Perfusion-based event-related functional MRI.

Abstract:

:Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maximum 4 sec later with a perfusion-sensitized signal change of 16. 1 +/- 2.6 %, and then decreases to baseline approximately 11 sec after the stimuli. As it is a more direct reflection of the hemodynamic response, perfusion-based event-related functional MRI techniques may be more useful for human cognitive function studies, compared with blood oxygenation level-dependent (BOLD)-based event-related functional MRI techniques. Magn Reson Med 42:1011-1013, 1999.

journal_name

Magn Reson Med

authors

Liu HL,Gao JH

doi

10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3

subject

Has Abstract

pub_date

1999-12-01 00:00:00

pages

1011-3

issue

6

eissn

0740-3194

issn

1522-2594

pii

10.1002/(SICI)1522-2594(199912)42:6<1011::AID-MRM3

journal_volume

42

pub_type

杂志文章
  • In vivo multiple-mouse MRI at 7 Tesla.

    abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20683

    authors: Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

    更新日期:2005-11-01 00:00:00

  • Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

    abstract:PURPOSE:To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS:A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image si...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24958

    authors: Chen D,Sharif B,Dharmakumar R,Thomson LE,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-09-01 00:00:00

  • Phase-contrast velocimetry with simultaneous fat/water separation.

    abstract::Phase-contrast MRI can provide high-resolution angiographic velocity images, especially in conjunction with non-Cartesian k-space sampling. However, acquisitions can be sensitive to errors from artifacts from main magnetic field inhomogeneities and chemical shift from fat. Particularly in body imaging, fat content can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22355

    authors: Johnson KM,Wieben O,Samsonov AA

    更新日期:2010-06-01 00:00:00

  • Quantifying tissue damage due to focused ultrasound heating observed by MRI.

    abstract::Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<321::aid-mrm16

    authors: Graham SJ,Chen L,Leitch M,Peters RD,Bronskill MJ,Foster FS,Henkelman RM,Plewes DB

    更新日期:1999-02-01 00:00:00

  • NMR quantification of lactate production and efflux and glutamate fractional enrichment in living human prostate biopsies cultured with [1,6-13 C2 ]glucose.

    abstract:PURPOSE:Image-guided prostate biopsies are routinely acquired in the diagnosis and treatment monitoring of prostate cancer, yielding useful tissue for identifying metabolic biomarkers and therapeutic targets. We developed an optimized biopsy tissue culture protocol in combination with [1,6-13 C2 ]glucose labeling and q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27739

    authors: Bancroft Brown J,Sriram R,VanCriekinge M,Delos Santos R,Sun J,Delos Santos J,Tabatabai ZL,Shinohara K,Nguyen H,Peehl DM,Kurhanewicz J

    更新日期:2019-08-01 00:00:00

  • Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

    abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25785

    authors: Xie Y,Yang Q,Xie G,Pang J,Fan Z,Li D

    更新日期:2016-06-01 00:00:00

  • Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND).

    abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26562

    authors: Zeng X,Barbic M,Chen L,Qian C

    更新日期:2017-11-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • Improved selectivity of double quantum coherence filtering for the detection of glutathione in the human brain in vivo.

    abstract::An improved double quantum coherence (DQC) filter for the selective in vivo detection of glutathione (GSH) in the human brain at 1.5 Tesla is presented. The goal was to minimize contamination of the DQC-filtered GSH signal at 2.9 ppm with contributions arising from GABA. The modification consists of tailoring the freq...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1094

    authors: Trabesinger AH,Boesiger P

    更新日期:2001-04-01 00:00:00

  • Carbon-13 "magic-angle" sample-spinning nuclear magnetic resonance studies of human myelin, and model membrane systems.

    abstract::We have obtained high-field (11.7 Tesla), high-resolution carbon-13 solid-state "magic-angle" sample-spinning nuclear magnetic resonance (NMR) spectra of a variety of phospholipids, sphingolipids, myelin and white matter samples, resolving and assigning over 40 resonances in the spectra of human and bovine myelin. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290204

    authors: Husted C,Montez B,Le C,Moscarello MA,Oldfield E

    更新日期:1993-02-01 00:00:00

  • 31P NMR spectroscopy of 9L cell line in culture: differential effects of high temperature on anchored cells and spheroids.

    abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190233

    authors: Suzuki N,Kwee IL,Tamas LB,Nakada T

    更新日期:1991-06-01 00:00:00

  • Simplified synthesis and relaxometry of magnetoferritin for magnetic resonance imaging.

    abstract::Magnetoferritin nanoparticles have been developed as high-relaxivity, functional contrast agents for MRI. Several previous techniques have relied on unloading native ferritin and re-incorporation of iron into the core, often resulting in a polydisperse sample. Here, a simplified technique is developed using commercial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22526

    authors: Jordan VC,Caplan MR,Bennett KM

    更新日期:2010-11-01 00:00:00

  • Single-shot, three-dimensional "non-echo" localization method for in vivo NMR spectroscopy.

    abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co

    authors: Choi IY,Tkác I,Gruetter R

    更新日期:2000-09-01 00:00:00

  • Deuterium magnetic resonance imaging of rabbit eye in vivo.

    abstract::We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330417

    authors: Obata T,Ikehira H,Koga M,Yoshida K,Kimura F,Tateno Y

    更新日期:1995-04-01 00:00:00

  • Robust motion correction in CEST imaging exploiting low-rank approximation of the z-spectrum.

    abstract:PURPOSE:To introduce and evaluate an image registration technique for robust quantification of CEST acquisitions corrupted by motion. METHODS:The proposed iterative algorithm exploits a low-rank approximation of the z-spectrum (LRAZ), to gradually separate the contrast variation due to saturation at different off-reso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27206

    authors: Wech T,Köstler H

    更新日期:2018-11-01 00:00:00

  • Quantitative susceptibility mapping using single-shot echo-planar imaging.

    abstract:PURPOSE:To perform quantitative susceptibility mapping (QSM) in negligible acquisition time and apply it to measuring iron-rich subcortical gray matter. METHODS:Whole brain QSM was performed using single-shot gradient echo-planar imaging (EPI) in under 7 seconds on a standard 1.5 T system for imaging brain iron in sub...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25316

    authors: Sun H,Wilman AH

    更新日期:2015-05-01 00:00:00

  • Multidimensionally encoded magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24443

    authors: Lin FH

    更新日期:2013-07-01 00:00:00

  • Restricted field of view magnetic resonance imaging of a dynamic time series.

    abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21115

    authors: Pisani L,Bammer R,Glover G

    更新日期:2007-02-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00

  • In vivo MR elastography of the prostate gland using a transurethral actuator.

    abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22038

    authors: Chopra R,Arani A,Huang Y,Musquera M,Wachsmuth J,Bronskill M,Plewes D

    更新日期:2009-09-01 00:00:00

  • Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

    abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21157

    authors: Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

    更新日期:2007-03-01 00:00:00

  • Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

    abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22234

    authors: Schär M,Vonken EJ,Stuber M

    更新日期:2010-02-01 00:00:00

  • In vivo 3.0-tesla magnetic resonance T1rho and T2 relaxation mapping in subjects with intervertebral disc degeneration and clinical symptoms.

    abstract::The purpose of this study is (1) to determine the correlation between T(1rho) and T(2) and degenerative grade in intervertebral discs using in vivo 3.0-T MRI, and (2) to determine the association between T(1rho) and T(2) and clinical findings as quantified by the SF-36 Questionnaire and Oswestry Disability Index. Sixt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22362

    authors: Blumenkrantz G,Zuo J,Li X,Kornak J,Link TM,Majumdar S

    更新日期:2010-05-01 00:00:00

  • On consideration of radiated power in RF field simulations for MRI.

    abstract::In numerical analyses of radiofrequency (RF) fields for MRI, RF power is often permitted to radiate out of the problem region. In reality, RF power will be confined by the magnet bore and RF screen enclosing the magnet room. We present numerical calculations at different frequencies for various surface and volume coil...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24244

    authors: Liu W,Kao CP,Collins CM,Smith MB,Yang QX

    更新日期:2013-01-01 00:00:00

  • Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure.

    abstract:PURPOSE:To facilitate assessment of RF power deposition and temperature rise within the breast, we present a method to seamlessly join heterogeneous breast models with standard whole-body models and demonstrate simulations at 7 T. METHODS:Finite-difference time-domain electromagnetic and bioheat simulations are perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27395

    authors: Li X,Rispoli JV

    更新日期:2019-02-01 00:00:00

  • Dynamic changes in water ADC, energy metabolism, extracellular space volume, and tortuosity in neonatal rat brain during global ischemia.

    abstract::To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac arrest using 1H MRS/...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360110

    authors: van der Toorn A,Syková E,Dijkhuizen RM,Vorísek I,Vargová L,Skobisová E,van Lookeren Campagne M,Reese T,Nicolay K

    更新日期:1996-07-01 00:00:00

  • Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain.

    abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10204

    authors: Papadakis NG,Martin KM,Mustafa MH,Wilkinson ID,Griffiths PD,Huang CL,Woodruff PW

    更新日期:2002-08-01 00:00:00

  • Bayesian inference of hemodynamic changes in functional arterial spin labeling data.

    abstract::The study of brain function using MRI relies on acquisition techniques that are sensitive to different aspects of the hemodynamic response contiguous to areas of neuronal activity. For this purpose different contrasts such as arterial spin labeling (ASL) and blood oxygenation level dependent (BOLD) functional MRI tech...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21039

    authors: Woolrich MW,Chiarelli P,Gallichan D,Perthen J,Liu TT

    更新日期:2006-10-01 00:00:00

  • GlucoCEST imaging with on-resonance variable delay multiple pulse (onVDMP) MRI.

    abstract:PURPOSE:To examine the detection sensitivity for the rapidly exchanging hydroxyl protons of D-glucose using the recently developed on-resonance variable delay multi-pulse (onVDMP) chemical exchange saturation transfer (CEST) technique. METHODS:The onVDMP method was applied for the detection of water signal changes upo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27364

    authors: Xu X,Xu J,Chan KWY,Liu J,Liu H,Li Y,Chen L,Liu G,van Zijl PCM

    更新日期:2019-01-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00