Magnetic field dependence of proton relaxation rates in tissue with added Mn2+: rabbit liver and kidney.

Abstract:

:Since contrast in magnetic resonance imaging (MRI) is so sensitive to the magnetic relaxation rates of tissue protons, the use of paramagnetic ions to alter contrast in a tissue-specific fashion is an alluring prospect. The influence of these ions on the proton relaxation rates in homogeneous solutions is known to vary dramatically according to whether the ions are present as hydrated aquoions, in solute chelate, or immobilized in macromolecules. In tissue, there is the additional complication of access of water to the ions. In the present study, Mn2+ ions were introduced into rabbits both orally and intravenously in various chemical complexes. Accumulation of these ions in rabbit liver is demonstrated here, qualitatively, by MRI. The quantitation of the change in relaxation rates is investigated in excised samples of liver and kidney by study of the magnetic field dependence (dispersion) of the relaxation rates of the protons (NMRD profiles) of tissue water. Results are presented for several sets of experiments, including dose-response data for weakly chelated Mn2+ and time-response data for free and complexed Mn2+. The general findings are that, for liver, the response (the increment in the NMRD profile) is relatively rapid (less than 2 m); that it is relatively independent of how, or in what form, the Mn2+ is introduced; that it persists for several hours (at least); and that it saturates with increasing body load of Mn2+. Moreover, from the form of the NMRD profiles of liver, it is clear that the Mn2+ ions are bound irrotationally, perhaps to cell membrane, and, when introduced in chelated form, can become separated even from strongly associated chelate complexes. For kidney, the results are qualitatively similar, though different in detail.

journal_name

Magn Reson Med

authors

Koenig SH,Brown RD 3rd,Goldstein EJ,Burnett KR,Wolf GL

doi

10.1002/mrm.1910020206

subject

Has Abstract

pub_date

1985-04-01 00:00:00

pages

159-68

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

2

pub_type

杂志文章
  • Measurement of myocardial pH by saturation transfer in man.

    abstract::Myocardial pH has been shown in animal models to be a sensitive indicator of ischemia. In vivo measurement in humans using 31p magnetic resonance spectroscopy is complicated by the overlap of blood 2,3-diphosphoglycerate peaks with the P(i) peak used for pH measurement. A "saturation transfer" method combined with spa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<198::aid-mrm28

    authors: Blamire AM,Rajagopalan B,Radda GK

    更新日期:1999-01-01 00:00:00

  • Absolute quantification of myocardial perfusion under adenosine stress.

    abstract::The prebolus technique allows one to quantify perfusion in the human heart with a low variability by means of MRI. In this study the prebolus technique was used to determine quantitative perfusion values in the human heart under adenosine stress and to measure the myocardial perfusion reserve (MPR). Twelve healthy vol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21020

    authors: Ritter C,Brackertz A,Sandstede J,Beer M,Hahn D,Köstler H

    更新日期:2006-10-01 00:00:00

  • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

    abstract::Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400517

    authors: Jesmanowicz A,Bandettini PA,Hyde JS

    更新日期:1998-11-01 00:00:00

  • Off-resonance effects in the transient response of SSFP sequences.

    abstract::A previously developed eigenvector formalism is adapted to off-resonance in the transient response of quasiperiodic steady-state free precession (SSFP) sequences, including TrueFISP as a special case. The effective relaxation rates for essentially parallel and perpendicular deviations from the steady state are determi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20173

    authors: Ganter C

    更新日期:2004-08-01 00:00:00

  • Skeletal muscle ¹H MRSI before and after prolonged exercise. I. muscle specific depletion of intramyocellular lipids.

    abstract::Aim of the study was to determine distribution and depletion patterns of intramyocellular lipids (IMCL) in leg muscles before and after two types of standardized endurance exercise. ¹H-magnetic resonance spectroscopic imaging was performed (1) in the thigh of eight-trained cyclists after exercising on an ergometer for...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24168

    authors: Vermathen P,Saillen P,Boss A,Zehnder M,Boesch C

    更新日期:2012-11-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy.

    abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24129

    authors: Keating B,Ernst T

    更新日期:2012-11-01 00:00:00

  • NMR relaxometric investigation on human methemoglobin and fluoromethemoglobin. An improved quantitative in vitro assay of human methemoglobin.

    abstract::Longitudinal water proton relaxation rates of methemoglobin solutions show a strong dependence on temperature and pH. The increase of the relaxation rates with temperature is associated with shortened exchange lifetime of the coordinated water molecule. An accurate measurement of the relaxation rate of methemoglobin s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330613

    authors: Aime S,Fasano M,Paoletti S,Arnelli A,Ascenzi P

    更新日期:1995-06-01 00:00:00

  • Broadband proton decoupling for in vivo brain spectroscopy in humans.

    abstract::A new decoupling sequence, PBAR, is described for broadband heteronuclear decoupling in vivo in humans at 1.5T. The sequence uses non-adiabatic, frequency- and amplitude-modulated inversion pulses designed to minimize decoupling sidebands at low applied gammaB(2) RF field levels and to cover only the narrow range of r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200102)45:2<226::aid-mrm1031>3.0

    authors: Barker PB,Golay X,Artemov D,Ouwerkerk R,Smith MA,Shaka AJ

    更新日期:2001-02-01 00:00:00

  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00

  • Multifrequency reconstruction for frequency-modulated bSSFP.

    abstract:PURPOSE:Banding artifacts in images acquired by balanced steady-state free precession (bSSFP) remain a challenge in MRI as they considerably reduce image quality, and diagnostic value deteriorates accordingly. As the steady-state tolerates small shifts in frequency, it is possible to acquire frequency-modulated bSSFP. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26630

    authors: Slawig A,Wech T,Ratz V,Tran-Gia J,Neubauer H,Bley T,Köstler H

    更新日期:2017-12-01 00:00:00

  • Investigation of the early response to rat forepaw stimulation.

    abstract::The role of relative cerebral blood volume (rCBV) in the early response of blood oxygenation level-dependent (BOLD) signal following sensory stimulation was assessed. Magnetic resonance imaging (MRI) measurements of rCBV and BOLD signal as a function of time (t) were compared with relative cerebral blood flow (rCBF) o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<247::aid-mrm6>

    authors: Marota JJ,Ayata C,Moskowitz MA,Weisskoff RM,Rosen BR,Mandeville JB

    更新日期:1999-02-01 00:00:00

  • Kinetics of avidin-induced clearance of biotinylated bimodal liposomes for improved MR molecular imaging.

    abstract::Dual labeled liposomes, carrying both paramagnetic and fluorescent lipids, were recently proposed as potent contrast agents for MR molecular imaging. These nanoparticles are coated with poly(ethylene glycol) (PEG) to increase their blood circulation half-life, which should allow extensive accumulation at the targeted ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21780

    authors: van Tilborg GA,Strijkers GJ,Pouget EM,Reutelingsperger CP,Sommerdijk NA,Nicolay K,Mulder WJ

    更新日期:2008-12-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

    abstract::Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350306

    authors: Glover GH,Lemieux SK,Drangova M,Pauly JM

    更新日期:1996-03-01 00:00:00

  • Parallel reconstruction in accelerated multivoxel MR spectroscopy.

    abstract:PURPOSE:To develop the simultaneous acquisition of multiple voxels in localized MR spectroscopy (MRS) using sensitivity encoding, allowing reduced total scan time compared to conventional sequential single voxel (SV) acquisition methods. METHODS:Dual volume localization was used to simultaneously excite voxels in both...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25718

    authors: Boer VO,Klomp DW,Laterra J,Barker PB

    更新日期:2015-09-01 00:00:00

  • Perfusion imaging using dynamic arterial spin labeling (DASL).

    abstract::Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of the tissue, and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1136

    authors: Barbier EL,Silva AC,Kim SG,Koretsky AP

    更新日期:2001-06-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • Bayesian inference of hemodynamic changes in functional arterial spin labeling data.

    abstract::The study of brain function using MRI relies on acquisition techniques that are sensitive to different aspects of the hemodynamic response contiguous to areas of neuronal activity. For this purpose different contrasts such as arterial spin labeling (ASL) and blood oxygenation level dependent (BOLD) functional MRI tech...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21039

    authors: Woolrich MW,Chiarelli P,Gallichan D,Perthen J,Liu TT

    更新日期:2006-10-01 00:00:00

  • Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

    abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21345

    authors: Stalder AF,Elverfeldt DV,Paul D,Hennig J,Markl M

    更新日期:2008-01-01 00:00:00

  • NMR quantification of lactate production and efflux and glutamate fractional enrichment in living human prostate biopsies cultured with [1,6-13 C2 ]glucose.

    abstract:PURPOSE:Image-guided prostate biopsies are routinely acquired in the diagnosis and treatment monitoring of prostate cancer, yielding useful tissue for identifying metabolic biomarkers and therapeutic targets. We developed an optimized biopsy tissue culture protocol in combination with [1,6-13 C2 ]glucose labeling and q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27739

    authors: Bancroft Brown J,Sriram R,VanCriekinge M,Delos Santos R,Sun J,Delos Santos J,Tabatabai ZL,Shinohara K,Nguyen H,Peehl DM,Kurhanewicz J

    更新日期:2019-08-01 00:00:00

  • Simultaneous multi-site EPR spectroscopy in vivo.

    abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300210

    authors: Smirnov AI,Norby SW,Clarkson RB,Walczak T,Swartz HM

    更新日期:1993-08-01 00:00:00

  • Phosphorus-31 magnetic resonance spectroscopy in humans by spectroscopic imaging: localized spectroscopy and metabolite imaging.

    abstract::In in vivo phosphorus magnetic resonance spectroscopy (MRS), spectroscopic imaging (SI) can be used as a flexible localization technique, producing spectra from multiple volumes in a single examination. Presented here are phosphorus SI studies of human organs in which a selective-volume SI reconstruction was used rath...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120302

    authors: Twieg DB,Meyerhoff DJ,Hubesch B,Roth K,Sappey-Marinier D,Boska MD,Gober JR,Schaefer S,Weiner MW

    更新日期:1989-12-01 00:00:00

  • Comparison of prospective head motion correction with NMR field probes and an optical tracking system.

    abstract:PURPOSE:The aim of this study was to compare prospective head motion correction and motion tracking abilities of two tracking systems: Active NMR field probes and a Moiré phase tracking camera system using an optical marker. METHODS:Both tracking systems were used simultaneously on human subjects. The prospective head...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27343

    authors: Eschelbach M,Aghaeifar A,Bause J,Handwerker J,Anders J,Engel EM,Thielscher A,Scheffler K

    更新日期:2019-01-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • Detection of myocardial infarction in the mini-pig using NMR imaging.

    abstract::Spin-echo images of 10 myocardial infarcts in nine mini-pigs were obtained at 30 h, 3 days, and approximately 10 days postinfarction. Infarcts were not detected at all at 30 h in five out of five cases examined. At 3 days postembolization (six cases) one infarct was certainly detected, whilst at 10 days (nine cases) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050302

    authors: Checkley D,Loveday BE,Waterton JC,Zhu XP,Isherwood I

    更新日期:1987-09-01 00:00:00

  • Atraumatic quantitation of cerebral perfusion in cats by 19F magnetic resonance imaging.

    abstract::We have noninvasively produced low-resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2-ml voxels in eight cats. Typical signal-to-noise of 4 to 1 was obtained in cerebral voxels in 16.5-s epochs. Mean flow during normocapnia (paCO2 = 39 +/- 4 mm Hg) and hypercapnia (paCO2 = 62 +/- 4 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280105

    authors: Branch CA,Ewing JR,Helpern JA,Ordidge RJ,Butt S,Welch KM

    更新日期:1992-11-01 00:00:00

  • Segmented spin-echo pulses to increase fMRI signal: repeated intrinsic diffusional enhancement.

    abstract::Since its inception, functional magnetic resonance imaging (fMRI) has seen rapid progress in the application to neuroscience. Common gradient-recalled acquisition methods are susceptible to static field inhomogeneities, resulting in signal loss at the medial temporal area important for memory function or at the basal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<631::aid-mrm3>

    authors: Song AW,Mao H,Muthupillai R,Haist F,Dixon WT

    更新日期:1999-10-01 00:00:00