An analytic expression for the ultimate intrinsic SNR in a uniform sphere.

Abstract:

PURPOSE:The ultimate intrinsic signal-to-noise ratio (UISNR) is normally calculated using electrodynamic simulations with a complete basis of modes. Here, we provide an exact solution for the UISNR at the center of a dielectric sphere and assess how accurately this solution approximates UISNR away from the center. METHODS:We performed a mode analysis to determine which modes contribute to central UISNR - ζ(r→0). We then derived an analytic expression to calculate ζ(r→0) and analyzed its dependence on main magnetic field strength, sample geometry, and electrical properties. We validated the proposed solution against an established method based on dyadic Green's function simulations. RESULTS:Only one divergence-free mode contributes to ζ(r→0). The UISNR given by the exact solution matched the full simulation results for various parameter settings, whereas calculation speed was approximately 1000 times faster. We showed that the analytic expression can approximate the UISNR with <5% error at positions as much as 10-20% of the radius away from the center. CONCLUSION:The proposed formula enables rapid and direct calculation of UISNR in the central region of a sphere. The resulting UISNR value may be used, for example, as an absolute reference to assess the performance of head coils with spherical phantoms.

journal_name

Magn Reson Med

authors

Lee HH,Sodickson DK,Lattanzi R

doi

10.1002/mrm.27207

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

2256-2266

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

80

pub_type

杂志文章
  • NMR relaxometric investigation on human methemoglobin and fluoromethemoglobin. An improved quantitative in vitro assay of human methemoglobin.

    abstract::Longitudinal water proton relaxation rates of methemoglobin solutions show a strong dependence on temperature and pH. The increase of the relaxation rates with temperature is associated with shortened exchange lifetime of the coordinated water molecule. An accurate measurement of the relaxation rate of methemoglobin s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330613

    authors: Aime S,Fasano M,Paoletti S,Arnelli A,Ascenzi P

    更新日期:1995-06-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

    abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22737

    authors: Wang W,Nguyen NM,Yablonskiy DA,Sukstanskii AL,Osmanagic E,Atkinson JJ,Conradi MS,Woods JC

    更新日期:2011-03-01 00:00:00

  • Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity.

    abstract::A methodology is presented for estimating T(1) using a two-point technique with a standard multislice gradient echo sequence. The method explicitly corrects for the shape of the RF pulse and for spatial variations in transmitted RF field intensity. Including these factors in the calculation of T(1) gives a substantial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1112

    authors: Parker GJ,Barker GJ,Tofts PS

    更新日期:2001-05-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Improved sampling of myocardial motion with variable separation tagging.

    abstract::A novel tagging method is introduced that increases the spatial resolution of estimates of myocardial radial thickening. The separation of adjacent parallel tag planes is customized to match the expected motion of specific regions of the heart wall. In regions in which the tags increase their separation over systole (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390421

    authors: McVeigh ER,Bolster BD Jr

    更新日期:1998-04-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

    abstract:PURPOSE:The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 imperfections, which are two main factors that affect quantitative results in MRF. METHODS:The SP and B1 imperfections are characterized and correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26580

    authors: Ma D,Coppo S,Chen Y,McGivney DF,Jiang Y,Pahwa S,Gulani V,Griswold MA

    更新日期:2017-11-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Application of image registration to measurement of intervertebral rotation in the lumbar spine.

    abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10319

    authors: Rogers BP,Haughton VM,Arfanakis K,Meyerand ME

    更新日期:2002-12-01 00:00:00

  • Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

    abstract::Developing a method to noninvasively monitor tissue-engineered constructs is critical for the optimization of construct design and for assessing therapeutic efficacy. For this purpose, NMR is a powerful technique that can be used to obtain both images and spectroscopic data. But the inherent sensitivity of NMR limits ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22268

    authors: Volland NA,Mareci TH,Constantinidis I,Simpson NE

    更新日期:2010-04-01 00:00:00

  • Inductively coupled Helmholtz coil on a dedicated imaging platform for the in vivo 1H-MRS measurement of intramyocellular lipids in the hind leg of rats.

    abstract::Skeletal muscle triglycerides are markers for insulin resistance in type 2 diabetes. Recently, MR spectroscopy was adapted for in vivo measurement of triglycerides in animal models and for the characterization of new therapeutic approaches. Because of small MR spectroscopy voxel sizes used in skeletal muscles, surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22149

    authors: Neumaier M,Niessen HG,Kaulisch T,Stiller D

    更新日期:2009-10-01 00:00:00

  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts.

    abstract::Leakage of Gd-DTPA through a defective blood-brain barrier is measured quantitatively using dynamic MRI scanning, in which repeated scans are made after a bolus injection. Image registration artifacts are minimized; a dose of 0.1 mM/kg and an IR sequence enable enhancement to be measured quantitatively. The triexponen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170208

    authors: Tofts PS,Kermode AG

    更新日期:1991-02-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

    abstract::This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24362

    authors: Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

    更新日期:2013-05-01 00:00:00

  • Dynamic glucose-enhanced (DGE) MRI in the human brain at 7 T with reduced motion-induced artifacts based on quantitative R1ρ mapping.

    abstract:PURPOSE:Dynamic glucose-enhanced (DGE)-MRI based on chemical exchange-sensitive MRI, that is, glucoCEST and gluco-chemical exchange-sensitive spin-lock (glucoCESL), is intrinsically prone to motion-induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28112

    authors: Boyd PS,Breitling J,Zimmermann F,Korzowski A,Zaiss M,Schuenke P,Weinfurtner N,Schlemmer HP,Ladd ME,Bachert P,Paech D,Goerke S

    更新日期:2020-07-01 00:00:00

  • Sensitivity of MR diffusion measurements to variations in intracellular structure: effects of nuclear size.

    abstract::Magnetic resonance imaging measurements of the apparent rate of water diffusion in tumors are sensitive to variations in tissue cellularity, which have been shown useful for characterizing tumors and their responses to treatments. However, because of technical limitations on most MRI systems, conventional pulse gradie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21793

    authors: Xu J,Does MD,Gore JC

    更新日期:2009-04-01 00:00:00

  • On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments.

    abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290510

    authors: Neil JJ,Bretthorst GL

    更新日期:1993-05-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans.

    abstract:PURPOSE:To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored. METHODS:Six healthy volunteers were scanned with...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27765

    authors: Zanette B,Santyr G

    更新日期:2019-09-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • Efficient sample density estimation by combining gridding and an optimized kernel.

    abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23041

    authors: Zwart NR,Johnson KO,Pipe JG

    更新日期:2012-03-01 00:00:00

  • Fat-water separation based on Transition REgion Extraction (TREE).

    abstract:PURPOSE:To develop a method based on fat-water transition region extraction (TREE) for robust fat-water separation and quantification in challenging scenarios, including low signal-to-noise ratio (SNR), fast changing B0 field, and disjointed anatomies. THEORY AND METHODS:In TREE method, the phasor solutions of each pi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27710

    authors: Peng H,Zou C,Cheng C,Tie C,Qiao Y,Wan Q,Lv J,He Q,Liang D,Liu X,Liu W,Zheng H

    更新日期:2019-07-01 00:00:00

  • Functional imaging with FENSI: flow-enhanced signal intensity.

    abstract::Flow measurement methods for functional MRI (fMRI) are desirable as they are more closely tied to neuronal activity than the commonly used blood oxygenation techniques. In this work we introduce a flow-based functional imaging method. The method, called flow enhancement of signal intensity (FENSI), is an extension of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21325

    authors: Sutton BP,Ouyang C,Ching BL,Ciobanu L

    更新日期:2007-08-01 00:00:00

  • Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

    abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28139

    authors: Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

    更新日期:2020-08-01 00:00:00

  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00

  • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

    abstract::Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21728

    authors: Robson PM,Grant AK,Madhuranthakam AJ,Lattanzi R,Sodickson DK,McKenzie CA

    更新日期:2008-10-01 00:00:00