Abstract:
PURPOSE:To propose an explicit Balanced steady-state free precession (bSSFP) signal model that predicts eddy current-induced steady-state disruptions and to provide a prospective, practical, and general eddy current compensation method. THEORY AND METHODS:Gradient impulse response functions (GIRF) were used to simulate trajectory-specific eddy current-induced phase errors at the end of a repetition block. These phase errors were included in bloch simulations to establish a bSSFP signal model to predict steady-state disruptions and their corresponding image artifacts. The signal model was embedded in the MR system and used to compensate the phase errors by prospectively modifying the phase cycling scheme of the RF pulse. The signal model and eddy current compensation method were validated in phantom and in vivo experiments. In addition, the signal model was used to analyze pre-existing eddy current mitigation methods, such as 2D tiny golden angle radial and 3D paired phase encoded Cartesian acquisitions. RESULTS:The signal model predicted eddy current-induced image artifacts, with the zeroth-order GIRF being the primary factor to predict the steady-state disruption. Prospective RF phase cycling schemes were automatically computed online and considerably reduced eddy current-induced image artifacts. The signal model provides a direct relationship for the smoothness of k-space trajectories, which explains the effectiveness of phase encode pairing and tiny golden angle trajectory. CONCLUSIONS:The proposed signal model can accurately predict eddy current-induced steady-state disruptions for bSSFP imaging. The signal model can be used to derive the eddy current-induced phase errors required for trajectory-specific RF phase cycling schemes, which considerably reduce eddy current-induced image artifacts.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Bruijnen T,Stemkens B,van den Berg CAT,Tijssen RHNdoi
10.1002/mrm.28097subject
Has Abstractpub_date
2020-07-01 00:00:00pages
115-127issue
1eissn
0740-3194issn
1522-2594journal_volume
84pub_type
杂志文章abstract::This study investigated the use of peritoneal dialysis fluid (dialyzate) as a MR contrast agent to visualize the liver structure and peritoneal adhesion in rats at 7 T. Intraperitoneal injection of dialyzate (approximately 0.1 ml/g) yielded excellent and consistent intraperitoneal enhancement that delineated the liver...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21506
更新日期:2008-05-01 00:00:00
abstract::The concept of temporal echo multiplexing is defined and used to develop rapid biphasic spin-echo sequences for imaging the heart. Three imaging sequences, based on four-echo and two-echo multiplexing and rapid single echo (i.e., conventional spin-echo imaging), are compared. Preliminary results indicate that two-echo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910110109
更新日期:1989-07-01 00:00:00
abstract::Hydrogen, sodium, and fluorine (added F-) NMR spectra of venous and oxygenated blood were measured. The fluorine resonance was seen as a single peak in both samples, and all three resonances exhibited the same deoxy-oxy shift. Because F- exchanges slowly across the red cell membrane, and because sodium is 95% extracel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910120210
更新日期:1989-11-01 00:00:00
abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20888
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS:Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were gen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26359
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:The purpose of this work was to develop and evaluate a robust water-fat separation method for T1-weighted symmetric two-point Dixon data. THEORY AND METHODS:A method for water-fat separation by phase unwrapping of the opposite-phase images by phase-sensitive reconstruction (PSR) is introduced. PSR consists of ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26488
更新日期:2017-09-01 00:00:00
abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22038
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Spatio-temporal encoding (SPEN) experiments can deliver single-scan MR images without folding complications and with robustness to chemical shift and susceptibility artifacts. Further resolution improvements are shown to arise by relying on multiple receivers, to interpolate the sampled data along the low-bandw...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26731
更新日期:2018-02-01 00:00:00
abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24112
更新日期:2012-10-01 00:00:00
abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22971
更新日期:2011-12-01 00:00:00
abstract::Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dep...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22962
更新日期:2011-12-01 00:00:00
abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0
更新日期:2001-03-01 00:00:00
abstract::Recent in vivo 1H MRS studies of muscle oxygen levels by means of myoglobin (Mb) oxygenation have necessitated an investigation of the possible contamination from deoxy-hemoglobin (Hb). To determine the contribution of Hb in these NMR measurements, we studied the NMR visibility of histidyl N-delta proton of Hb in lyse...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300616
更新日期:1993-12-01 00:00:00
abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910120106
更新日期:1989-10-01 00:00:00
abstract::Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recyc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330306
更新日期:1995-03-01 00:00:00
abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060311
更新日期:1988-03-01 00:00:00
abstract:PURPOSE:To develop a fast protocol for measuring T1 values in the internal carotid artery (ICA), to validate this technique with in vitro measurements, and to evaluate its reproducibility. METHODS:A modified Look-Locker sequence was optimized to enable rapid determination of T1 in the ICA at 3T. T1 values from the ICA...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26325
更新日期:2017-06-01 00:00:00
abstract::Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10653
更新日期:2003-12-01 00:00:00
abstract::A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20851
更新日期:2006-04-01 00:00:00
abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050313
更新日期:1987-09-01 00:00:00
abstract::Stimulated-echo localized spectroscopy was combined with phase- and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can be readily applie...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050412
更新日期:1987-10-01 00:00:00
abstract::Hyperpolarized 129Xe has been used to obtain gas phase images of mouse lung in vivo, showing distinct ventilation variation as a function of the breathing cycle. Spectra of 129Xe in the thorax show complex structure in both the gas phase (-4 to 3 ppm) and tissue-dissolved (190-205 ppm) regions. The alveolar gas peak s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360203
更新日期:1996-08-01 00:00:00
abstract::MRI of myocardial perfusion observed with an extracellular contrast agent has proven valuable for the detection of coronary artery disease. During contrast enhancement transient dark rim artifacts are sometimes visible, complicating diagnosis and quantification. In this work a quantification of the frequency offsets c...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.21723
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:To characterize the fundamental limits of MRI near metallic implants on RF excitation, frequency encoding, and chemical shift-encoding water-fat separation. METHODS:Multicomponent three-dimensional (3D) digital models of a total hip and a total knee replacement were used to construct material-specific suscepti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25540
更新日期:2015-12-01 00:00:00
abstract::Phase-contrast magnetic resonance imaging is subject to numerous sources of error, which decrease clinical confidence in the reported measures. This work outlines how stationary perivascular fat can impart a significant chemical shift induced phase-contrast magnetic resonance imaging measurement error using computatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24262
更新日期:2013-02-01 00:00:00
abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10133
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26818
更新日期:2018-03-01 00:00:00
abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330209
更新日期:1995-02-01 00:00:00
abstract::Diffusion tensor imaging (DTI) is a new imaging modality that can provide unique information on brain white matter anatomy. Measurements of water diffusion constant along multiple axes are fitted to a tensor model, from which the diffusion anisotropy and dominant fiber orientation can be estimated. Even though the ten...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20767
更新日期:2006-02-01 00:00:00
abstract::In guinea pigs immunized with myelin basic protein (MBP) in complete Freund's adjuvant, experimental allergic encephalomyelitis (EAE) shows a characteristic clinical and pathological course. This study characterized the proton nuclear magnetic resonance (NMR) properties of the central nervous system prior to the onset...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050203
更新日期:1987-08-01 00:00:00