Fast 1H spectroscopic imaging using a multi-element head-coil array.

Abstract:

:Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to increase the signal-to-noise ratio (SNR) of MRSI in the human brain. The flexible wraparound design optimally fits different head sizes and thus provides high sensitivity. The signal combination of the individual coil elements is based on the approach proposed by Roemer et al. (Magn. Reson. Med. 16, 192 (1990)). An additional short prescan is performed to provide a good estimate of the complex coil sensitivity profiles, which are used in the signal combination procedure to correct the spectroscopic imaging data for the spatially varying intensity. The use of coil arrays in MRSI has some effect on the requirements for both water and lipid suppression. These techniques and a MRSI pulse sequence that provides a high spectroscopic resolution are described and discussed. Experimental results at 1.5 T show that metabolite maps of N-acetylaspartate (NAA), choline (Cho), phosphocreatine (PCr)/creatine (Cr) can be obtained within a 5-min acquisition time.

journal_name

Magn Reson Med

authors

Schäffter T,Börnert P,Leussler C,Carlsen IC,Leibfritz D

doi

10.1002/mrm.1910400204

subject

Has Abstract

pub_date

1998-08-01 00:00:00

pages

185-93

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

40

pub_type

杂志文章
  • Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

    abstract::An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal res...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1126

    authors: Panych LP,Zhao L,Jolesz FA,Mulkern RV

    更新日期:2001-06-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Coaxial waveguide for travelling wave MRI at ultrahigh fields.

    abstract::At high magnetic fields the performance of a volume-type body coil inside a human sized MR-scanner is influenced by the waveguide action of the scanner's bore. This can result in undesirable strong radio frequency fields B1+) outside the coil's target volume. A radio frequency (RF) transmit system, exploiting this wav...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24496

    authors: Andreychenko A,Kroeze H,Klomp DW,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2013-09-01 00:00:00

  • Conversion of arterial input functions for dual pharmacokinetic modeling using Gd-DTPA/MRI and 18F-FDG/PET.

    abstract::Reaching the full potential of magnetic resonance imaging (MRI)-positron emission tomography (PET) dual modality systems requires new methodologies in quantitative image analyses. In this study, methods are proposed to convert an arterial input function (AIF) derived from gadolinium-diethylenetriaminepentaacetic acid ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24318

    authors: Poulin E,Lebel R,Croteau E,Blanchette M,Tremblay L,Lecomte R,Bentourkia M,Lepage M

    更新日期:2013-03-01 00:00:00

  • An analytical solution for the SSFP signal in MRI.

    abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10410

    authors: Hänicke W,Vogel HU

    更新日期:2003-04-01 00:00:00

  • Investigation of a whole-body receiver coil operating at liquid nitrogen temperatures.

    abstract::This communication describes the design and application of a receiver coil operating at liquid nitrogen temperature and intended as a surface coil in a whole-body imager. Its particular application is seen as the external receiver for parasitic internal or implanted detectors. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070211

    authors: Hall AS,Barnard B,McArthur P,Gilderdale DJ,Young IR,Bydder GM

    更新日期:1988-06-01 00:00:00

  • Ultra-rapid gradient echo imaging.

    abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330123

    authors: Heid O,Deimling M,Huk WJ

    更新日期:1995-01-01 00:00:00

  • Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling.

    abstract::MR images acquired by using an arterial spin-labeling technique showed spatial and temporal variations of perfusion in the skeletal muscle of exercising humans. Perfusion measurements made during plantar flexion exercise in normal volunteers were consistent with those obtained by traditional techniques reported in the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>

    authors: Frank LR,Wong EC,Haseler LJ,Buxton RB

    更新日期:1999-08-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease.

    abstract::Given its greater availability and lower cost, (129) Xe apparent diffusion coefficient (ADC) MRI offers an alternative to (3) He ADC MRI. To demonstrate the feasibility of hyperpolarized (129) Xe ADC MRI, we present results from healthy volunteers (HV), chronic obstructive pulmonary disease (COPD) subjects, and age-ma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22697

    authors: Kaushik SS,Cleveland ZI,Cofer GP,Metz G,Beaver D,Nouls J,Kraft M,Auffermann W,Wolber J,McAdams HP,Driehuys B

    更新日期:2011-04-01 00:00:00

  • Phase contrast MRI with flow compensation view sharing.

    abstract:PURPOSE:To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS:PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25133

    authors: Wang D,Shao J,Rapacchi S,Middione MJ,Ennis DB,Hu P

    更新日期:2015-02-01 00:00:00

  • Generalization of intravoxel incoherent motion model by introducing the notion of continuous pseudodiffusion variable.

    abstract:PURPOSE:A generalized intravoxel incoherent motion (IVIM) model, called the GIVIM, was proposed to better account for complex perfusion present in the tissues having various vessels and flow regimes, such as the liver. THEORY AND METHODS:The notions of continuous pseudodiffusion variable as well as perfusion fraction ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26064

    authors: Kuai ZX,Liu WY,Zhang YL,Zhu YM

    更新日期:2016-11-01 00:00:00

  • Metabolic response of the human heart to inotropic stimulation: in vivo phosphorus-31 studies of normal and cardiomyopathic myocardium.

    abstract::In order to determine if an increase in myocardial oxygen consumption is accompanied by changes in high energy phosphates in normal subjects and patients with dilated cardiomyopathy, phosphorus-31 spectra were acquired under resting conditions and during dobutamine infusion. In seven normal subjects, dobutamine raised...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250205

    authors: Schaefer S,Schwartz GG,Steinman SK,Meyerhoff DJ,Massie BM,Weiner MW

    更新日期:1992-06-01 00:00:00

  • Composite MRA: statistical approach to generate an MR angiogram from multiple contrasts.

    abstract:PURPOSE:To develop a method to use information from multiple MRI contrasts to produce a composite angiogram with reduced sequence-specific artifacts and improved vessel depiction. METHODS:Bayesian posterior vessel probability was determined as a function of black blood (BB), contrast enhanced angiography (CE-MRA), and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27966

    authors: Kim D,Edjlali M,Turski P,Johnson KM

    更新日期:2020-03-01 00:00:00

  • Mapping of redox status in a brain-disease mouse model by three-dimensional EPR imaging.

    abstract::Electron paramagnetic resonance imaging using nitroxides is a powerful method for visualizing the redox status modulated by oxidative stress in vivo. Typically, however, data acquisition times have been too slow to obtain a sufficient number of projections for three-dimensional images, when using continuous wave-elect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22598

    authors: Fujii H,Sato-Akaba H,Kawanishi K,Hirata H

    更新日期:2011-01-01 00:00:00

  • Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans.

    abstract:PURPOSE:To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored. METHODS:Six healthy volunteers were scanned with...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27765

    authors: Zanette B,Santyr G

    更新日期:2019-09-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • Quantitative measurement of regional lung ventilation using 3He MRI.

    abstract::A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10206

    authors: Deninger AJ,Månsson S,Petersson JS,Pettersson G,Magnusson P,Svensson J,Fridlund B,Hansson G,Erjefeldt I,Wollmer P,Golman K

    更新日期:2002-08-01 00:00:00

  • Magnetization transfer contrast-suppressed imaging of amide proton transfer and relayed nuclear overhauser enhancement chemical exchange saturation transfer effects in the human brain at 7T.

    abstract:PURPOSE:To use the variable delay multipulse (VDMP) chemical exchange saturation transfer (CEST) approach to obtain clean amide proton transfer (APT) and relayed Nuclear Overhauser enhancement (rNOE) CEST images in the human brain by suppressing the conventional magnetization transfer contrast (MTC) and reducing the di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25990

    authors: Xu X,Yadav NN,Zeng H,Jones CK,Zhou J,van Zijl PC,Xu J

    更新日期:2016-01-01 00:00:00

  • 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25840

    authors: Oezerdem C,Winter L,Graessl A,Paul K,Els A,Weinberger O,Rieger J,Kuehne A,Dieringer M,Hezel F,Voit D,Frahm J,Niendorf T

    更新日期:2016-06-01 00:00:00

  • Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

    abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26116

    authors: Poulsen C,Wakeman DG,Atefi SR,Luu P,Konyn A,Bonmassar G

    更新日期:2017-02-01 00:00:00

  • Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.

    abstract::The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21168

    authors: Ishii M,Emami K,Kadlecek S,Petersson JS,Golman K,Vahdat V,Yu J,Cadman RV,MacDuffie-Woodburn J,Stephen M,Lipson DA,Rizi RR

    更新日期:2007-03-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.

    abstract::Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (AC...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22803

    authors: Bauer S,Markl M,Honal M,Jung BA

    更新日期:2011-08-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

    abstract::The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10509

    authors: Sampath S,Derbyshire JA,Atalar E,Osman NF,Prince JL

    更新日期:2003-07-01 00:00:00

  • Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

    abstract:PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25646

    authors: Deniz CM,Vaidya MV,Sodickson DK,Lattanzi R

    更新日期:2016-01-01 00:00:00

  • Precise relaxation time measurements of normal-appearing white matter in inflammatory central nervous system disease.

    abstract::Precise relaxation time (RT) measurements have been made, with a standard deviation of 3% for T1 and T2 in white matter in normal volunteers. This sets an upper limit to the instrumental random errors (imprecision). Achieving this precision requires careful adjustment and use of the imager. The wide variation in RTs s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110307

    authors: Miller DH,Johnson G,Tofts PS,MacManus D,McDonald WI

    更新日期:1989-09-01 00:00:00

  • Lateral geniculate activations can be detected using intersubject averaging and fMRI.

    abstract::Applications of fMRI in functional brain imaging are mainly confined to single subject designs, prohibiting the assessment of subject or group by condition interactions (i.e., differential activations) or areas of conjoint activation. In this paper a framework for fMRI group designs, using statistical parametric mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380502

    authors: Büchel C,Turner R,Friston K

    更新日期:1997-11-01 00:00:00