Abstract:
:A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminates this potential source of artifacts without spoiling the correctly timed stimulated echoes, which, similar to RARE (TSE) sequences, add coherently to the primary echoes. Comparisons show equivalent artifact elimination using phase cycling, periodic spoiling, and a previously developed spoiling scheme for non-Carr-Purcell-Meiboom-Gill sequences. A comparison of head images at 1.5 T acquired with SER-TSE and conventional TSE T1-weighted sequences show no degradation in image quality nor SNR. T2-weighted imaging is not achievable with the current implementation, but possible solutions are proposed. The proposed technique might prove especially beneficial at higher field strengths, where the reduced number of refocusing pulses for multislice SER-TSE decreases RF power deposition. SER spin-echo imaging offers an approach that is very different from low flip angle imaging to mitigate RF heating limitations in high-field clinical imaging.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Günther M,Feinberg DAdoi
10.1002/mrm.20587subject
Has Abstractpub_date
2005-09-01 00:00:00pages
513-23issue
3eissn
0740-3194issn
1522-2594journal_volume
54pub_type
杂志文章abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.20998
更新日期:2006-09-01 00:00:00
abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320518
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26562
更新日期:2017-11-01 00:00:00
abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22971
更新日期:2011-12-01 00:00:00
abstract::A single-shot, two-echo method for the simultaneous detection of multiple-quantum (MQ)-filtered gamma-aminobutyric acid (GABA) and creatine (Cr) was developed and demonstrated in the human brain in vivo at 3 Tesla. The simultaneously measured Cr singlet served as a navigator for the spectral phase of GABA and any freq...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20082
更新日期:2004-06-01 00:00:00
abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co
更新日期:2000-09-01 00:00:00
abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26910
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:This study evaluates biochemical imbalances in a rat model that reflects dysfunctional pathways in migraine. The high sensitivity and spectral dispersion available to 1 H MRS at 21.1 T expands metabolic profiling in this migraine model to include lactate (Lac), taurine (Tau), aspartate, and Gly-a mixture of gly...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26811
更新日期:2018-03-01 00:00:00
abstract::Head motion is a fundamental problem in functional magnetic resonance imaging and is often a limiting factor in its clinical implementation. This work presents a rigid-body motion correction strategy for echo-planar imaging sequences that uses micro radiofrequency coil "active markers" for real-time, slice-by-slice pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22780
更新日期:2011-07-01 00:00:00
abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24546
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD(+) ) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD(+) /NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo (31) P MRS method for noninvasive measu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24859
更新日期:2014-06-01 00:00:00
abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24134
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1 /T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method. METHODS:Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and ac...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28321
更新日期:2020-11-01 00:00:00
abstract:PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pul...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27555
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26785
更新日期:2018-03-01 00:00:00
abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20221
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, u...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27001
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26903
更新日期:2018-05-01 00:00:00
abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22876
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28455
更新日期:2021-02-01 00:00:00
abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370404
更新日期:1997-04-01 00:00:00
abstract::Combined MRI and 3D spectroscopic imaging (MRI/3D-MRSI) was used to study the metabolic effects of hormone-deprivation therapy in 65 prostate cancer patients, who underwent either short, intermediate, or long-term therapy, compared to 30 untreated control patients. There was a significant time-dependent loss of the pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1159
更新日期:2001-07-01 00:00:00
abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22779
更新日期:2011-07-01 00:00:00
abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.10319
更新日期:2002-12-01 00:00:00
abstract::The relaxation of (1)H nuclei due to their interaction with quadrupolar (14)N nuclei in gel structures is measured using fast field-cycling NMR. This phenomenon called quadrupolar dips has been reported in different (1)H-(14)N bond-rich species. In this study, we have studied quadrupolar dips in fibrin, an insoluble p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23117
更新日期:2012-05-01 00:00:00
abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4
更新日期:1999-06-01 00:00:00
abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030302
更新日期:1986-06-01 00:00:00
abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360617
更新日期:1996-12-01 00:00:00
abstract:PURPOSE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models we...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28395
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26749
更新日期:2018-02-01 00:00:00