Quantitative susceptibility mapping using single-shot echo-planar imaging.

Abstract:

PURPOSE:To perform quantitative susceptibility mapping (QSM) in negligible acquisition time and apply it to measuring iron-rich subcortical gray matter. METHODS:Whole brain QSM was performed using single-shot gradient echo-planar imaging (EPI) in under 7 seconds on a standard 1.5 T system for imaging brain iron in subcortical gray matter. The method was compared to a standard 6-minute gradient recalled echo (GRE) QSM acquisition in healthy subjects. Region-of-interest QSM measurements were compared between methods in six subcortical gray-matter nuclei and two white matter territories. RESULTS:EPI-QSM provided similar mean susceptibility values to standard GRE-QSM in iron-rich subcortical gray matter regions, while providing greater than 50-fold scan time reduction. Blurring from the low spatial resolution and transverse relaxation decay of EPI affected edges but had negligible effect on whole subcortical nuclei measurements, which had a high correlation (R(2)  = 0.96) to estimated iron content. CONCLUSION:EPI-QSM can be performed in several seconds, which enables expansion of brain iron studies of subcortical gray matter to cases where time is limited and to existing MRI studies that already uses gradient echo EPI.

journal_name

Magn Reson Med

authors

Sun H,Wilman AH

doi

10.1002/mrm.25316

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

1932-8

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

73

pub_type

杂志文章
  • On the application of ultra-fast RARE experiments.

    abstract::The ultra-fast application of the RARE experiment is described in detail, with special emphasis on its multifarious applications with preparation experiments that produce transverse magnetization. The factors affecting the temporal evolution of the magnetization during the experiment are described, and the implication...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270114

    authors: Norris DG,Börnert P,Reese T,Leibfritz D

    更新日期:1992-09-01 00:00:00

  • Simultaneous measurement of intracellular and extracellular oxygen concentrations using a nitroxide-liposome system.

    abstract::The concentration of oxygen within cells is important in many physiological and pathological processes, but such oxygen-dependent phenomena are generally studied as a function of the concentration of extracellular oxygen, due to a lack of suitable methods. Electron parmamagnetic resonance (EPR) oximetric techniques of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290105

    authors: Glockner JF,Norby SW,Swartz HM

    更新日期:1993-01-01 00:00:00

  • Rapid and motion-robust volume coverage using cross-sectional real-time MRI.

    abstract:PURPOSE:To develop a rapid and motion-robust technique for volumetric MRI, which is based on cross-sectional real-time MRI acquisitions with automatic advancement of the slice position. METHODS:Real-time MRI with a frame-by-frame moving cross-section is performed with use of highly undersampled radial gradient-echo se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28029

    authors: Voit D,Kalentev O,van Zalk M,Joseph AA,Frahm J

    更新日期:2020-05-01 00:00:00

  • Predicting RF field penetration in heterogeneous bodies using a 3-D finite element approach: preliminary results.

    abstract::We present preliminary results for a 3D finite element calculation to evaluate RF penetration in conducting dielectric materials at high field strengths. A tetrahedral mesh is used along with a Coulomb gauge constraint in a finite element method that yields excellent numerical stability at high frequencies. Accuracy i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300315

    authors: Petropoulos LS,Haacke EM,Brown RW,Boerner E

    更新日期:1993-09-01 00:00:00

  • Robust abdominal imaging with incomplete breath-holds.

    abstract:PURPOSE:Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24829

    authors: Gdaniec N,Eggers H,Börnert P,Doneva M,Mertins A

    更新日期:2014-05-01 00:00:00

  • Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

    abstract::Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppress...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300511

    authors: Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

    更新日期:1993-11-01 00:00:00

  • Diffusion/perfusion MR imaging of acute cerebral ischemia.

    abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190220

    authors: Kucharczyk J,Mintorovitch J,Asgari HS,Moseley M

    更新日期:1991-06-01 00:00:00

  • Inability to directly detect magnetic field changes associated with neuronal activity.

    abstract::The ability to directly detect neuronal magnetic fields by MRI would help investigators achieve the "holy grail" of neuroimaging, namely both high spatial and temporal resolution. Both positive and negative findings have been reported in the literature, with no clear consensus as to the feasibility of direct detection...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21129

    authors: Parkes LM,de Lange FP,Fries P,Toni I,Norris DG

    更新日期:2007-02-01 00:00:00

  • SAR comparison between CASL and pCASL at high magnetic field and evaluation of the benefit of a dedicated labeling coil.

    abstract:PURPOSE:To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS:Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27931

    authors: Hirschler L,Collomb N,Voiron J,Köhler S,Barbier EL,Warnking JM

    更新日期:2020-01-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Effects of acute normovolemic hemodilution on T2*-weighted images of rat brain.

    abstract::Acute normovolemic hemodilution (HD) was induced in anesthetized rats to assess the effect of changes in hematocrit (Hct) on signal intensity in T2*-weighted magnetic resonance (MR) images. Other relevant physiological parameters were maintained invariant. Two degrees of HD were induced: mild (Hct reduced from 42.6+/-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400611

    authors: Lin W,Paczynski RP,Celik A,Hsu CY,Powers WJ

    更新日期:1998-12-01 00:00:00

  • Dynamic field map estimation using a spiral-in/spiral-out acquisition.

    abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20079

    authors: Sutton BP,Noll DC,Fessler JA

    更新日期:2004-06-01 00:00:00

  • "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

    abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22696

    authors: Hamilton LH,Fabregat JA,Moratal D,Ramamurthy S,Lerakis S,Parks WJ,Sallee D 3rd,Brummer ME

    更新日期:2011-04-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • Localized imaging using stimulated echoes.

    abstract::Stimulated-echo localized spectroscopy was combined with phase- and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can be readily applie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050412

    authors: Mills P,Chew W,Litt L,Moseley M

    更新日期:1987-10-01 00:00:00

  • NMR dispersion investigations of enzymatically degraded bovine articular cartilage.

    abstract:PURPOSE:Cross-relaxation of protons with (14) N nuclei in proteins enhances relaxivity in the quadrupolar dip range of typically 2-3 MHz Larmor frequency. The magnitude of these dips was suggested as a means of assessing the degeneracy of articular cartilage during osteoarthritis (OA). However, so far only proteoglycan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25292

    authors: Rössler E,Mattea C,Stapf S

    更新日期:2015-05-01 00:00:00

  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • Experimental approaches to image localized human 31P NMR spectroscopy.

    abstract::Experimental procedures for obtaining localized 31P NMR spectra of humans by means of the ISIS sequence are discussed in detail. The technique is optimized for use with volume coils and with surface coils in order to measure localized 31P NMR spectra of different tissues and organs. Selective frequency-modulated (FM) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110102

    authors: Luyten PR,Groen JP,Vermeulen JW,den Hollander JA

    更新日期:1989-07-01 00:00:00

  • Simultaneous quantitative mapping of conductivity and susceptibility using a double-echo ultrashort echo time sequence: Example using a hematoma evolution study.

    abstract:PURPOSE:The primary purpose of this study is to propose a method for the simultaneous quantitative three-dimensional (3D) mapping of conductivity and susceptibility using double-echo ultrashort echo time (UTE) imaging. The secondary purpose is to investigate the changes of these properties over time during in vitro hem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25869

    authors: Gho SM,Shin J,Kim MO,Kim DH

    更新日期:2016-07-01 00:00:00

  • Characterization of white matter alterations in phenylketonuria by magnetic resonance relaxometry and diffusion tensor imaging.

    abstract::A multimodal MR study including relaxometry, diffusion tensor imaging (DTI), and MR spectroscopy was performed on patients with classical phenylketonuria (PKU) and matched controls, to improve our understanding of white matter (WM) lesions. Relaxometry yields information on myelin loss or malformation and may substant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21422

    authors: Vermathen P,Robert-Tissot L,Pietz J,Lutz T,Boesch C,Kreis R

    更新日期:2007-12-01 00:00:00

  • Measurement of fibrin concentration by fast field-cycling NMR.

    abstract::The relaxation of (1)H nuclei due to their interaction with quadrupolar (14)N nuclei in gel structures is measured using fast field-cycling NMR. This phenomenon called quadrupolar dips has been reported in different (1)H-(14)N bond-rich species. In this study, we have studied quadrupolar dips in fibrin, an insoluble p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23117

    authors: Broche LM,Ismail SR,Booth NA,Lurie DJ

    更新日期:2012-05-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00

  • Safety of gadolinium-DTPA: extended clinical experience.

    abstract::This review reports data on the general and renal tolerance of the paramagnetic contrast agent Gd-DTPA after intravenous administration. Gd-DTPA was administered usually at a dose level of 0.1-0.2 mmol/kg body wt (range: 0.005-0.25 mmol/kg body wt) in cranial, spinal and body MR indications. In phase I-IIIa studies a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910220212

    authors: Niendorf HP,Haustein J,Cornelius I,Alhassan A,Clauss W

    更新日期:1991-12-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Triple diffusion encoding MRI predicts intra-axonal and extra-axonal diffusion tensors in white matter.

    abstract:PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28084

    authors: Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JH

    更新日期:2020-06-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00