Measurement of changes in cerebral blood volume in spontaneously hypertensive rats following L-arginine infusion using dynamic susceptibility contrast MRI.

Abstract:

:To understand whether the NO-dependent vasodilator L-arginine was effective upon a chronically hypertensive cerebral capillary endothelium, dynamic susceptibility contrast MRI was used to measure the relative cerebral blood volume (rCBV) changes in nonischemic spontaneously hypertensive rats (SHRs). rCBV was measured in 11 rats at 4.7 T using fast gradient echo imaging with intravenous injection of Gd-DTPA. Images were acquired before, immediately after, and up to 90 min after the infusion of 300 mg/kg L-arginine (n = 7) or of an equivalent volume of saline (n = 4). L-arginine increased rCBV in cortex beginning 10 min after infusion and reached significance after 30 min (P < 0.01), reached a peak of 1.24 +/- 0.06 (mean +/- SEM) times pre-injection level after 50 min, and was sustained throughout the 90 min observation period. In contrast, the rCBV in the deeper gray matter (striatum) showed no statistically significant change over the 90 min observation period. While this is consistent with previous studies showing that L-arginine infusion can directly modulate vascular tone and cerebral hemodynamics, it demonstrates that the effect is present only in cortex, and that it can occur also in the setting of a disturbed capillary endothelium.

journal_name

Magn Reson Med

authors

Caramia F,Yoshida T,Hamberg LM,Huang Z,Hunter G,Wanke I,Zaharchuk G,Moskowitz MA,Rosen BR

doi

10.1002/mrm.1910390123

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

160-3

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

39

pub_type

杂志文章
  • Quantitative transport mapping (QTM) of the kidney with an approximate microvascular network.

    abstract:PURPOSE:Proof-of-concept study of mapping renal blood flow vector field according to the inverse solution to a mass transport model of time resolved tracer-labeled MRI data. THEORY AND METHODS:To determine tissue perfusion according to the underlying physics of spatiotemporal tracer concentration variation, the mass t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28584

    authors: Zhou L,Zhang Q,Spincemaille P,Nguyen TD,Morgan J,Dai W,Li Y,Gupta A,Prince MR,Wang Y

    更新日期:2021-04-01 00:00:00

  • Multi-turn transmit coil to increase b1 efficiency in current source amplification.

    abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24612

    authors: Gudino N,Griswold MA

    更新日期:2013-04-01 00:00:00

  • Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

    abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24137

    authors: Song T,Stainsby JA,Ho VB,Hood MN,Slavin GS

    更新日期:2012-03-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations.

    abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26333

    authors: McGrath DM,Ravikumar N,Beltrachini L,Wilkinson ID,Frangi AF,Taylor ZA

    更新日期:2017-07-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

    abstract::We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by opti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320416

    authors: Felblinger J,Lehmann C,Boesch C

    更新日期:1994-10-01 00:00:00

  • Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

    abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>

    authors: Afeworki M,van Dam GM,Devasahayam N,Murugesan R,Cook J,Coffin D,Larsen JH,Mitchell JB,Subramanian S,Krishna MC

    更新日期:2000-03-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI.

    abstract::Fluid-attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by T1 changes induced by paramagnetic molecular oxygen. Previous studies demonstrated a linear relationship between t...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20546

    authors: Zaharchuk G,Martin AJ,Rosenthal G,Manley GT,Dillon WP

    更新日期:2005-07-01 00:00:00

  • The importance of correcting for signal drift in diffusion MRI.

    abstract:PURPOSE:To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS:We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26124

    authors: Vos SB,Tax CM,Luijten PR,Ourselin S,Leemans A,Froeling M

    更新日期:2017-01-01 00:00:00

  • Exploring the limits of RF shimming for high-field MRI of the human head.

    abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21013

    authors: Mao W,Smith MB,Collins CM

    更新日期:2006-10-01 00:00:00

  • Novel RF coil geometry for lower extremity imaging.

    abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10712

    authors: Brown R,Mareyam A,Reid E,Wang Y

    更新日期:2004-03-01 00:00:00

  • Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

    abstract:PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25646

    authors: Deniz CM,Vaidya MV,Sodickson DK,Lattanzi R

    更新日期:2016-01-01 00:00:00

  • On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments.

    abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290510

    authors: Neil JJ,Bretthorst GL

    更新日期:1993-05-01 00:00:00

  • MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis.

    abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1252

    authors: Pathak AP,Schmainda KM,Ward BD,Linderman JR,Rebro KJ,Greene AS

    更新日期:2001-10-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Catheter tracking using continuous radial MRI.

    abstract::The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370623

    authors: Rasche V,Holz D,Köhler J,Proksa R,Röschmann P

    更新日期:1997-06-01 00:00:00

  • Real-time cardiovascular MR with spatio-temporal artifact suppression using deep learning-proof of concept in congenital heart disease.

    abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27480

    authors: Hauptmann A,Arridge S,Lucka F,Muthurangu V,Steeden JA

    更新日期:2019-02-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: dose-dependent and temporal evolution of T1 contrast.

    abstract::Manganese is a useful contrast agent for MRI of animals. Previously, it has been shown that systemic doses of MnCl(2) provide unique contrast in the rodent brain, enabling visualization of neuroarchitecture. The present work investigates the dose and temporal dependence of brain enhancement after i.v. administration o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20368

    authors: Lee JH,Silva AC,Merkle H,Koretsky AP

    更新日期:2005-03-01 00:00:00

  • Joint image reconstruction and sensitivity estimation in SENSE (JSENSE).

    abstract::Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21245

    authors: Ying L,Sheng J

    更新日期:2007-06-01 00:00:00

  • Editing through multiple bonds: threonine detection.

    abstract::In in vivo (1)H spectroscopy, the signal at 1.32 ppm is usually assigned to lactate. This resonance position is shared with threonine at physiological pH. The similarity of spectral patterns of lactate and threonine renders the separate measurement of either threonine or lactate without and even with editing technical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21492

    authors: Marjanska M,Henry PG,Uğurbil K,Gruetter R

    更新日期:2008-02-01 00:00:00

  • In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques.

    abstract::A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear pol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10392

    authors: Foster MA,Grigor'ev IA,Lurie DJ,Khramtsov VV,McCallum S,Panagiotelis I,Hutchison JM,Koptioug A,Nicholson I

    更新日期:2003-03-01 00:00:00

  • Fast 1H spectroscopic imaging using a multi-element head-coil array.

    abstract::Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to inc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400204

    authors: Schäffter T,Börnert P,Leussler C,Carlsen IC,Leibfritz D

    更新日期:1998-08-01 00:00:00

  • Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging.

    abstract::Amide proton transfer imaging, a specific form of chemical exchange saturation transfer imaging, has previously been applied to studies of acute ischemic acidosis, stroke, and cancer. However, interpreting the resulting contrast is complicated by its dependence on the exchange rate between amides and water, the amide ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23276

    authors: Zu Z,Janve VA,Li K,Does MD,Gore JC,Gochberg DF

    更新日期:2012-09-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • pH mapping in living tissues: an application of in vivo 31P NMR chemical shift imaging.

    abstract::Chemical shifts were extracted from in vivo 3-dimensional 31P NMR CSI data and pH images were constructed. The images could spatially resolve tissue pH ranging from 5.8 to 7.2 (with uncertainty of 0.11-0.17 pH unit) in an ischemia-reperfusion model of diabetic rat calf muscles. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290214

    authors: Morikawa S,Inubushi T,Kito K,Kido C

    更新日期:1993-02-01 00:00:00

  • Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

    abstract::When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21959

    authors: McGrath DM,Bradley DP,Tessier JL,Lacey T,Taylor CJ,Parker GJ

    更新日期:2009-05-01 00:00:00

  • Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

    abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25785

    authors: Xie Y,Yang Q,Xie G,Pang J,Fan Z,Li D

    更新日期:2016-06-01 00:00:00