Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

Abstract:

:Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments to BOLD signal changes in SE echo planar imaging (EPI) are investigated. To gain a better understanding of the underlying mechanisms that cause the fMRI contrast, two experiments are presented: First, the intravascular contribution is decomposed into two fractions with different regimes of flow by means of diffusion-weighting gradient schemes which are either flow-compensated, or will maximally dephase moving spins. Second, contributions from the intra- and extravascular space are selectively suppressed by combining flow-weighting with additional refocusing pulses. The results indicate two qualitatively different components of flowing blood which contribute to the BOLD contrast and a nearly equal share in functional signal from the intra- and extravascular compartments at TE approximately 80 ms and 3 T. Combining these results, there is evidence that at least one-half of the functional signal originates from the parenchyma in SE fMRI at 3 T. The authors suggest the use of flow-compensated diffusion weighting for SE fMRI to improve the sensitivity to the parenchyma.

journal_name

Magn Reson Med

authors

Jochimsen TH,Norris DG,Mildner T,Möller HE

doi

10.1002/mrm.20221

subject

Has Abstract

pub_date

2004-10-01 00:00:00

pages

724-32

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

52

pub_type

杂志文章
  • Local specific absorption rate (SAR), global SAR, transmitter power, and excitation accuracy trade-offs in low flip-angle parallel transmit pulse design.

    abstract:PURPOSE:We propose a constrained optimization approach for designing parallel transmit (pTx) pulses satisfying all regulatory and hardware limits. We study the trade-offs between excitation accuracy, local and global specific absorption rate (SAR), and maximum and average power for small flip-angle pTx (eight channels)...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24800

    authors: Guérin B,Gebhardt M,Cauley S,Adalsteinsson E,Wald LL

    更新日期:2014-04-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • Myocardial T2* mapping free of distortion using susceptibility-weighted fast spin-echo imaging: a feasibility study at 1.5 T and 3.0 T.

    abstract::This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T2* mapping of the heart. First, T2* maps are presented for oil phantoms ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22054

    authors: Heinrichs U,Utting JF,Frauenrath T,Hezel F,Krombach GA,Hodenius MA,Kozerke S,Niendorf T

    更新日期:2009-09-01 00:00:00

  • The MR tomograph as a sound generator: fMRI tool for the investigation of the auditory cortex.

    abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400621

    authors: Bilecen D,Radü EW,Scheffler K

    更新日期:1998-12-01 00:00:00

  • Local planar gradients with order-of-magnitude strength and speed advantage.

    abstract::A three-axis uniplanar gradient coil was designed and built to provide order-of-magnitude increases in gradient strength of up to 500 mT/m on the x- and y-axes, and 1000 mT/m for the z-axis at 640 A input over a limited FOV ( approximately 16 cm) for superficial regions, compared to conventional gradient coils, with s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21263

    authors: Aksel B,Marinelli L,Collick BD,Von Morze C,Bottomley PA,Hardy CJ

    更新日期:2007-07-01 00:00:00

  • In vivo imaging of insulin-secreting human pancreatic ductal cells using MRI reporter gene technique: A feasibility study.

    abstract:PURPOSE:The purpose of this study was to investigate the feasibility of in vivo imaging of human pancreatic ductal cells by OATP1B3 reporter gene under MRI. METHODS:A human cell line (PANC-1) derived from the pancreatic ductal epithelium was used in this study. After transduction of OATP1B3, the cellular physiological...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27749

    authors: Wu MR,Hsiao JK,Liu HM,Huang YY,Tseng YJ,Chou PT,Weng TI,Yang CY

    更新日期:2019-08-01 00:00:00

  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Three-dimensional MRI with independent slab excitation and encoding.

    abstract::Three-dimensional MRI is typically performed with the same orientation for radiofrequency slab excitation and slab select phase encoding. We introduce independent slab excitation and encoding to create a new degree of freedom in three-dimensional MRI, which is the angular relationship between the prescribed excitation...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23043

    authors: Eissa A,Wilman AH

    更新日期:2012-02-01 00:00:00

  • Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26406

    authors: Küstner T,Würslin C,Schwartz M,Martirosian P,Gatidis S,Brendle C,Seith F,Schick F,Schwenzer NF,Yang B,Schmidt H

    更新日期:2017-08-01 00:00:00

  • Spin-lattice relaxation time measurements using hybrid CSI--phantom study.

    abstract::The spin-lattice relaxation time T1 of multicomponent tissues is often determined by fitting relaxation data to monoexponential functions. This process can lead to large errors in the relaxation time. We describe a procedure using chemical-shift imaging (CSI) which separates the NMR signal into water and lipid compone...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130307

    authors: Hornak JP,Smith AC,Szumowski J

    更新日期:1990-03-01 00:00:00

  • Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

    abstract:PURPOSE:MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to nonlocal effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24848

    authors: Hernando D,Cook RJ,Diamond C,Reeder SB

    更新日期:2013-09-01 00:00:00

  • Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI.

    abstract::Myocardial blood flow varies during the cardiac cycle in response to pulsatile changes in epicardial circulation and cyclical variation in myocardial tension. First-pass assessment of myocardial perfusion by dynamic contrast-enhanced MRI is one of the most challenging applications of MRI because of the spatial and tem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22538

    authors: Radjenovic A,Biglands JD,Larghat A,Ridgway JP,Ball SG,Greenwood JP,Jerosch-Herold M,Plein S

    更新日期:2010-12-01 00:00:00

  • Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27177

    authors: Fyrdahl A,Vargas Paris R,Nyrén S,Holst K,Ugander M,Lindholm P,Sigfridsson A

    更新日期:2018-11-01 00:00:00

  • Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging.

    abstract::It is well known that when compared to conventional spin-echo (CSE) imaging for equivalent effective echo times, fast spin-echo (FSE) imaging experiments yield higher signal intensities for coupled spin systems, such as that for lipid. One hypothesis put forth for this phenomenon is the removal of scalar coupling-base...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350409

    authors: Williamson DS,Mulken RV,Jakab PD,Jolesz FA

    更新日期:1996-04-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • Phase-contrast velocimetry with simultaneous fat/water separation.

    abstract::Phase-contrast MRI can provide high-resolution angiographic velocity images, especially in conjunction with non-Cartesian k-space sampling. However, acquisitions can be sensitive to errors from artifacts from main magnetic field inhomogeneities and chemical shift from fat. Particularly in body imaging, fat content can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22355

    authors: Johnson KM,Wieben O,Samsonov AA

    更新日期:2010-06-01 00:00:00

  • Pattern recognition of MRSI data shows regions of glioma growth that agree with DTI markers of brain tumor infiltration.

    abstract::Gliomas are the most common primary brain tumors and the majority are highly malignant, with one of the worst prognoses for patients. Gliomas are characterized by invasive growth into normal brain tissue that makes complete surgical resection and accurate radiotherapy planning extremely difficult. We have performed in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22163

    authors: Wright AJ,Fellows G,Byrnes TJ,Opstad KS,McIntyre DJ,Griffiths JR,Bell BA,Clark CA,Barrick TR,Howe FA

    更新日期:2009-12-01 00:00:00

  • T2 relaxation-time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms.

    abstract:PURPOSE:Multi-echo spin-echo (MSE) transverse relaxometry mapping using multi-component models is used to study disease activity in neuromuscular disease by assessing the T2 of the myocytic component (T2water ). Current extended phase graph algorithms are not optimized for fat fractions above 50% and the effects of ina...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28290

    authors: Keene KR,Beenakker JM,Hooijmans MT,Naarding KJ,Niks EH,Otto LAM,van der Pol WL,Tannemaat MR,Kan HE,Froeling M

    更新日期:2020-11-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI.

    abstract::Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal stru...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24524

    authors: Asif MS,Hamilton L,Brummer M,Romberg J

    更新日期:2013-09-01 00:00:00

  • Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

    abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25317

    authors: Hess AT,Bissell MM,Ntusi NA,Lewis AJ,Tunnicliffe EM,Greiser A,Stalder AF,Francis JM,Myerson SG,Neubauer S,Robson MD

    更新日期:2015-05-01 00:00:00

  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    abstract::In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23204

    authors: Lee J,Kim KW,Lee H,Lee SJ,Choi S,Jeong WK,Kye H,Song GW,Hwang S,Lee SG

    更新日期:2012-07-01 00:00:00

  • Suppression of physiological eye movement artifacts in functional MRI using slab presaturation.

    abstract::Reduction of image-to-image signal fluctuations and imaging artifacts is important for fMRI studies. The imaging artifacts caused by respiration, cardiac pulsation, and gross head motion and the suppression of these artifacts have been studied for many years. However, the artifacts caused by eye movement and their eff...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380407

    authors: Chen W,Zhu XH

    更新日期:1997-10-01 00:00:00

  • Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

    abstract::Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20061

    authors: Saranathan M,Rochitte CE,Foo TK

    更新日期:2004-05-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

    abstract:PURPOSE:To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). METHODS:An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27337

    authors: Boudreau M,Pike GB

    更新日期:2018-12-01 00:00:00