Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

Abstract:

PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascular permeability constants from DCE MRI were measured from Hs 766 T, MIA PaCa-2, and SU.86.86 pancreatic tumor models. We used each of these measurements as predictors for machine learning classifier algorithms. We also used principal component analysis to reduce the dimensionality of entire CEST spectra and DCE signal evolutions, which were then analyzed using classification methods. RESULTS:The T1 relaxation time constants, % CEST amplitudes at specific saturation frequencies, and the relative Ktrans and kep values from DCE MRI could not classify all three tumor types. However, the area under the curve from DCE signal evolutions could classify each tumor type. Principal component analysis was used to analyze the entire CEST spectrum and DCE signal evolutions, which predicted the correct tumor model with 87.5% and 85.1% accuracy, respectively. CONCLUSIONS:Machine learning applied to the entire CEST spectrum improved the classification of the three tumor models, relative to classifications that used % CEST values at single saturation frequencies. A similar improvement was not attained with machine learning applied to T1 relaxation times or DCE signal evolutions, relative to more simplistic analysis methods.

journal_name

Magn Reson Med

authors

Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

doi

10.1002/mrm.27439

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

594-601

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

81

pub_type

杂志文章
  • Highly accelerated submillimeter resolution 3D GRASE with controlled T 2 blurring in T 2 -weighted functional MRI at 7 Tesla: A feasibility study.

    abstract:PURPOSE:To achieve highly accelerated submillimeter resolution T 2 -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume sel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28589

    authors: Park S,Torrisi S,Townsend JD,Beckett A,Feinberg DA

    更新日期:2020-11-24 00:00:00

  • Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

    abstract::The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20541

    authors: Meara SJ,Barker GJ

    更新日期:2005-07-01 00:00:00

  • Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans.

    abstract:PURPOSE:To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored. METHODS:Six healthy volunteers were scanned with...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27765

    authors: Zanette B,Santyr G

    更新日期:2019-09-01 00:00:00

  • Gadodiamide T1 relaxivity in brain tissue in vivo is lower than in saline.

    abstract::In vivo measurements of gadodiamide (Gd-DTPA-BMA) T(1) relaxivity were performed at 4.7 T in injured and normal rat brains. Cerebral lesions were induced in nine rats by a localized freezing method. T(1) maps of the lesions were generated before and after injection of Gd-DTPA-BMA (0.1-0.6 mmol/kg). Samples of normal a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20336

    authors: Pickup S,Wood AK,Kundel HL

    更新日期:2005-01-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • High-resolution quantitative sodium imaging at 9.4 Tesla.

    abstract:PURPOSE:Investigation of the feasibility to perform high-resolution quantitative sodium imaging at 9.4 Tesla (T). METHODS:A proton patch antenna was combined with a sodium birdcage coil to provide a proton signal without compromising the efficiency of the X-nucleus coil. Sodium density weighted images with a nominal r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25096

    authors: Mirkes CC,Hoffmann J,Shajan G,Pohmann R,Scheffler K

    更新日期:2015-01-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging.

    abstract::It is well known that when compared to conventional spin-echo (CSE) imaging for equivalent effective echo times, fast spin-echo (FSE) imaging experiments yield higher signal intensities for coupled spin systems, such as that for lipid. One hypothesis put forth for this phenomenon is the removal of scalar coupling-base...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350409

    authors: Williamson DS,Mulken RV,Jakab PD,Jolesz FA

    更新日期:1996-04-01 00:00:00

  • An analytic expression for the ultimate intrinsic SNR in a uniform sphere.

    abstract:PURPOSE:The ultimate intrinsic signal-to-noise ratio (UISNR) is normally calculated using electrodynamic simulations with a complete basis of modes. Here, we provide an exact solution for the UISNR at the center of a dielectric sphere and assess how accurately this solution approximates UISNR away from the center. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27207

    authors: Lee HH,Sodickson DK,Lattanzi R

    更新日期:2018-11-01 00:00:00

  • Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging.

    abstract:PURPOSE:MUSSELS is a one-step iterative reconstruction method for multishot diffusion weighted (msDW) imaging. The current work presents an efficient implementation, termed IRLS MUSSELS, that enables faster reconstruction to enhance its utility for high-resolution diffusion MRI studies. METHODS:The recently proposed M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28090

    authors: Mani M,Aggarwal HK,Magnotta V,Jacob M

    更新日期:2020-06-01 00:00:00

  • Broadband slab selection with B1+ mitigation at 7T via parallel spectral-spatial excitation.

    abstract::Chemical shift imaging benefits from signal-to-noise ratio (SNR) and chemical shift dispersion increases at stronger main field such as 7 Tesla, but the associated shorter radiofrequency (RF) wavelengths encountered require B1+ mitigation over both the spatial field of view (FOV) and a specified spectral bandwidth. Th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21834

    authors: Setsompop K,Alagappan V,Gagoski BA,Potthast A,Hebrank F,Fontius U,Schmitt F,Wald LL,Adalsteinsson E

    更新日期:2009-02-01 00:00:00

  • In vivo and ex vivo MR imaging of slowly cycling melanoma cells.

    abstract::Slowly cycling cells are believed to play a critical role in tumor progression and metastatic dissemination. The goal of this study was to develop a method for in vivo detection of slowly cycling cells. To distinguish these cells from more rapidly proliferating cells that constitute the vast majority of cells in tumor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22917

    authors: Magnitsky S,Roesch A,Herlyn M,Glickson JD

    更新日期:2011-11-01 00:00:00

  • Metabolite and macromolecule T1 and T2 relaxation times in the rat brain in vivo at 17.2T.

    abstract:PURPOSE:To measure the T1 and T2 relaxation times of water, metabolites, and macromolecules in the rat brain in vivo at 17.2T and achieve absolute quantification of the neurochemical profile. Relaxation times were compared with values from the literature found at lower magnetic fields. METHODS:(1) H NMR spectra were m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25602

    authors: Lopez-Kolkovsky AL,Mériaux S,Boumezbeur F

    更新日期:2016-02-01 00:00:00

  • In vivo field-cycling relaxometry using an insert coil for magnetic field offset.

    abstract:PURPOSE:The T(1) of tissue has a strong dependence on the measurement magnetic field strength. T(1) -dispersion could be a useful contrast parameter, but is unavailable to clinical MR systems which operate at fixed magnetic field strength. The purpose of this work was to implement a removable insert magnet coil for fie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25040

    authors: Pine KJ,Goldie F,Lurie DJ

    更新日期:2014-11-01 00:00:00

  • Localized two-dimensional shift correlated spectroscopy in humans at 2 Tesla.

    abstract::A method for the acquisition of localized 2D shift-correlated spectra, based on the combination of the stimulated-echo volume-selection and gradient-enhanced COSY experiments, is described. The sequence can be modified to perform a number of localized experiments including HOHAHA and DQF-COSY. The method is demonstrat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320216

    authors: Brereton IM,Galloway GJ,Rose SE,Doddrell DM

    更新日期:1994-08-01 00:00:00

  • Recovery of the rodent brain after cardiac arrest: a functional MRI study.

    abstract::Recovery of the cerebral cortex after 10 min of cardiac arrest was studied in rat using noninvasive MRI techniques. The apparent diffusion coefficient (ADC) of brain water was imaged to document reversal of the metabolic impairment. Perfusion-weighted imaging and blood oxygen level dependent (BOLD) imaging were perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390516

    authors: Schmitz B,Bock C,Hoehn-Berlage M,Kerskens CM,Böttiger BW,Hossmann KA

    更新日期:1998-05-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Clinical prostate T2 quantification using magnetization-prepared spiral imaging.

    abstract::T(2) quantification may augment diagnostic T(2)-weighted imaging; to improve cancer detection via auto-segmentation of multi-parametric acquisitions and to potentiate longitudinal studies of prostate cancer. However, robust quantitative techniques are not generally accessible or refined for clinical translation. This ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22492

    authors: Foltz WD,Chopra S,Chung P,Bayley A,Catton C,Jaffray D,Wright GA,Haider MA,Ménard C

    更新日期:2010-10-01 00:00:00

  • Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field.

    abstract:PURPOSE:To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS:A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding wa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26263

    authors: Castets CR,Lefrançois W,Wecker D,Ribot EJ,Trotier AJ,Thiaudière E,Franconi JM,Miraux S

    更新日期:2017-05-01 00:00:00

  • Fast mapping of myocardial blood flow with MR first-pass perfusion imaging.

    abstract::Accurate and fast quantification of myocardial blood flow (MBF) with MR first-pass perfusion imaging techniques on a pixel-by-pixel basis remains difficult due to relatively long calculation times and noise-sensitive algorithms. In this study, Zierler's central volume principle was used to develop an algorithm for the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21559

    authors: Goldstein TA,Jerosch-Herold M,Misselwitz B,Zhang H,Gropler RJ,Zheng J

    更新日期:2008-06-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Compressed Sensing 3D-GRASE for faster High-Resolution MRI.

    abstract:PURPOSE:High-resolution three-dimensional (3D) structural MRI is useful for delineating complex or small structures of the body. However, it requires long acquisition times and high SAR, limiting its clinical use. The purpose of this work is to accelerate the acquisition of high-resolution images by combining compresse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27789

    authors: Cristobal-Huerta A,Poot DHJ,Vogel MW,Krestin GP,Hernandez-Tamames JA

    更新日期:2019-09-01 00:00:00

  • Self-calibrating parallel imaging with automatic coil sensitivity extraction.

    abstract::Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10087

    authors: McKenzie CA,Yeh EN,Ohliger MA,Price MD,Sodickson DK

    更新日期:2002-03-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • MRI assessment of coronary microvascular endothelial nitric oxide synthase function using myocardial T1 mapping.

    abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26870

    authors: Cui SX,Epstein FH

    更新日期:2018-04-01 00:00:00

  • Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping.

    abstract::An approach to efficiently measure three-dimensional velocity vector fields and turbulent kinetic energy of blood flow is presented. Multipoint phase-contrast imaging is used in combination with Bayesian analysis to map both mean and fluctuating velocities over a large dynamic range and for practically relevant signal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24370

    authors: Binter C,Knobloch V,Manka R,Sigfridsson A,Kozerke S

    更新日期:2013-05-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Magnetic field dependence of proton relaxation rates in tissue with added Mn2+: rabbit liver and kidney.

    abstract::Since contrast in magnetic resonance imaging (MRI) is so sensitive to the magnetic relaxation rates of tissue protons, the use of paramagnetic ions to alter contrast in a tissue-specific fashion is an alluring prospect. The influence of these ions on the proton relaxation rates in homogeneous solutions is known to var...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020206

    authors: Koenig SH,Brown RD 3rd,Goldstein EJ,Burnett KR,Wolf GL

    更新日期:1985-04-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章