Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

Abstract:

:This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load acceptance phase of gait. Volumetric images were continuously acquired for 5 min using a 3D cine spoiled gradient-echo sequence in conjunction with vastly under-sampled isotropic projection reconstruction. Knee angle was simultaneously monitored and used retrospectively to sort images into 60 frames over the motion cycle. High-resolution static knee images were acquired and segmented to create subject-specific models of the femur and tibia. At each time frame, bone positions and orientations were determined by automatically registering the skeletal models to the dynamic images. Three-dimensional tibiofemoral translations and rotations were consistent across healthy subjects. Internal tibia rotations of 7.8±3.5° were present with 35.8±3.8° of knee flexion, a pattern consistent with knee kinematic measures during walking. We conclude that vastly under-sampled isotropic projection reconstruction imaging is a promising approach for noninvasively measuring 3D joint kinematics, which may be useful for assessing cartilage contact and investigating the causes and treatment of joint abnormalities.

journal_name

Magn Reson Med

authors

Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

doi

10.1002/mrm.24362

subject

Has Abstract

pub_date

2013-05-01 00:00:00

pages

1310-6

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

69

pub_type

杂志文章
  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • Integrated volume-selective/spectral editing 1H NMR and postdetection signal processing for the sensitive determination of lactate.

    abstract::A new volume selection/spectral editing pulse sequence (VOSING) is presented. The features specific to the technique are that the volume selection and the editing intervals coincide and that no decoupling is necessary. The pulse sequence can be applied under both homo- and heteronuclear conditions. Phantom experiments...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080108

    authors: Knüttel A,Rommel E,Clausen M,Kimmich R

    更新日期:1988-09-01 00:00:00

  • MRI visualization of rodent liver structure and peritoneal adhesion with dialyzate enhancement.

    abstract::This study investigated the use of peritoneal dialysis fluid (dialyzate) as a MR contrast agent to visualize the liver structure and peritoneal adhesion in rats at 7 T. Intraperitoneal injection of dialyzate (approximately 0.1 ml/g) yielded excellent and consistent intraperitoneal enhancement that delineated the liver...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21506

    authors: Cheung JS,Guo H,Leung JC,Man K,Lai KN,Wu EX

    更新日期:2008-05-01 00:00:00

  • Perfusion mapping with multiecho multishot parallel imaging EPI.

    abstract::Echo-planar imaging (EPI) is the standard technique for dynamic susceptibility-contrast (DSC) perfusion MRI. However, EPI suffers from well-known geometric distortions, which can be reduced by increasing the k-space phase velocity. Moreover, the long echo times (TEs) used in DSC lead to signal saturation of the arteri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21255

    authors: Newbould RD,Skare ST,Jochimsen TH,Alley MT,Moseley ME,Albers GW,Bammer R

    更新日期:2007-07-01 00:00:00

  • Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

    abstract:PURPOSE:To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully sampled data sets. METHODS:Self-supervised learning via data undersampling (SSDU) for physics-guided deep learning reconstruction partitions available measurements into two disjoint sets, one of wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28378

    authors: Yaman B,Hosseini SAH,Moeller S,Ellermann J,Uğurbil K,Akçakaya M

    更新日期:2020-12-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: dose-dependent and temporal evolution of T1 contrast.

    abstract::Manganese is a useful contrast agent for MRI of animals. Previously, it has been shown that systemic doses of MnCl(2) provide unique contrast in the rodent brain, enabling visualization of neuroarchitecture. The present work investigates the dose and temporal dependence of brain enhancement after i.v. administration o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20368

    authors: Lee JH,Silva AC,Merkle H,Koretsky AP

    更新日期:2005-03-01 00:00:00

  • Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.

    abstract:PURPOSE:Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP recon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27030

    authors: Benkert T,Tian Y,Huang C,DiBella EVR,Chandarana H,Feng L

    更新日期:2018-07-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries.

    abstract::Three-dimensional magnetization-prepared (MP) MR angiography (MRA) was applied to the carotid and vertebral arteries by using ECG triggering, a slab selective RF inversion pulse, centric phase encoding and acquisition during diastole. Both theoretically and experimentally, the MP MRA sequence was shown to perform well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370219

    authors: Wilman AH,Huston J 3rd,Riederer SJ

    更新日期:1997-02-01 00:00:00

  • Generalization of intravoxel incoherent motion model by introducing the notion of continuous pseudodiffusion variable.

    abstract:PURPOSE:A generalized intravoxel incoherent motion (IVIM) model, called the GIVIM, was proposed to better account for complex perfusion present in the tissues having various vessels and flow regimes, such as the liver. THEORY AND METHODS:The notions of continuous pseudodiffusion variable as well as perfusion fraction ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26064

    authors: Kuai ZX,Liu WY,Zhang YL,Zhu YM

    更新日期:2016-11-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • Three-dimensional water/fat separation and T2* estimation based on whole-image optimization--application in breathhold liver imaging at 1.5 T.

    abstract::The chemical shift of water and fat resonances in proton MRI allows separation of water and fat signal from chemical shift encoded data. This work describes an automatic method that produces separate water and fat images as well as quantitative maps of fat signal fraction and T2* from complex multiecho gradient-recall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23185

    authors: Berglund J,Kullberg J

    更新日期:2012-06-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Nuclear relaxation of human brain gray and white matter: analysis of field dependence and implications for MRI.

    abstract::The dependence of 1/T1 on the magnetic field strength (the relaxation dispersion) has been measured at 37 degrees C on autopsy samples of human brain gray and white matter at field strengths corresponding to proton Larmor frequencies between 10 kHz and 50 MHz (0.0002-1.2 T). Additional measurements of 1/T1 and 1/T2 ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160212

    authors: Fischer HW,Rinck PA,Van Haverbeke Y,Muller RN

    更新日期:1990-11-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

    abstract::This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20866

    authors: Herold V,Mörchel P,Faber C,Rommel E,Haase A,Jakob PM

    更新日期:2006-05-01 00:00:00

  • Real-time cardiovascular MR with spatio-temporal artifact suppression using deep learning-proof of concept in congenital heart disease.

    abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27480

    authors: Hauptmann A,Arridge S,Lucka F,Muthurangu V,Steeden JA

    更新日期:2019-02-01 00:00:00

  • Tissue characterization and assessment of preoperative chemotherapeutic response in musculoskeletal tumors by in vivo 31P magnetic resonance spectroscopy.

    abstract::This study investigates the potential of in vivo 31P magnetic resonance spectroscopy (MRS) to characterize musculoskeletal tumors and to determine preoperative levels of histological necrosis, which is an important clinical indicator of patient response. Pretherapy MRS was performed on 28 patients with large musculosk...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270204

    authors: Redmond OM,Bell E,Stack JP,Dervan PA,Carney DN,Hurson B,Ennis JT

    更新日期:1992-10-01 00:00:00

  • Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver.

    abstract:PURPOSE:To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28452

    authors: Zhao R,Hamilton G,Brittain JH,Reeder SB,Hernando D

    更新日期:2021-02-01 00:00:00

  • Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

    abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28139

    authors: Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

    更新日期:2020-08-01 00:00:00

  • Relative concentrations of proton MR visible neurochemicals in gray and white matter in human brain.

    abstract::The relative distributions of N-acetylaspartate (NAA) + N-acetylaspartylglutamate (NAAG), creatine + phosphocreatine (Cr/PCr), and choline (Cho) in the gray and white matter of human brain were determined by utilizing proton magnetic resonance spectroscopic imaging (SI). The SI data was processed using an automated sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330603

    authors: Doyle TJ,Bedell BJ,Narayana PA

    更新日期:1995-06-01 00:00:00

  • Imaging oxygen tension in liver and spleen by 19F NMR.

    abstract::19F NMR imaging of the perfluorocarbon emulsion Fluosol has been used to study regional variations in oxygen tension in rat liver and spleen. We have used the linear dependence of spin lattice relaxation rate (1/T1) on the partial oxygen pressure (pO2) of Fluosol to determine the oxygen tension in the reticuloendothel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290405

    authors: Holland SK,Kennan RP,Schaub MM,D'Angelo MJ,Gore JC

    更新日期:1993-04-01 00:00:00

  • In vivo MR elastography of the prostate gland using a transurethral actuator.

    abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22038

    authors: Chopra R,Arani A,Huang Y,Musquera M,Wachsmuth J,Bronskill M,Plewes D

    更新日期:2009-09-01 00:00:00

  • Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

    abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20221

    authors: Jochimsen TH,Norris DG,Mildner T,Möller HE

    更新日期:2004-10-01 00:00:00

  • The Rician distribution of noisy MRI data.

    abstract::The image intensity in magnetic resonance magnitude images in the presence of noise is shown to be governed by a Rician distribution. Low signal intensities (SNR < 2) are therefore biased due to the noise. It is shown how the underlying noise can be estimated from the images and a simple correction scheme is provided ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340618

    authors: Gudbjartsson H,Patz S

    更新日期:1995-12-01 00:00:00

  • Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain.

    abstract:PURPOSE:Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues by means of the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28083

    authors: Arbabi A,Kai J,Khan AR,Baron CA

    更新日期:2020-06-01 00:00:00

  • Contrast-enhanced MRI of brown adipose tissue after pharmacological stimulation.

    abstract::A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20851

    authors: Sbarbati A,Cavallini I,Marzola P,Nicolato E,Osculati F

    更新日期:2006-04-01 00:00:00

  • Assessment of exposure to MRI motion-induced fields based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.

    abstract:PURPOSE:The goal of this study was to conduct an exposure assessment for workers moving through the stray stationary field of common MRI scanners, performed according to the recent International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines, which aim at avoiding annoying sensory effects. THEORY ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26031

    authors: Zilberti L,Bottauscio O,Chiampi M

    更新日期:2016-10-01 00:00:00

  • Multinuclear NMR investigations of probe construction materials at 4.7 T.

    abstract::Since background signal from NMR probes can overwhelm the signal from a sample, the NMR analysis of plastics or machinable ceramics is a prerequisite to their use in probe implementations. The contributions from a variety of materials to proton, fluorine, and carbon NMR spectra are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130317

    authors: Babcock EE,Vaughan JT,Lesan B,Nunnally RL

    更新日期:1990-03-01 00:00:00