red blood cells was loaded with 28.1 +/- 3.4 mM of dysprosium DTPA-BMA using a hypoosmotic technique. When loaded cells were diluted with saline and control cells to give an average dysprosium concentration of 3.3 +/- 0.5 mM, the transverse relaxation rate constants R(*)(2) and R(2) increas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1122

    authors: Johnson KM,Tao JZ,Kennan RP,Gore JC

    更新日期:2001-05-01 00:00:00

  • Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling.

    abstract::MR images acquired by using an arterial spin-labeling technique showed spatial and temporal variations of perfusion in the skeletal muscle of exercising humans. Perfusion measurements made during plantar flexion exercise in normal volunteers were consistent with those obtained by traditional techniques reported in the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>

    authors: Frank LR,Wong EC,Haseler LJ,Buxton RB

    更新日期:1999-08-01 00:00:00

  • Biodegradable, polymer encapsulated, metal oxide particles for MRI-based cell tracking.

    abstract::Metallic particles have shaped the use of magnetic resonance imaging (MRI) for molecular and cellular imaging. Although these particles have generally been developed for extracellular residence, either as blood pool contrast agents or targeted contrast agents, the coopted use of these particles for intracellular label...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.25263

    authors: Shapiro EM

    更新日期:2015-01-01 00:00:00

  • Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

    abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24824

    authors: Lee SK,Tan ET,Govenkar A,Hancu I

    更新日期:2014-05-01 00:00:00

  • In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles.

    abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330209

    authors: Yeh TC,Zhang W,Ildstad ST,Ho C

    更新日期:1995-02-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • Sodium NMR imaging of lung water in rats.

    abstract::Coronal proton and sodium images of control rats and rats with either increased permeability edema produced by intravenous alloxan (300 mg/kg) or increased pressure edema produced by saline infusion (2 ml/min) were obtained. Axial chest CT images were used to monitor the development of pulmonary edema. Immediately aft...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060403

    authors: Kundel HL,Shetty A,Joseph PM,Summers RM,Kassab EA,Moore B

    更新日期:1988-04-01 00:00:00

  • Nuclear relaxation of human brain gray and white matter: analysis of field dependence and implications for MRI.

    abstract::The dependence of 1/T1 on the magnetic field strength (the relaxation dispersion) has been measured at 37 degrees C on autopsy samples of human brain gray and white matter at field strengths corresponding to proton Larmor frequencies between 10 kHz and 50 MHz (0.0002-1.2 T). Additional measurements of 1/T1 and 1/T2 ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160212

    authors: Fischer HW,Rinck PA,Van Haverbeke Y,Muller RN

    更新日期:1990-11-01 00:00:00

  • Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema.

    abstract::MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24452

    authors: Iguchi S,Imai H,Hori Y,Nakajima J,Kimura A,Fujiwara H

    更新日期:2013-07-01 00:00:00

  • Cerebral T1rho relaxation time increases immediately upon global ischemia in the rat independently of blood glucose and anoxic depolarization.

    abstract::Time-dependent changes of T1 in the rotating frame (T1rho), diffusion, T2, and magnetization transfer contrast on cardiac arrest-induced global ischemia in rat were investigated. T1rho, as acquired with spin lock amplitudes >0.6 G, started to increase 10-20 sec after cardiac arrest followed by an increase within 3-4 m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1228

    authors: Kettunen MI,Gröhn OH,Penttonen M,Kauppinen RA

    更新日期:2001-09-01 00:00:00

  • Complete elimination of the extracellular 23Na NMR signal in triple quantum filtered spectra of rat hearts in the presence of shift reagents.

    abstract::A method is suggested whereby the shifted extracellular triple quantum filtered 23Na signal of an isolated organ is completely eliminated. The method is based on the long relaxation time of the triple quantum coherence and on its fast evolution rate. When the carrier frequency is set on top of the intracellular sodium...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300415

    authors: Navon G

    更新日期:1993-10-01 00:00:00

  • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

    abstract::Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20615

    authors: Markl M,Leupold J,Bieri O,Scheffler K,Hennig J

    更新日期:2005-10-01 00:00:00

  • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24440

    authors: Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim D

    更新日期:2013-07-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    abstract::Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surroun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23235

    authors: Langman DA,Goldberg IB,Judy J,Paul Finn J,Ennis DB

    更新日期:2012-08-01 00:00:00

  • Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

    abstract:PURPOSE:To develop and evaluate a novel two-dimensional self-gated imaging technique for free-breathing cardiac cine MRI that is free of motion-detection overhead and requires minimal planning for motion tracking. METHODS:Motion along the readout direction was extracted solely from normal Cartesian imaging readouts ne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25834

    authors: Guo L,Derbyshire JA,Herzka DA

    更新日期:2016-08-01 00:00:00

  • SLIP, a lipid suppression technique to improve image contrast in inflow angiography.

    abstract::In rapidly acquired gradient echo images, lipid regions usually appear as areas of high signal intensity. In 2D inflow angiograms processed by the maximum intensity projection algorithm, this high lipid signal may prevent angiographic visualization of some blood vessels. We present a new approach to suppress the lipid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210110

    authors: Doyle M,Matsuda T,Pohost GM

    更新日期:1991-09-01 00:00:00

  • Design and construction of an innovative brain phantom prototype for MRI.

    abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27464

    authors: Altermatt A,Santini F,Deligianni X,Magon S,Sprenger T,Kappos L,Cattin P,Wuerfel J,Gaetano L

    更新日期:2019-02-01 00:00:00

  • Sampling errors in projection reconstruction MRI.

    abstract::Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400317

    authors: Joseph PM

    更新日期:1998-09-01 00:00:00

  • Simultaneous T(1) and B(1) (+) mapping using reference region variable flip angle imaging.

    abstract:PURPOSE:To present a new method that can simultaneously and efficiently measure T1 and B1 (+) maps using reference region variable flip angle (RR-VFA) imaging. METHODS:Assuming T1 relaxation time in a reference region such as fat is well characterized, and the reference region sufficiently covers smoothly varying B1 (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24904

    authors: Sung K,Saranathan M,Daniel BL,Hargreaves BA

    更新日期:2013-10-01 00:00:00

  • Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

    abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22809

    authors: Fluckiger JU,Schabel MC,DiBella EV

    更新日期:2011-08-01 00:00:00

  • Noise removal in magnetic resonance diffusion tensor imaging.

    abstract::Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20582

    authors: Chen B,Hsu EW

    更新日期:2005-08-01 00:00:00

  • Improved steering of the RF field of traveling wave MR with a multimode, coaxial waveguide.

    abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24807

    authors: Andreychenko A,Kroeze H,Boer VO,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-04-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • Characterization of anomalous relaxation using the time-fractional Bloch equation and multiple echo T2 *-weighted magnetic resonance imaging at 7 T.

    abstract:PURPOSE:To study the utility of fractional calculus in modeling gradient-recalled echo MRI signal decay in the normal human brain. METHODS:We solved analytically the extended time-fractional Bloch equations resulting in five model parameters, namely, the amplitude, relaxation rate, order of the time-fractional derivat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26222

    authors: Qin S,Liu F,Turner IW,Yu Q,Yang Q,Vegh V

    更新日期:2017-04-01 00:00:00

  • Optimization of survey protocols for MRI.

    abstract::A method for evaluating the sensitivity of MRI protocols to changes in an arbitrary number of tissue parameters over a broad range of parameter values is presented. This analysis is useful for choosing an optimal basis set of images for either a "survey" protocol or tissue segmentation algorithms. A survey protocol is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130202

    authors: McVeigh ER,Henkelman RM,Bronskill MJ

    更新日期:1990-02-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • MR angiography by selective inversion recovery.

    abstract::A modified inversion-recovery sequence is introduced which performs subtraction angiography by varying time-of-flight effects of blood flowing into an imaged slab. The selective 180 degrees excitation inverts different regions between measurements to isolate arterial and/or venous blood. On normal human subjects, high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040214

    authors: Nishimura DG,Macovski A,Pauly JM,Conolly SM

    更新日期:1987-02-01 00:00:00