Simultaneous spin-echo refocusing.

Abstract:

:A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminates this potential source of artifacts without spoiling the correctly timed stimulated echoes, which, similar to RARE (TSE) sequences, add coherently to the primary echoes. Comparisons show equivalent artifact elimination using phase cycling, periodic spoiling, and a previously developed spoiling scheme for non-Carr-Purcell-Meiboom-Gill sequences. A comparison of head images at 1.5 T acquired with SER-TSE and conventional TSE T1-weighted sequences show no degradation in image quality nor SNR. T2-weighted imaging is not achievable with the current implementation, but possible solutions are proposed. The proposed technique might prove especially beneficial at higher field strengths, where the reduced number of refocusing pulses for multislice SER-TSE decreases RF power deposition. SER spin-echo imaging offers an approach that is very different from low flip angle imaging to mitigate RF heating limitations in high-field clinical imaging.

journal_name

Magn Reson Med

authors

Günther M,Feinberg DA

doi

10.1002/mrm.20587

subject

Has Abstract

pub_date

2005-09-01 00:00:00

pages

513-23

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

54

pub_type

杂志文章
  • Efficient visualization of vascular territories in the human brain by cycled arterial spin labeling MRI.

    abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20998

    authors: Günther M

    更新日期:2006-09-01 00:00:00

  • Echo-volume imaging.

    abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320518

    authors: Song AW,Wong EC,Hyde JS

    更新日期:1994-11-01 00:00:00

  • Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND).

    abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26562

    authors: Zeng X,Barbic M,Chen L,Qian C

    更新日期:2017-11-01 00:00:00

  • Results for diffusion-weighted imaging with a fourth-channel gradient insert.

    abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22971

    authors: Feldman RE,Scholl TJ,Alford JK,Handler WB,Harris CT,Chronik BA

    更新日期:2011-12-01 00:00:00

  • Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo.

    abstract::A single-shot, two-echo method for the simultaneous detection of multiple-quantum (MQ)-filtered gamma-aminobutyric acid (GABA) and creatine (Cr) was developed and demonstrated in the human brain in vivo at 3 Tesla. The simultaneously measured Cr singlet served as a navigator for the spectral phase of GABA and any freq...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20082

    authors: Choi IY,Lee SP,Merkle H,Shen J

    更新日期:2004-06-01 00:00:00

  • Single-shot, three-dimensional "non-echo" localization method for in vivo NMR spectroscopy.

    abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co

    authors: Choi IY,Tkác I,Gruetter R

    更新日期:2000-09-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Metabolic assessment of a migraine model using relaxation-enhanced 1 H spectroscopy at ultrahigh field.

    abstract:PURPOSE:This study evaluates biochemical imbalances in a rat model that reflects dysfunctional pathways in migraine. The high sensitivity and spectral dispersion available to 1 H MRS at 21.1 T expands metabolic profiling in this migraine model to include lactate (Lac), taurine (Tau), aspartate, and Gly-a mixture of gly...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26811

    authors: Abad N,Rosenberg JT,Roussel T,Grice DC,Harrington MG,Grant SC

    更新日期:2018-03-01 00:00:00

  • Echo-planar imaging with prospective slice-by-slice motion correction using active markers.

    abstract::Head motion is a fundamental problem in functional magnetic resonance imaging and is often a limiting factor in its clinical implementation. This work presents a rigid-body motion correction strategy for echo-planar imaging sequences that uses micro radiofrequency coil "active markers" for real-time, slice-by-slice pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22780

    authors: Ooi MB,Krueger S,Muraskin J,Thomas WJ,Brown TR

    更新日期:2011-07-01 00:00:00

  • Kinetic modeling of hyperpolarized (13)C pyruvate metabolism in tumors using a measured arterial input function.

    abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24546

    authors: Kazan SM,Reynolds S,Kennerley A,Wholey E,Bluff JE,Berwick J,Cunningham VJ,Paley MN,Tozer GM

    更新日期:2013-10-01 00:00:00

  • Intracellular redox state revealed by in vivo (31) P MRS measurement of NAD(+) and NADH contents in brains.

    abstract:PURPOSE:Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD(+) ) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD(+) /NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo (31) P MRS method for noninvasive measu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24859

    authors: Lu M,Zhu XH,Zhang Y,Chen W

    更新日期:2014-06-01 00:00:00

  • Tuning and amplification strategies for intravascular imaging coils.

    abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24134

    authors: Yak N,Anderson KJ,Wright GA

    更新日期:2012-11-01 00:00:00

  • Fast and accurate calculation of myocardial T1 and T2 values using deep learning Bloch equation simulations (DeepBLESS).

    abstract:PURPOSE:To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1 /T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method. METHODS:Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and ac...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28321

    authors: Shao J,Ghodrati V,Nguyen KL,Hu P

    更新日期:2020-11-01 00:00:00

  • A new approach to Z-spectrum acquisition: prospective baseline enhancement (PROBE) for CEST/Nuclear Overhauser Effect.

    abstract:PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27555

    authors: Lenich T,Pampel A,Mildner T,Möller HE

    更新日期:2019-04-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

    abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20221

    authors: Jochimsen TH,Norris DG,Mildner T,Möller HE

    更新日期:2004-10-01 00:00:00

  • Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    abstract:PURPOSE:T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27001

    authors: Gras V,Mauconduit F,Vignaud A,Amadon A,Le Bihan D,Stöcker T,Boulant N

    更新日期:2018-07-01 00:00:00

  • Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

    abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26903

    authors: Bane O,Hectors SJ,Wagner M,Arlinghaus LL,Aryal MP,Cao Y,Chenevert TL,Fennessy F,Huang W,Hylton NM,Kalpathy-Cramer J,Keenan KE,Malyarenko DI,Mulkern RV,Newitt DC,Russek SE,Stupic KF,Tudorica A,Wilmes LJ,Yankeelov TE

    更新日期:2018-05-01 00:00:00

  • A molecular MRI probe to detect treatment of cardiac apoptosis in vivo.

    abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22876

    authors: Dash R,Chung J,Chan T,Yamada M,Barral J,Nishimura D,Yang PC,Simpson PC

    更新日期:2011-10-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

    abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370404

    authors: Hopkins JA,Wehrli FW

    更新日期:1997-04-01 00:00:00

  • Time-dependent effects of hormone-deprivation therapy on prostate metabolism as detected by combined magnetic resonance imaging and 3D magnetic resonance spectroscopic imaging.

    abstract::Combined MRI and 3D spectroscopic imaging (MRI/3D-MRSI) was used to study the metabolic effects of hormone-deprivation therapy in 65 prostate cancer patients, who underwent either short, intermediate, or long-term therapy, compared to 30 untreated control patients. There was a significant time-dependent loss of the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1159

    authors: Mueller-Lisse UG,Swanson MG,Vigneron DB,Hricak H,Bessette A,Males RG,Wood PJ,Noworolski S,Nelson SJ,Barken I,Carroll PR,Kurhanewicz J

    更新日期:2001-07-01 00:00:00

  • Investigating temporal fluctuations in tumor vasculature with combined carbogen and ultrasmall superparamagnetic iron oxide particle (CUSPIO) imaging.

    abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22779

    authors: Burrell JS,Walker-Samuel S,Baker LC,Boult JK,Ryan AJ,Waterton JC,Halliday J,Robinson SP

    更新日期:2011-07-01 00:00:00

  • Application of image registration to measurement of intervertebral rotation in the lumbar spine.

    abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10319

    authors: Rogers BP,Haughton VM,Arfanakis K,Meyerand ME

    更新日期:2002-12-01 00:00:00

  • Measurement of fibrin concentration by fast field-cycling NMR.

    abstract::The relaxation of (1)H nuclei due to their interaction with quadrupolar (14)N nuclei in gel structures is measured using fast field-cycling NMR. This phenomenon called quadrupolar dips has been reported in different (1)H-(14)N bond-rich species. In this study, we have studied quadrupolar dips in fibrin, an insoluble p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23117

    authors: Broche LM,Ismail SR,Booth NA,Lurie DJ

    更新日期:2012-05-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00

  • Effects of polar sampling in k-space.

    abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360617

    authors: Lauzon ML,Rutt BK

    更新日期:1996-12-01 00:00:00

  • Training a neural network for Gibbs and noise removal in diffusion MRI.

    abstract:PURPOSE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28395

    authors: Muckley MJ,Ades-Aron B,Papaioannou A,Lemberskiy G,Solomon E,Lui YW,Sodickson DK,Fieremans E,Novikov DS,Knoll F

    更新日期:2021-01-01 00:00:00

  • Oxygen extraction fraction mapping at 3 Tesla using an artificial neural network: A feasibility study.

    abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26749

    authors: Domsch S,Mürle B,Weingärtner S,Zapp J,Wenz F,Schad LR

    更新日期:2018-02-01 00:00:00