Rigid-body motion correction with self-navigation MRI.

Abstract:

:The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred between the acquisitions of the two echotrains can be measured. It is shown further that a similar correlation can be found between two sets of equally spaced measurements that are adjacent in k-space. By measuring the motion between all adjacent pairs of k-space subgroups, the complete motion history of a subject can be determined and the motion artifacts in the image can be corrected. Some of the limiting factors in using this technique are investigated with turbo-spin-echo head and hand images.

journal_name

Magn Reson Med

authors

Mendes J,Kholmovski E,Parker DL

doi

10.1002/mrm.21883

subject

Has Abstract

pub_date

2009-03-01 00:00:00

pages

739-47

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

61

pub_type

杂志文章
  • NMR investigation of hydroxyethyl starch-induced aggregation of human erythrocytes.

    abstract::Aggregation of human erythrocytes at physiological hematocrit by hydroxyethyl starch (HES) was investigated with a 1H nuclear magnetic resonance method which measures the erythrocyte mean water exchange time, tau a. A relationship that takes into account the effect of the aggregate as the water-exchanging unit was use...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050108

    authors: Caines GH,Goldstein JH

    更新日期:1987-07-01 00:00:00

  • Uncertainties of calculated Cramér-Rao lower bounds: implications for quantitative MRS.

    abstract:PURPOSE:To investigate the uncertainties on relative Cramér-Rao lower bound (rCRB) estimates and demonstrate their biasing effects in MRS quantification. THEORY AND METHODS:Simulations were performed to calculate the distribution of the computed rCRB (noted rCRB*) for several rCRB levels. One hundred thousand simulati...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27415

    authors: Bonny JM,Pagès G

    更新日期:2019-02-01 00:00:00

  • Characterization of aortic root atherosclerosis in ApoE knockout mice: high-resolution in vivo and ex vivo MRM with histological correlation.

    abstract::In vivo, cardiac-gated, black-blood, and ex vivo magnetic resonance microscopy (MRM) images of the aortic root, and histopathology data were obtained from 12 transgenic and wild-type (WT) mice. MRM was performed using a black-blood imaging spin-echo sequence with upstream and downstream in-flow saturation pulses to ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10360

    authors: Itskovich VV,Choudhury RP,Aguinaldo JG,Fallon JT,Omerhodzic S,Fisher EA,Fayad ZA

    更新日期:2003-02-01 00:00:00

  • Relaxation effects of ferucarbotran-labeled mesenchymal stem cells at 1.5T and 3T: discrimination of viable from lysed cells.

    abstract::Human mesenchymal stem cells (hMSCs) were labeled with Ferucarbotran by simple incubation and cultured for up to 14 d. Iron content was determined by spectrometry and the intracellular localization of the contrast agent uptake was studied by electron and confocal microscopy. At various time points after labeling, rang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22011

    authors: Henning TD,Wendland MF,Golovko D,Sutton EJ,Sennino B,Malek F,Bauer JS,McDonald DM,Daldrup-Link H

    更新日期:2009-08-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

    abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28139

    authors: Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

    更新日期:2020-08-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Transmit and receive RF fields determination from a single low-tip-angle gradient-echo scan by scaling of SVD data.

    abstract:PURPOSE:A new method, called Transmit and Receive Patterns from Low-Tip-angle gradient-Echo Images (TRIPLET), is described which simultaneously maps the B1+ and B1- fields of a transmit/receive radiofrequency coil array. The input data are low-tip-angle gradient-echo images, which can be acquired in a relatively short ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24912

    authors: Sbrizzi A,Raaijmakers AJ,Hoogduin H,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-07-01 00:00:00

  • On multiple alternating steady states induced by periodic spin phase perturbation waveforms.

    abstract::Direct measurement of neural currents by means of MRI can potentially open a high temporal resolution (10-100 ms) window applicable for monitoring dynamics of neuronal activity without loss of the high spatial resolution afforded by MRI. Previously, we have shown that the alternating balanced steady state imaging affo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23105

    authors: Buračas GT,Jung Y,Lee J,Buxton RB,Wong EC,Liu TT

    更新日期:2012-05-01 00:00:00

  • Measuring extracellular volume fraction by MRI: First verification of values given by clinical sequences.

    abstract:PURPOSE:To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers. METHODS:Between May 2016 and March 2017, 8 volunteers (25 ± 4 years,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27938

    authors: Nordlund D,Xanthis C,Bidhult S,Jablonowski R,Kanski M,Kopic S,Carlsson M,Engblom H,Aletras AH,Arheden H

    更新日期:2020-02-01 00:00:00

  • Cerebrospinal fluid pulse wave velocity measurements: In vitro and in vivo evaluation of a novel multiband cine phase-contrast MRI sequence.

    abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28430

    authors: Sonnabend K,Brinker G,Maintz D,Bunck AC,Weiss K

    更新日期:2021-01-01 00:00:00

  • Quantification of the pulse wave velocity of the descending aorta using axial velocity profiles from phase-contrast magnetic resonance imaging.

    abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21034

    authors: Yu HY,Peng HH,Wang JL,Wen CY,Tseng WY

    更新日期:2006-10-01 00:00:00

  • Effects of anesthesia on renal function and metabolism in rats assessed by hyperpolarized MRI.

    abstract:PURPOSE:Anesthesia is necessary for most animal studies requiring invasive procedures. It is well documented that various types of anesthesia modulate a wide variety of important metabolic and functional processes in the body, and as such, represent a potential limitation in the study design. In the present study, we a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27165

    authors: Qi H,Mariager CØ,Lindhardt J,Nielsen PM,Stødkilde-Jørgensen H,Laustsen C

    更新日期:2018-11-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • 31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

    abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050405

    authors: Shapiro JI,Haug CE,Weil R 3rd,Chan L

    更新日期:1987-10-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Half-Fourier single-shot STEAM MRI.

    abstract::As a high-speed imaging technique based on stimulated echoes single-shot STEAM MRI is insensitive to chemical shift artifacts and magnetic susceptibility differences. The achievable signal-to-noise ratio (SNR) is limited by the fact that high flip angles of the read-out excitation pulses cause a steep decay of the sti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10090

    authors: Finsterbusch J,Frahm J

    更新日期:2002-03-01 00:00:00

  • Imaging oxygen tension in liver and spleen by 19F NMR.

    abstract::19F NMR imaging of the perfluorocarbon emulsion Fluosol has been used to study regional variations in oxygen tension in rat liver and spleen. We have used the linear dependence of spin lattice relaxation rate (1/T1) on the partial oxygen pressure (pO2) of Fluosol to determine the oxygen tension in the reticuloendothel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290405

    authors: Holland SK,Kennan RP,Schaub MM,D'Angelo MJ,Gore JC

    更新日期:1993-04-01 00:00:00

  • Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

    abstract:PURPOSE:To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully sampled data sets. METHODS:Self-supervised learning via data undersampling (SSDU) for physics-guided deep learning reconstruction partitions available measurements into two disjoint sets, one of wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28378

    authors: Yaman B,Hosseini SAH,Moeller S,Ellermann J,Uğurbil K,Akçakaya M

    更新日期:2020-12-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • Rapid in vivo musculoskeletal MR with parallel imaging at 7T.

    abstract::The purpose of this work was to implement autocalibrating GRAPPA-based parallel imaging (PI) for in vivo high-resolution (HR) MRI of cartilage and trabecular bone micro-architecture at 7T and to evaluate its performance based on comparison of MR-derived morphology metrics between accelerated and conventional images an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21455

    authors: Banerjee S,Krug R,Carballido-Gamio J,Kelley DA,Xu D,Vigneron DB,Majumdar S

    更新日期:2008-03-01 00:00:00

  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • MRI of [2-13 C]Lactate without J-coupling artifacts.

    abstract:PURPOSE:Imaging of [2-13 C]lactate, a metabolic product of [2-13 C]pyruvate, is over considerable interest in hyperpolarized 13 C studies. However, artifact-free imaging of a J-coupled nuclear spin species can be challenging due to the peak-splitting induced by the spin-spin interactions. In this work, two new techniqu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28532

    authors: Datta K,Spielman D

    更新日期:2021-03-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Effect of distortion corrections on the tractography quality in spinal cord diffusion-weighted imaging.

    abstract:PURPOSE:To assess the impact of a different distortion correction (DC) method and patient geometry (sagittal balance) on the quality of spinal cord tractography rendering according to different tractography approaches. METHODS:Forty-four adults free of spinal cord diseases underwent cervical diffusion-weighted imaging...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28665

    authors: Dauleac C,Bannier E,Cotton F,Frindel C

    更新日期:2021-01-21 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.

    abstract:PURPOSE:Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS:A truly hybrid US...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26897

    authors: Celicanin Z,Manasseh G,Petrusca L,Scheffler K,Auboiroux V,Crowe LA,Hyacinthe JN,Natsuaki Y,Santini F,Becker CD,Terraz S,Bieri O,Salomir R

    更新日期:2018-05-01 00:00:00