Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

Abstract:

PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calculate the magnitude and phase of the transverse magnetization across the slice profile. Additionally, regional variations of the transmit RF field and slice profile scaling due to macroscopic field gradients were included. Simulations, phantom, and in vivo measurements at 3 T were conducted for R 2 ∗ and myelin water fraction (MWF) mapping. RESULTS:The influence of macroscopic field gradients on R 2 ∗ and myelin water fraction estimation can be substantially reduced by applying the proposed model. Moreover, it was shown that the dephasing over time for flip angles of 60° or greater also depends on the polarity of the slice-selection gradient because of phase variation along the slice profile. CONCLUSION:Substantial improvements in R 2 ∗ accuracy and myelin water fraction mapping coverage can be achieved using the proposed model if higher flip angles are required. In this context, we demonstrated that the phase along the slice profile and the polarity of the slice-selection gradient are essential for proper modeling of the gradient-echo signal in the presence of macroscopic field variations.

journal_name

Magn Reson Med

authors

Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

doi

10.1002/mrm.28139

subject

Has Abstract

pub_date

2020-08-01 00:00:00

pages

620-633

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

84

pub_type

杂志文章
  • The importance of correcting for signal drift in diffusion MRI.

    abstract:PURPOSE:To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS:We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26124

    authors: Vos SB,Tax CM,Luijten PR,Ourselin S,Leemans A,Froeling M

    更新日期:2017-01-01 00:00:00

  • Simultaneous assessment of cardiac metabolism and perfusion using copolarized [1-13 C]pyruvate and 13 C-urea.

    abstract:PURPOSE:To demonstrate the feasibility of imaging a bolus of co-polarized [1-13 C]pyruvate and 13 C-urea to simultaneously assess both metabolism and perfusion in the rodent heart. METHODS:Copolarized [1-13 C]pyruvate and 13 C-urea was imaged using a multi-echo, flow-sensitized spiral pulse sequence. Healthy rats were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26106

    authors: Lau AZ,Miller JJ,Robson MD,Tyler DJ

    更新日期:2017-01-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

    abstract::Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21728

    authors: Robson PM,Grant AK,Madhuranthakam AJ,Lattanzi R,Sodickson DK,McKenzie CA

    更新日期:2008-10-01 00:00:00

  • Three-dimensional MRI with an undersampled spherical shells trajectory.

    abstract::The shells trajectory is a 3D data acquisition method with improved efficiency compared to Cartesian sampling. It is a true center-out trajectory that does not repeatedly resample the center of k-space, and also offers advantages for motion correction. This work demonstrates that k-space undersampling can be combined ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20977

    authors: Shu Y,Riederer SJ,Bernstein MA

    更新日期:2006-09-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Echo-planar time course MRI of cat brain oxygenation changes.

    abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220117

    authors: Turner R,Le Bihan D,Moonen CT,Despres D,Frank J

    更新日期:1991-11-01 00:00:00

  • Cerebrospinal fluid pulse wave velocity measurements: In vitro and in vivo evaluation of a novel multiband cine phase-contrast MRI sequence.

    abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28430

    authors: Sonnabend K,Brinker G,Maintz D,Bunck AC,Weiss K

    更新日期:2021-01-01 00:00:00

  • Q-space truncation and sampling in diffusion spectrum imaging.

    abstract:PURPOSE:To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS:DSI data were acquired using the MGH-USC connectome scanner (Gmax  = 300 mT/m) with bmax  = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 gri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26071

    authors: Tian Q,Rokem A,Folkerth RD,Nummenmaa A,Fan Q,Edlow BL,McNab JA

    更新日期:2016-12-01 00:00:00

  • NMR quantification of lactate production and efflux and glutamate fractional enrichment in living human prostate biopsies cultured with [1,6-13 C2 ]glucose.

    abstract:PURPOSE:Image-guided prostate biopsies are routinely acquired in the diagnosis and treatment monitoring of prostate cancer, yielding useful tissue for identifying metabolic biomarkers and therapeutic targets. We developed an optimized biopsy tissue culture protocol in combination with [1,6-13 C2 ]glucose labeling and q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27739

    authors: Bancroft Brown J,Sriram R,VanCriekinge M,Delos Santos R,Sun J,Delos Santos J,Tabatabai ZL,Shinohara K,Nguyen H,Peehl DM,Kurhanewicz J

    更新日期:2019-08-01 00:00:00

  • Decomposed direct matrix inversion for fast non-cartesian SENSE reconstructions.

    abstract::A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20974

    authors: Qian Y,Zhang Z,Wang Y,Boada FE

    更新日期:2006-08-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • In vivo GABA editing using a novel doubly selective multiple quantum filter.

    abstract::A novel multiple quantum filtering method is proposed that uses a doubly selective pulse termed Delays Alternating with Nutations for Tailored Excitation (DANTE) for multiple quantum preparation. This method selectively prepares GABA-3 and GABA-4 into a multiple quantum state and suppresses all other resonances at 3.0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10104

    authors: Shen J,Rothman DL,Brown P

    更新日期:2002-03-01 00:00:00

  • Tumor 31P NMR pH measurements in vivo: a comparison of inorganic phosphate and intracellular 2-deoxyglucose-6-phosphate as pHnmr indicators in murine radiation-induced fibrosarcoma-1.

    abstract::Uncertainty regarding the intracellular/extracellular distribution of inorganic phosphate (P(i)) in tumors has raised concerns that pH calculated from the tumor P(i) chemical shift may not accurately represent the intracellular pH (pHin). This issue was addressed in subcutaneously transplanted murine radiation induced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360508

    authors: Soto GE,Zhu Z,Evelhoch JL,Ackerman JJ

    更新日期:1996-11-01 00:00:00

  • The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    abstract::Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surroun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23235

    authors: Langman DA,Goldberg IB,Judy J,Paul Finn J,Ennis DB

    更新日期:2012-08-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • Measurement of changes in cerebral blood volume in spontaneously hypertensive rats following L-arginine infusion using dynamic susceptibility contrast MRI.

    abstract::To understand whether the NO-dependent vasodilator L-arginine was effective upon a chronically hypertensive cerebral capillary endothelium, dynamic susceptibility contrast MRI was used to measure the relative cerebral blood volume (rCBV) changes in nonischemic spontaneously hypertensive rats (SHRs). rCBV was measured ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390123

    authors: Caramia F,Yoshida T,Hamberg LM,Huang Z,Hunter G,Wanke I,Zaharchuk G,Moskowitz MA,Rosen BR

    更新日期:1998-01-01 00:00:00

  • Volume-localized measurement of oxygen extraction fraction in the brain using MRI.

    abstract:PURPOSE:T2 -relaxation-under-spin-tagging (TRUST) is an MR technique for the non-invasive assessment of whole-brain cerebral oxygen extraction fraction (OEF), through measurement of the venous blood T2 relaxation time in the sagittal sinus. A key limitation of TRUST, however, is the lack of spatial specificity of the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27823

    authors: O'Brien C,Okell TW,Chiew M,Jezzard P

    更新日期:2019-10-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Experimental approaches to image localized human 31P NMR spectroscopy.

    abstract::Experimental procedures for obtaining localized 31P NMR spectra of humans by means of the ISIS sequence are discussed in detail. The technique is optimized for use with volume coils and with surface coils in order to measure localized 31P NMR spectra of different tissues and organs. Selective frequency-modulated (FM) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110102

    authors: Luyten PR,Groen JP,Vermeulen JW,den Hollander JA

    更新日期:1989-07-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • Dynamic 13C NMR analysis of pyruvate and lactate oxidation in the in vivo canine myocardium: evidence of reduced utilization with increased work.

    abstract::In this work, substrate selection was monitored in the left ventricle of the canine myocardium by following pyruvate and lactate oxidation under in vivo conditions at basal and elevated workloads. These studies were conducted in the open chest model using dynamic 13C NMR techniques in the presence and absence of dichl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380608

    authors: Rath DP,Zhu H,Tong X,Jiang Z,Hamlin RL,Robitaille PM

    更新日期:1997-12-01 00:00:00

  • NMR dispersion investigations of enzymatically degraded bovine articular cartilage.

    abstract:PURPOSE:Cross-relaxation of protons with (14) N nuclei in proteins enhances relaxivity in the quadrupolar dip range of typically 2-3 MHz Larmor frequency. The magnitude of these dips was suggested as a means of assessing the degeneracy of articular cartilage during osteoarthritis (OA). However, so far only proteoglycan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25292

    authors: Rössler E,Mattea C,Stapf S

    更新日期:2015-05-01 00:00:00

  • The sensitivity of low flip angle RARE imaging.

    abstract::It is demonstrated that the stability of the Carr-Purcell-Meiboom-Gill (CPMG) sequence reflects the existence of a steady state solution to the Bloch equations in the absence of T2 and T1 decay. The steady state theory is then used to evaluate the performance of low flip angle RARE imaging sequences with both constant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370206

    authors: Alsop DC

    更新日期:1997-02-01 00:00:00

  • Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain.

    abstract:PURPOSE:Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues by means of the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28083

    authors: Arbabi A,Kai J,Khan AR,Baron CA

    更新日期:2020-06-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • Model-free arterial spin labeling quantification approach for perfusion MRI.

    abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20784

    authors: Petersen ET,Lim T,Golay X

    更新日期:2006-02-01 00:00:00

  • In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles.

    abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330209

    authors: Yeh TC,Zhang W,Ildstad ST,Ho C

    更新日期:1995-02-01 00:00:00