31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

Abstract:

:31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was clearly identified by elevations in the phosphodiester/urine phosphate peak. Ischemia and rejection were both associated with increases in inorganic phosphates and phosphomonesters and decreases in the beta-phosphate peak of adenosine triphosphate but were distinguishable from each other by differences in intracellular pH which was normal in rejected allografts (7.33 +/- 0.07, n = 3) but low in ischemic allografts (7.00 +/- 0.05, n = 3, P less than 0.05). Grafts insulted with cyclosporine toxicity were not distinguishable from normal allografts by any of the parameters studied. These data suggest that 31P NMR spectroscopy may have potential clinical application in differentiating among the causes of graft failure of human renal allografts.

journal_name

Magn Reson Med

authors

Shapiro JI,Haug CE,Weil R 3rd,Chan L

doi

10.1002/mrm.1910050405

subject

Has Abstract

pub_date

1987-10-01 00:00:00

pages

346-52

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

5

pub_type

杂志文章
  • Biodegradable, polymer encapsulated, metal oxide particles for MRI-based cell tracking.

    abstract::Metallic particles have shaped the use of magnetic resonance imaging (MRI) for molecular and cellular imaging. Although these particles have generally been developed for extracellular residence, either as blood pool contrast agents or targeted contrast agents, the coopted use of these particles for intracellular label...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.25263

    authors: Shapiro EM

    更新日期:2015-01-01 00:00:00

  • Fast oxygen-enhanced multislice imaging of the lung using parallel acquisition techniques.

    abstract::The purpose of this study was to evaluate an optimized multislice acquisition technique for oxygen-enhanced MRI of the lung using slice-selective inversion and refocusing pulses in combination with parallel imaging. An inversion recovery HASTE sequence was implemented with respiratory triggering to perform imaging in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20495

    authors: Dietrich O,Losert C,Attenberger U,Fasol U,Peller M,Nikolaou K,Reiser MF,Schoenberg SO

    更新日期:2005-06-01 00:00:00

  • PRESTO-SENSE: an ultrafast whole-brain fMRI technique.

    abstract::A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co

    authors: Golay X,Pruessmann KP,Weiger M,Crelier GR,Folkers PJ,Kollias SS,Boesiger P

    更新日期:2000-06-01 00:00:00

  • Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize, and quantify the strain rates of the active human myocardium.

    abstract::A magnetic resonance imaging (MRI) method is presented to detect, localize, and quantify myocardial kinematics by measuring the material rate-of-strain tensor at each pixel in gated NMR images of the heart. The immediate, local effect of muscular activity is self-deformation, and the strain tensor is the basic mathema...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270107

    authors: Wedeen VJ

    更新日期:1992-09-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Theory of heterogeneous relaxation in compartmentalized tissues.

    abstract::A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370507

    authors: Barsky D,Pütz B,Schulten K

    更新日期:1997-05-01 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging for in vivo assessment of damage and functional improvement following spinal cord injury in mice.

    abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20888

    authors: Stieltjes B,Klussmann S,Bock M,Umathum R,Mangalathu J,Letellier E,Rittgen W,Edler L,Krammer PH,Kauczor HU,Martin-Villalba A,Essig M

    更新日期:2006-05-01 00:00:00

  • CINE turbo spin echo imaging.

    abstract::High-resolution turbo spin echo (TSE) images have demonstrated important details of carotid artery morphology; however, it is evident that pulsatile blood and wall motion related to the cardiac cycle are still significant sources of image degradation. Although ECG gating can reduce artifacts due to cardiac-induced pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22909

    authors: Mendes J,Parker DL,Hulet J,Treiman GS,Kim SE

    更新日期:2011-11-01 00:00:00

  • Analytical solution and verification of diffusion effect in SSFP.

    abstract::Assuming that the SSFP magnetization response maintains a steady state which is periodic in the presence of diffusion, we can solve for the diffusion effect in such sequences. Formulating a Fourier series decomposition solution to the Bloch-Torrey equation and imposing the steady-state condition, analytical expression...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190209

    authors: Carney CE,Wong ST,Patz S

    更新日期:1991-06-01 00:00:00

  • Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI.

    abstract::Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10567

    authors: van Osch MJ,Vonken EJ,Wu O,Viergever MA,van der Grond J,Bakker CJ

    更新日期:2003-09-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Sodium NMR imaging of lung water in rats.

    abstract::Coronal proton and sodium images of control rats and rats with either increased permeability edema produced by intravenous alloxan (300 mg/kg) or increased pressure edema produced by saline infusion (2 ml/min) were obtained. Axial chest CT images were used to monitor the development of pulmonary edema. Immediately aft...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060403

    authors: Kundel HL,Shetty A,Joseph PM,Summers RM,Kassab EA,Moore B

    更新日期:1988-04-01 00:00:00

  • The MR tomograph as a sound generator: fMRI tool for the investigation of the auditory cortex.

    abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400621

    authors: Bilecen D,Radü EW,Scheffler K

    更新日期:1998-12-01 00:00:00

  • Conversion of arterial input functions for dual pharmacokinetic modeling using Gd-DTPA/MRI and 18F-FDG/PET.

    abstract::Reaching the full potential of magnetic resonance imaging (MRI)-positron emission tomography (PET) dual modality systems requires new methodologies in quantitative image analyses. In this study, methods are proposed to convert an arterial input function (AIF) derived from gadolinium-diethylenetriaminepentaacetic acid ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24318

    authors: Poulin E,Lebel R,Croteau E,Blanchette M,Tremblay L,Lecomte R,Bentourkia M,Lepage M

    更新日期:2013-03-01 00:00:00

  • Water diffusion, T(2), and compartmentation in frog sciatic nerve.

    abstract::A potential relationship between structural compartments in neural tissue and NMR parameters may increase the specificity of MRI in diagnosing diseases. Nevertheless, our understanding of MR of nerves and white matter is limited, particularly the influence of various water compartments on the MR signal is not known. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199911)42:5<911::aid-mrm11

    authors: Peled S,Cory DG,Raymond SA,Kirschner DA,Jolesz FA

    更新日期:1999-11-01 00:00:00

  • Application of parallel imaging to fMRI at 7 Tesla utilizing a high 1D reduction factor.

    abstract::Gradient-echo EPI, blood oxygenation level-dependent (BOLD) functional MRI (fMRI) using parallel imaging (PI) is demonstrated at 7 Tesla with 16 channels, a fourfold 1D reduction factor (R), and fourfold maximal aliasing. The resultant activation detection in finger-tapping fMRI studies was robust, in full agreement w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20934

    authors: Moeller S,Van de Moortele PF,Goerke U,Adriany G,Ugurbil K

    更新日期:2006-07-01 00:00:00

  • Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging.

    abstract:PURPOSE:MUSSELS is a one-step iterative reconstruction method for multishot diffusion weighted (msDW) imaging. The current work presents an efficient implementation, termed IRLS MUSSELS, that enables faster reconstruction to enhance its utility for high-resolution diffusion MRI studies. METHODS:The recently proposed M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28090

    authors: Mani M,Aggarwal HK,Magnotta V,Jacob M

    更新日期:2020-06-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26559

    authors: Wang Y,Zhang Y,Zhao X,Wu B,Gao JH

    更新日期:2017-11-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • Effects of anesthesia on renal function and metabolism in rats assessed by hyperpolarized MRI.

    abstract:PURPOSE:Anesthesia is necessary for most animal studies requiring invasive procedures. It is well documented that various types of anesthesia modulate a wide variety of important metabolic and functional processes in the body, and as such, represent a potential limitation in the study design. In the present study, we a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27165

    authors: Qi H,Mariager CØ,Lindhardt J,Nielsen PM,Stødkilde-Jørgensen H,Laustsen C

    更新日期:2018-11-01 00:00:00

  • S5FP: spectrally selective suppression with steady state free precession.

    abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20633

    authors: Derbyshire JA,Herzka DA,McVeigh ER

    更新日期:2005-10-01 00:00:00

  • Direct reconstruction of MR images from data acquired on a non-Cartesian grid using an equal-phase-line algorithm.

    abstract::The equal-phase line (EPL) algorithm is proposed as a means of allowing rapid Fourier transform (FT) reconstruction of MR image data acquired on a non-Cartesian grid. The pixels on the image are grouped according to their positions. The pixels in a group have the same phase in the complex exponential function -exp[j2p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10165

    authors: Qian Y,Lin J,Jin D

    更新日期:2002-06-01 00:00:00

  • Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers.

    abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25196

    authors: Kurz FT,Kampf T,Heiland S,Bendszus M,Schlemmer HP,Ziener CH

    更新日期:2014-05-01 00:00:00

  • Present clinical status of magnetic resonance imaging.

    abstract::Magnetic resonance imaging has achieved clinical importance and has become the primary tool in the investigation of head, spinal cord, pelvis, cancellous bone, pericardium (with gating), gallbladder, lymph node masses, and very soon, in the evaluation of joints. In many areas, particularly with respiratory and ECG gat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910020402

    authors: Margulis AR,Fisher MR

    更新日期:1985-08-01 00:00:00

  • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

    abstract::Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20615

    authors: Markl M,Leupold J,Bieri O,Scheffler K,Hennig J

    更新日期:2005-10-01 00:00:00