Metabolite and macromolecule T1 and T2 relaxation times in the rat brain in vivo at 17.2T.

Abstract:

PURPOSE:To measure the T1 and T2 relaxation times of water, metabolites, and macromolecules in the rat brain in vivo at 17.2T and achieve absolute quantification of the neurochemical profile. Relaxation times were compared with values from the literature found at lower magnetic fields. METHODS:(1) H NMR spectra were measured using a LASER localization sequence. T1 - and T2 -weighted spectra were analyzed using LCModel with an original parameterization of the macromolecule baseline. RESULTS:The T1 relaxation times of 20 metabolites and the T2 relaxation times of 16 singlets and J-coupled metabolites were measured. The mean T1 and T2 relaxation times for metabolites were 1721 ± 237 ms and 148 ± 53 ms, respectively. In addition, we measured the T1 and T2 relaxation times of 4 macromolecule resonance groups, their mean T1 and T2 relaxation times being 690 ± 100 ms and 37 ± 15 ms, respectively. Absolute quantification of 21 metabolites and 4 groups of macromolecule resonances was achieved with Cramer-Rao Lower Bounds below 5% for Cr, Gln, Glu, GPC, Ins, NAA, PCr, and Tau and below 25% for the remaining resonances. CONCLUSION:Comparison of our relaxation times to previously published values suggests a small increase of T1 values and a clear decrease of T2 values between 11.7 and 17.2T.

journal_name

Magn Reson Med

authors

Lopez-Kolkovsky AL,Mériaux S,Boumezbeur F

doi

10.1002/mrm.25602

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

503-14

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

75

pub_type

杂志文章
  • Functional imaging with FENSI: flow-enhanced signal intensity.

    abstract::Flow measurement methods for functional MRI (fMRI) are desirable as they are more closely tied to neuronal activity than the commonly used blood oxygenation techniques. In this work we introduce a flow-based functional imaging method. The method, called flow enhancement of signal intensity (FENSI), is an extension of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21325

    authors: Sutton BP,Ouyang C,Ching BL,Ciobanu L

    更新日期:2007-08-01 00:00:00

  • Robust 4D flow denoising using divergence-free wavelet transform.

    abstract:PURPOSE:To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS:DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25176

    authors: Ong F,Uecker M,Tariq U,Hsiao A,Alley MT,Vasanawala SS,Lustig M

    更新日期:2015-02-01 00:00:00

  • Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

    abstract::High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24176

    authors: Teeuwisse WM,Brink WM,Haines KN,Webb AG

    更新日期:2012-04-01 00:00:00

  • Perfusion-based event-related functional MRI.

    abstract::Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maxim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3

    authors: Liu HL,Gao JH

    更新日期:1999-12-01 00:00:00

  • Novel quadrature birdcage coil for a vertical B(0) field open MRI system.

    abstract::A birdcage coil possesses various intrinsic resonant modes. One of the modes produces sinusoidal current distribution around the rung elements of the birdcage and generates a highly uniform B(1) field in the transverse plane. Another mode is the end-ring resonant mode, in which there are no currents in the rungs of th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<633::aid-mrm18>3.0.c

    authors: Fujita H,Braum WO,Morich MA

    更新日期:2000-10-01 00:00:00

  • CEST MRI quantification procedures for breast cancer treatment-related lymphedema therapy evaluation.

    abstract:PURPOSE:To quantify chemical exchange saturation transfer contrast in upper extremities of participants with lymphedema before and after standardized lymphatic mobilization therapy using correction procedures for B0 and B1 heterogeneity, and T1 relaxation. METHODS:Females with (n = 12) and without (n = 17) breast canc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28031

    authors: Crescenzi R,Donahue PMC,Mahany H,Lants SK,Donahue MJ

    更新日期:2020-05-01 00:00:00

  • Bulk volume susceptibility difference between deoxyhemoglobin and oxyhemoglobin for HbA and HbS: A comparative study.

    abstract:PURPOSE:Sickle cell anemia is a blood disorder that alters the morphology and the oxygen affinity of the red blood cells. Cerebral oxygen extraction fraction measurements using quantitative BOLD contrast have been used for assessing inadequate oxygen delivery and the subsequent risk of ischemic stroke in sickle cell an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28668

    authors: Eldeniz C,Binkley MM,Fields M,Guilliams K,Ragan DK,Chen Y,Lee JM,Ford AL,An H

    更新日期:2021-01-21 00:00:00

  • A new design and rationale for 3D orthogonally oversampled k-space trajectories.

    abstract::A novel center-out 3D trajectory for sampling magnetic resonance data is presented. The trajectory set is based on a single Fermat spiral waveform, which is substantially undersampled in the center of k-space. Multiple trajectories are combined in a "stacked cone" configuration to give very uniform sampling throughout...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22918

    authors: Pipe JG,Zwart NR,Aboussouan EA,Robison RK,Devaraj A,Johnson KO

    更新日期:2011-11-01 00:00:00

  • Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement.

    abstract::Detre et al. (Magn. Reson. Med. 23, 37-45 (1992)) and Zhang et al., (Magn. Reson. Med. 25, 362 (1992)) have recently demonstrated a technique for the measurement of regional cerebral blood flow (rCBF) based on the continuous saturation (or inversion) of the arterial blood supply to the brain in rats at 4.7 T. In the w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310208

    authors: Walsh EG,Minematsu K,Leppo J,Moore SC

    更新日期:1994-02-01 00:00:00

  • Suppression of physiological eye movement artifacts in functional MRI using slab presaturation.

    abstract::Reduction of image-to-image signal fluctuations and imaging artifacts is important for fMRI studies. The imaging artifacts caused by respiration, cardiac pulsation, and gross head motion and the suppression of these artifacts have been studied for many years. However, the artifacts caused by eye movement and their eff...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380407

    authors: Chen W,Zhu XH

    更新日期:1997-10-01 00:00:00

  • Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26312

    authors: Huelnhagen T,Hezel F,Serradas Duarte T,Pohlmann A,Oezerdem C,Flemming B,Seeliger E,Prothmann M,Schulz-Menger J,Niendorf T

    更新日期:2017-06-01 00:00:00

  • Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

    abstract:PURPOSE:To develop a new parallel transmit (pTx) pulse design for simultaneous multiband (MB) excitation in order to tackle simultaneously the problems of transmit B1 (B1+) inhomogeneity and total radiofrequency (RF) power, so as to allow for optimal RF excitation when using MB pulses for slice acceleration for high an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24828

    authors: Wu X,Schmitter S,Auerbach EJ,Moeller S,Uğurbil K,Van de Moortele PF

    更新日期:2013-09-01 00:00:00

  • Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

    abstract:PURPOSE:To assess volumetric proton MR spectroscopic imaging (MRSI) of the human brain on multivendor MRI instruments. METHODS:Echo-planar spectroscopic imaging was developed on instruments from three manufacturers, with matched specifications and acquisition protocols that accounted for differences in sampling perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25510

    authors: Sabati M,Sheriff S,Gu M,Wei J,Zhu H,Barker PB,Spielman DM,Alger JR,Maudsley AA

    更新日期:2015-11-01 00:00:00

  • Prospective GIRF-based RF phase cycling to reduce eddy current-induced steady-state disruption in bSSFP imaging.

    abstract:PURPOSE:To propose an explicit Balanced steady-state free precession (bSSFP) signal model that predicts eddy current-induced steady-state disruptions and to provide a prospective, practical, and general eddy current compensation method. THEORY AND METHODS:Gradient impulse response functions (GIRF) were used to simulat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28097

    authors: Bruijnen T,Stemkens B,van den Berg CAT,Tijssen RHN

    更新日期:2020-07-01 00:00:00

  • Inability to directly detect magnetic field changes associated with neuronal activity.

    abstract::The ability to directly detect neuronal magnetic fields by MRI would help investigators achieve the "holy grail" of neuroimaging, namely both high spatial and temporal resolution. Both positive and negative findings have been reported in the literature, with no clear consensus as to the feasibility of direct detection...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21129

    authors: Parkes LM,de Lange FP,Fries P,Toni I,Norris DG

    更新日期:2007-02-01 00:00:00

  • Local specific absorption rate in brain tumors at 7 tesla.

    abstract:PURPOSE:MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25653

    authors: Restivo MC,van den Berg CA,van Lier AL,Polders DL,Raaijmakers AJ,Luijten PR,Hoogduin H

    更新日期:2016-01-01 00:00:00

  • Implementation of vascular-space-occupancy MRI at 7T.

    abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24334

    authors: Hua J,Jones CK,Qin Q,van Zijl PC

    更新日期:2013-04-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • Algorithms for extracting motion information from navigator echoes.

    abstract::Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360120

    authors: Wang Y,Grimm RC,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1996-07-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24440

    authors: Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim D

    更新日期:2013-07-01 00:00:00

  • Calcium-induced structural changes of cartilage proteoglycans studied by H NMR relaxometry and diffusion measurements.

    abstract::1H transverse nuclear magnetic relaxation times (T2) and self-diffusion coefficients (SDCs) of water were measured in isolated proteoglycan aggregates from pig articular cartilage. The influence of varying osmotic pressure, as well as of different calcium concentrations, on the samples was investigated. Due to a struc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<43::aid-mrm8>3

    authors: Werner A,Gründer W

    更新日期:1999-01-01 00:00:00

  • Model-free arterial spin labeling quantification approach for perfusion MRI.

    abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20784

    authors: Petersen ET,Lim T,Golay X

    更新日期:2006-02-01 00:00:00

  • Relative indices of water diffusion anisotropy are equivalent in live and formalin-fixed mouse brains.

    abstract::Formalin fixation of tissue is a common laboratory practice. A direct comparison of diffusion tensor imaging (DTI) parameters from mouse brains before (in vivo) and after (ex vivo) formalin fixation is reported herein. Five diffusion indices were examined in a cohort of seven mice: relative anisotropy (RA), directiona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10605

    authors: Sun SW,Neil JJ,Song SK

    更新日期:2003-10-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging.

    abstract:PURPOSE:The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS:Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25567

    authors: Song X,Xu J,Xia S,Yadav NN,Lal B,Laterra J,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2015-02-01 00:00:00

  • A continuum of T 2 * components: Flexible fast fraction mapping in sodium MRI.

    abstract:PURPOSE:Parameter mapping in sodium MRI data is challenging due to inherently low SNR and spatial resolution, prompting the need to employ robust models and estimation techniques. This work aims to develop a continuum model of sodium T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27659

    authors: Syeda W,Blunck Y,Kolbe S,Cleary JO,Johnston LA

    更新日期:2019-06-01 00:00:00

  • Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24114

    authors: Tam LK,Stockmann JP,Galiana G,Constable RT

    更新日期:2012-10-01 00:00:00

  • Factors influencing the accuracy and precision of velocity-encoded phase imaging.

    abstract::Velocity-encoded phase contrast imaging is being used increasingly in clinical imaging for quantization of blood flow. In this study, the accuracy and precision of ascending aorta flow measurements were found to depend on several subtle aspects of the scan prescription and image analysis. While the usual scan paramete...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260115

    authors: Buonocore MH,Bogren H

    更新日期:1992-07-01 00:00:00