Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

Abstract:

:Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppression conditions and two signal-to-noise ratio maximization procedures. Four of these matched filters correspond to previously described methods: the subtractive matched filter, the standard deviation, the global venous eigenimage and the global arterial eigenimage. The two others are referred to here as the local venous eigenimage and the local arterial eigenimage. These six matched filters have been applied to 2D time-resolved phase contrast angiographic data. The local arterial eigenimage is found to be the most effective in suppressing undesired venous flow and preserving desired arterial flow.

journal_name

Magn Reson Med

authors

Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

doi

10.1002/mrm.1910300511

subject

Has Abstract

pub_date

1993-11-01 00:00:00

pages

600-8

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

30

pub_type

杂志文章
  • Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters.

    abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25351

    authors: Collier Q,Veraart J,Jeurissen B,den Dekker AJ,Sijbers J

    更新日期:2015-06-01 00:00:00

  • Uniform spinning sampling gradient electron paramagnetic resonance imaging.

    abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24712

    authors: Johnson DH,Ahmad R,Liu Y,Chen Z,Samouilov A,Zweier JL

    更新日期:2014-02-01 00:00:00

  • Tumor 31P NMR pH measurements in vivo: a comparison of inorganic phosphate and intracellular 2-deoxyglucose-6-phosphate as pHnmr indicators in murine radiation-induced fibrosarcoma-1.

    abstract::Uncertainty regarding the intracellular/extracellular distribution of inorganic phosphate (P(i)) in tumors has raised concerns that pH calculated from the tumor P(i) chemical shift may not accurately represent the intracellular pH (pHin). This issue was addressed in subcutaneously transplanted murine radiation induced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360508

    authors: Soto GE,Zhu Z,Evelhoch JL,Ackerman JJ

    更新日期:1996-11-01 00:00:00

  • Contrast-enhanced MRI of brown adipose tissue after pharmacological stimulation.

    abstract::A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20851

    authors: Sbarbati A,Cavallini I,Marzola P,Nicolato E,Osculati F

    更新日期:2006-04-01 00:00:00

  • An analytic expression for the ultimate intrinsic SNR in a uniform sphere.

    abstract:PURPOSE:The ultimate intrinsic signal-to-noise ratio (UISNR) is normally calculated using electrodynamic simulations with a complete basis of modes. Here, we provide an exact solution for the UISNR at the center of a dielectric sphere and assess how accurately this solution approximates UISNR away from the center. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27207

    authors: Lee HH,Sodickson DK,Lattanzi R

    更新日期:2018-11-01 00:00:00

  • Measurement of 129Xe gas apparent diffusion coefficient anisotropy in an elastase-instilled rat model of emphysema.

    abstract::Hyperpolarized noble gas ((3)He and (129)Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (Δ), and (3)He ADC has been show...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24224

    authors: Boudreau M,Xu X,Santyr GE

    更新日期:2013-01-01 00:00:00

  • Comparison of k-space sampling schemes for multidimensional MR spectroscopic imaging.

    abstract::For clinical 31P MR spectroscopic imaging (MRSI) studies, where signal averaging is necessary, some improvement of sensitivity and spatial response function may be achieved by acquiring data over a spherical k-space volume and varying the number of averages acquired in proportion to the desired spatial filter. Eight d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360321

    authors: Hugg JW,Maudsley AA,Weiner MW,Matson GB

    更新日期:1996-09-01 00:00:00

  • Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

    abstract:PURPOSE:Cardiac stimulation (CS) limits to gradient coil switching speed are difficult to measure in humans; instead, current regulatory guidelines (IEC 60601-2-33) are based on animal experiments and electric field-to-dB/dt conversion factors computed for a simple, homogeneous body model. We propose improvement to thi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28472

    authors: Klein V,Davids M,Schad LR,Wald LL,Guérin B

    更新日期:2021-02-01 00:00:00

  • Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

    abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25785

    authors: Xie Y,Yang Q,Xie G,Pang J,Fan Z,Li D

    更新日期:2016-06-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Metabolic changes in activated T cells: an NMR study of human peripheral blood lymphocytes.

    abstract::Using NMR spectroscopy, we studied purified, human T lymphocytes in a serum-free medium. Purified cells were entrapped inside agarose beads and induced to proliferate by the mitogens phorbol-12-myristate-13-acetate and ionomycin. T lymphocytes in standard culture and inside agarose beads exhibit comparable viability, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290307

    authors: Bental M,Deutsch C

    更新日期:1993-03-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • Generalization of intravoxel incoherent motion model by introducing the notion of continuous pseudodiffusion variable.

    abstract:PURPOSE:A generalized intravoxel incoherent motion (IVIM) model, called the GIVIM, was proposed to better account for complex perfusion present in the tissues having various vessels and flow regimes, such as the liver. THEORY AND METHODS:The notions of continuous pseudodiffusion variable as well as perfusion fraction ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26064

    authors: Kuai ZX,Liu WY,Zhang YL,Zhu YM

    更新日期:2016-11-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • Super-resolution for upper abdominal MRI: Acquisition and post-processing protocol optimization using brain MRI control data and expert reader validation.

    abstract:PURPOSE:Magnetic resonance (MR) cholangiopancreatography (MRCP) is an established specialist method for imaging the upper abdomen and biliary/pancreatic ducts. Due to limitations of either MR image contrast or low through-plane resolution, patients may require further evaluation with contrast-enhanced computed tomograp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27852

    authors: Ebner M,Patel PA,Atkinson D,Caselton L,Firmin L,Amin Z,Bainbridge A,De Coppi P,Taylor SA,Ourselin S,Chouhan MD,Vercauteren T

    更新日期:2019-11-01 00:00:00

  • Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

    abstract:PURPOSE:To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS:A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image si...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24958

    authors: Chen D,Sharif B,Dharmakumar R,Thomson LE,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-09-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • A magnetic shield for large-bore, high field magnets.

    abstract::An effective shield for the dc fringing fields produced by a large-bore, high field magnet intended for imaging and in vivo spectroscopy is presented. While limiting the extent of fringe fields, the shield has little effect on the homogeneity of the central field of the magnet. The effect of institutional safety polic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020506

    authors: Ewing JR,Timms W,Williams JE,Welch KM

    更新日期:1985-10-01 00:00:00

  • 3D single-shot VASO using a Maxwell gradient compensated GRASE sequence.

    abstract::The vascular space occupancy (VASO) method was recently proposed as a functional MRI (fMRI) method that is capable of detecting activation-related changes in blood volume (CBV), without the need for a blood-pool contrast agent. In the present work we introduce a new whole-brain VASO technique that is based on a parall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22000

    authors: Poser BA,Norris DG

    更新日期:2009-07-01 00:00:00

  • Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

    abstract::A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arteria...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10733

    authors: Hernandez-Garcia L,Lee GR,Vazquez AL,Noll DC

    更新日期:2004-03-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

    abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20848

    authors: Sabati M,Lauzon ML,Mahallati H,Frayne R

    更新日期:2006-05-01 00:00:00

  • Measurement of perfusion and permeability from dynamic contrast-enhanced MRI in normal and pathological vertebral bone marrow.

    abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22415

    authors: Biffar A,Sourbron S,Schmidt G,Ingrisch M,Dietrich O,Reiser MF,Baur-Melnyk A

    更新日期:2010-07-01 00:00:00

  • Direct comparison of in vivo versus postmortem second-order motion-compensated cardiac diffusion tensor imaging.

    abstract:PURPOSE:To directly compare in vivo versus postmortem second-order motion-compensated spin-echo diffusion tensor imaging of the porcine heart. METHODS:Second-order motion-compensated spin-echo cardiac diffusion tensor imaging was performed during systolic contraction in vivo and repeated upon cardiac arrest by bariumc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26871

    authors: Stoeck CT,von Deuster C,Fleischmann T,Lipiski M,Cesarovic N,Kozerke S

    更新日期:2018-04-01 00:00:00

  • Editing through multiple bonds: threonine detection.

    abstract::In in vivo (1)H spectroscopy, the signal at 1.32 ppm is usually assigned to lactate. This resonance position is shared with threonine at physiological pH. The similarity of spectral patterns of lactate and threonine renders the separate measurement of either threonine or lactate without and even with editing technical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21492

    authors: Marjanska M,Henry PG,Uğurbil K,Gruetter R

    更新日期:2008-02-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Cerebrospinal fluid pulse wave velocity measurements: In vitro and in vivo evaluation of a novel multiband cine phase-contrast MRI sequence.

    abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28430

    authors: Sonnabend K,Brinker G,Maintz D,Bunck AC,Weiss K

    更新日期:2021-01-01 00:00:00

  • Characterization of aortic root atherosclerosis in ApoE knockout mice: high-resolution in vivo and ex vivo MRM with histological correlation.

    abstract::In vivo, cardiac-gated, black-blood, and ex vivo magnetic resonance microscopy (MRM) images of the aortic root, and histopathology data were obtained from 12 transgenic and wild-type (WT) mice. MRM was performed using a black-blood imaging spin-echo sequence with upstream and downstream in-flow saturation pulses to ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10360

    authors: Itskovich VV,Choudhury RP,Aguinaldo JG,Fallon JT,Omerhodzic S,Fisher EA,Fayad ZA

    更新日期:2003-02-01 00:00:00

  • Synchronous MRI of muscle motion induced by electrical stimulation.

    abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26154

    authors: Deligianni X,Pansini M,Garcia M,Hirschmann A,Schmidt-Trucksäss A,Bieri O,Santini F

    更新日期:2017-02-01 00:00:00

  • Maximum entropy and 2DFT NMR images.

    abstract::A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080310

    authors: De Simone BC,De Luca F,Maraviglia B

    更新日期:1988-11-01 00:00:00