The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.

Abstract:

:Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (ACS) lines NACS, the reconstruction kernel size (bx×by), and the undersampling factor R. To evaluate their influence on the performance of generalized autocalibrating partially parallel acquisitions, two phantom data sets acquired with 12-channel and 32-channel receive coils and three in vivo measurements were analyzed. Reconstruction parameters were systematically varied between R=2-4, NACS=4-64, bx=1-9, and by=2-10 to characterize their influence on image quality and noise. A main aspect of the analysis was to optimize the parameter set with respect to the effectively achieved net image acceleration. Selecting the undersampling factor R as small as possible for a given net acceleration yielded the best result in a clear majority of cases. For all data sets and coil geometries, the optimal kernel sizes and number of ACS lines were similar for a chosen undersampling factor R. In summary, the number of ACS lines should not be chosen below NACS=10-16. A robust choice for the kernel size was bx=9 and by=2-4.

journal_name

Magn Reson Med

authors

Bauer S,Markl M,Honal M,Jung BA

doi

10.1002/mrm.22803

subject

Has Abstract

pub_date

2011-08-01 00:00:00

pages

402-9

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

66

pub_type

杂志文章
  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Simultaneous measurement of intracellular and extracellular oxygen concentrations using a nitroxide-liposome system.

    abstract::The concentration of oxygen within cells is important in many physiological and pathological processes, but such oxygen-dependent phenomena are generally studied as a function of the concentration of extracellular oxygen, due to a lack of suitable methods. Electron parmamagnetic resonance (EPR) oximetric techniques of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290105

    authors: Glockner JF,Norby SW,Swartz HM

    更新日期:1993-01-01 00:00:00

  • Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

    abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22809

    authors: Fluckiger JU,Schabel MC,DiBella EV

    更新日期:2011-08-01 00:00:00

  • Efficient sample density estimation by combining gridding and an optimized kernel.

    abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23041

    authors: Zwart NR,Johnson KO,Pipe JG

    更新日期:2012-03-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • Numerical simulations of carotid MRI quantify the accuracy in measuring atherosclerotic plaque components in vivo.

    abstract:PURPOSE:Atherosclerotic carotid plaques can be quantified in vivo by MRI. However, the accuracy in segmentation and quantification of components such as the thin fibrous cap (FC) and lipid-rich necrotic core (LRNC) remains unknown due to the lack of a submillimeter scale ground truth. METHODS:A novel approach was take...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24905

    authors: Nieuwstadt HA,Geraedts TR,Truijman MT,Kooi ME,van der Lugt A,van der Steen AF,Wentzel JJ,Breeuwer M,Gijsen FJ

    更新日期:2014-07-01 00:00:00

  • (3)He pO2 mapping is limited by delayed-ventilation and diffusion in chronic obstructive pulmonary disease.

    abstract:PURPOSE:Lung pO2 mapping with (3)He MRI assumes that the sources of signal decay with time during a breath-hold are radiofrequency depolarization and oxygen-dependent T1 relaxation, but the method is sensitive to other sources of spatio-temporal signal change such as diffusion. The purpose of this work was to assess th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24779

    authors: Marshall H,Parra-Robles J,Deppe MH,Lipson DA,Lawson R,Wild JM

    更新日期:2014-03-01 00:00:00

  • Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease.

    abstract:PURPOSE:Noninvasive imaging techniques that quantify renal tissue composition are needed to more accurately ascertain prognosis and monitor disease progression in polycystic kidney disease (PKD). Given the success of magnetization transfer (MT) imaging to characterize various tissue remodeling pathologies, it was teste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25701

    authors: Kline TL,Irazabal MV,Ebrahimi B,Hopp K,Udoji KN,Warner JD,Korfiatis P,Mishra PK,Macura SI,Venkatesh SK,Lerman LO,Harris PC,Torres VE,King BF,Erickson BJ

    更新日期:2016-04-01 00:00:00

  • Quantitative liver 31P magnetic resonance spectroscopy at 3T on a clinical scanner.

    abstract:PURPOSE:The aims of this study were (i) to establish a robust and fast method to quantify hepatocellular phosphorus compounds in molar concentration on a 3T clinical scanner, (ii) to evaluate its reproducibility, and (iii) to test its feasibility for a use in large cohort studies. METHOD:Proton-decoupled (31) P magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24835

    authors: Laufs A,Livingstone R,Nowotny B,Nowotny P,Wickrath F,Giani G,Bunke J,Roden M,Hwang JH

    更新日期:2014-05-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

    abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27971

    authors: Bagga P,Hariharan H,Wilson NE,Beer JC,Shinohara RT,Elliott MA,Baur JA,Marincola FM,Witschey WR,Haris M,Detre JA,Reddy R

    更新日期:2020-03-01 00:00:00

  • Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

    abstract::Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27742

    authors: Wilson M,Andronesi O,Barker PB,Bartha R,Bizzi A,Bolan PJ,Brindle KM,Choi IY,Cudalbu C,Dydak U,Emir UE,Gonzalez RG,Gruber S,Gruetter R,Gupta RK,Heerschap A,Henning A,Hetherington HP,Huppi PS,Hurd RE,Kantarci K,Ka

    更新日期:2019-08-01 00:00:00

  • Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

    abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27439

    authors: Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

    更新日期:2019-01-01 00:00:00

  • Quantifying tissue damage due to focused ultrasound heating observed by MRI.

    abstract::Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<321::aid-mrm16

    authors: Graham SJ,Chen L,Leitch M,Peters RD,Bronskill MJ,Foster FS,Henkelman RM,Plewes DB

    更新日期:1999-02-01 00:00:00

  • Improved myo-inositol detection through Carr-Purcell PRESS: a tool for more sensitive mild cognitive impairment diagnosis.

    abstract::A 3-T study is presented, comparing the ability of two (1) H spectroscopy pulse sequences, Carr-Purcell point resolved spectroscopy (CPRESS; TE = 45 msec), and conventional PRESS (TE = 35 msec), to separate between groups of 20 normal control (NC) and 20 mild cognitive impairment (MCI) subjects. Both sequences showed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22749

    authors: Hancu I,Gillen R,Cowan J,Zimmerman EA

    更新日期:2011-06-01 00:00:00

  • High resolution hyperpolarized 13 C MRSI using SPICE at 9.4T.

    abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27061

    authors: Lee H,Song JE,Shin J,Joe E,Joo CG,Choi YS,Song HT,Kim DH

    更新日期:2018-08-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • A hybrid method for more efficient channel-by-channel reconstruction with many channels.

    abstract::In MRI, imaging using receiving coil arrays with a large number of elements is an area of growing interest. With increasing channel numbers for parallel acquisition, longer reconstruction times have become a significant concern. Channel reduction techniques have been proposed to reduce the processing time of channel-b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23048

    authors: Huang F,Lin W,Duensing GR,Reykowski A

    更新日期:2012-03-01 00:00:00

  • In vivo 13C magnetic resonance spectroscopy of human brain on a clinical 3 T scanner using [2-13C]glucose infusion and low-power stochastic decoupling.

    abstract::This study presents the detection of [2-(13)C]glucose metabolism in the carboxylic/amide region in the human brain, and demonstrates that the cerebral metabolism of [2-(13)C]glucose can be studied in human subjects in the presence of severe hardware constraints of widely available 3 T clinical scanners and with low-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22044

    authors: Li S,Zhang Y,Wang S,Yang J,Ferraris Araneta M,Farris A,Johnson C,Fox S,Innis R,Shen J

    更新日期:2009-09-01 00:00:00

  • A ranking of diffusion MRI compartment models with in vivo human brain data.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) microstructure imaging provides a unique noninvasive probe into tissue microstructure. The technique relies on biophysically motivated mathematical models, relating microscopic tissue features to the magnetic resonance (MR) signal. This work aims to determine which com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25080

    authors: Ferizi U,Schneider T,Panagiotaki E,Nedjati-Gilani G,Zhang H,Wheeler-Kingshott CA,Alexander DC

    更新日期:2014-12-01 00:00:00

  • Cardiac tagging with breath-hold cine MRI.

    abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280214

    authors: McVeigh ER,Atalar E

    更新日期:1992-12-01 00:00:00

  • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

    abstract::Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21676

    authors: Helms G,Finsterbusch J,Weiskopf N,Dechent P

    更新日期:2008-09-01 00:00:00

  • Global and peak local specific absorption rate control on parallel transmit systems using k-means SAR compression model.

    abstract:PURPOSE:To improve the specific absorption rate (SAR) compression model capability in parallel transmission (pTx) MRI systems. METHODS:A k-means clustering method is proposed to group voxels with similar SAR behaviors in the scanned object, providing a controlled upper-bounded estimation of peak local SARs. This k-mea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28456

    authors: Mao X,Bari S,Love DJ,Rispoli JV

    更新日期:2021-02-01 00:00:00

  • A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

    abstract::Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imagin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22413

    authors: Adriany G,Auerbach EJ,Snyder CJ,Gözübüyük A,Moeller S,Ritter J,Van de Moortele PF,Vaughan T,Uğurbil K

    更新日期:2010-06-01 00:00:00

  • In vivo validation of MR pulse pressure measurement in an aortic flow model: preliminary results.

    abstract::MR imaging experiments were conducted to investigate the feasibility of estimating vascular pulse pressure waveforms from measurements of blood flow rates and vessel cross-sectional area. Blood flow waveforms were measured in the aorta's of three 25-30-kg pigs at multiple imaging sections using phase-contrast velocity...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380209

    authors: Urchuk SN,Fremes SE,Plewes DB

    更新日期:1997-08-01 00:00:00

  • On the use of double-quantum coherence from an AX3 system (protons in lactate) for spectral editing.

    abstract::The suppression of water signals in in vivo proton spectra by means of multiple-quantum filtering can be brought about in several ways. This communication exposes the shortcomings of using purely subtractive filtering techniques to observe signals from metabolites that contain proton couplings of the form AX3. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110314

    authors: Nosel W,Trimble LA,Shen JF,Allen PS

    更新日期:1989-09-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00