Semiautomated spleen volumetry with diffusion-weighted MR imaging.

Abstract:

:In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry.

journal_name

Magn Reson Med

authors

Lee J,Kim KW,Lee H,Lee SJ,Choi S,Jeong WK,Kye H,Song GW,Hwang S,Lee SG

doi

10.1002/mrm.23204

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

305-10

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

68

pub_type

杂志文章
  • MRI quantitative myocardial perfusion with compartmental analysis: a rest and stress study.

    abstract::K1 (first-order transfer constant from arterial plasma to myocardium for Gd-DTPA) and Vd (distribution volume of Gd-DTPA in myocardium) were measured in vivo in a canine model (n = 5) using MRI-derived myocardial perfusion curves and a compartmental model. Perfusion curves were obtained after a bolus injection of Gd-D...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380618

    authors: Vallée JP,Sostman HD,MacFall JR,Wheeler T,Hedlund LW,Spritzer CE,Coleman RE

    更新日期:1997-12-01 00:00:00

  • The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

    abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030509

    authors: Hoult DI,Chen CN,Sank VJ

    更新日期:1986-10-01 00:00:00

  • Online correction of respiratory-induced field disturbances for continuous MR-thermometry in the breast.

    abstract::MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21954

    authors: Hey S,Maclair G,de Senneville BD,Lepetit-Coiffe M,Berber Y,Köhler MO,Quesson B,Moonen CT,Ries M

    更新日期:2009-06-01 00:00:00

  • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

    abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10690

    authors: Bodammer N,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2004-01-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Whole-heart steady-state free precession coronary artery magnetic resonance angiography.

    abstract::Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10653

    authors: Weber OM,Martin AJ,Higgins CB

    更新日期:2003-12-01 00:00:00

  • 31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

    abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050405

    authors: Shapiro JI,Haug CE,Weil R 3rd,Chan L

    更新日期:1987-10-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

    abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26969

    authors: Deelchand DK,Auerbach EJ,Marjańska M

    更新日期:2018-06-01 00:00:00

  • Localized 7Li MR spectroscopy and spin relaxation in rat brain in vivo.

    abstract::Localized 7Li MR point-resolved spectroscopy (PRESS) was developed as a technique to measure lithium (Li) concentration in rat brain in vivo. Localized 7Li spectra could be obtained at 4.7 T in a 0.7-ml voxel in rat brain over the entire therapeutic range of serum Li for humans. Localized 7Li spin-lattice (T1) and spi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20112

    authors: Komoroski RA,Pearce JM

    更新日期:2004-07-01 00:00:00

  • Differential effect of isoflurane, medetomidine, and urethane on BOLD responses to acute levo-tetrahydropalmatine in the rat.

    abstract::Levo-tetrahydropalmatine (l-THP) has shown significant promise in preclinical and clinical studies to treat drug addiction. Pharmacological MRI methods can elucidate the regional cerebral effects of l-THP, but there are potential confounds from the use of general anesthesia. To investigate the possible anesthetic-drug...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23243

    authors: Liu X,Li R,Yang Z,Hudetz AG,Li SJ

    更新日期:2012-08-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00

  • Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart.

    abstract::Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal relaxation rate, and could t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1188

    authors: Larsson HB,Rosenbaum S,Fritz-Hansen T

    更新日期:2001-08-01 00:00:00

  • Perfusion MRI of U87 brain tumors in a mouse model.

    abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20029

    authors: Sun Y,Schmidt NO,Schmidt K,Doshi S,Rubin JB,Mulkern RV,Carroll R,Ziu M,Erkmen K,Poussaint TY,Black P,Albert M,Burstein D,Kieran MW

    更新日期:2004-05-01 00:00:00

  • T2 relaxation-time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms.

    abstract:PURPOSE:Multi-echo spin-echo (MSE) transverse relaxometry mapping using multi-component models is used to study disease activity in neuromuscular disease by assessing the T2 of the myocytic component (T2water ). Current extended phase graph algorithms are not optimized for fat fractions above 50% and the effects of ina...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28290

    authors: Keene KR,Beenakker JM,Hooijmans MT,Naarding KJ,Niks EH,Otto LAM,van der Pol WL,Tannemaat MR,Kan HE,Froeling M

    更新日期:2020-11-01 00:00:00

  • Absolute quantification of myocardial perfusion under adenosine stress.

    abstract::The prebolus technique allows one to quantify perfusion in the human heart with a low variability by means of MRI. In this study the prebolus technique was used to determine quantitative perfusion values in the human heart under adenosine stress and to measure the myocardial perfusion reserve (MPR). Twelve healthy vol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21020

    authors: Ritter C,Brackertz A,Sandstede J,Beer M,Hahn D,Köstler H

    更新日期:2006-10-01 00:00:00

  • Macromolecule mapping of the brain using ultrashort-TE acquisition and reference-based metabolite removal.

    abstract:PURPOSE:To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. METHODS:An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26896

    authors: Lam F,Li Y,Clifford B,Liang ZP

    更新日期:2018-05-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • NMR determination of myocardial pH in vivo: separation of tissue inorganic phosphate from blood 2,3-DPG.

    abstract::Phosphorus NMR can measure myocardial tissue pH from the chemical shift of inorganic phosphate (Pi) in isolated buffer-perfused hearts, but in vivo the Pi peak originating from the myocardium is obscured by the resonance of 2,3-diphosphoglycerate (DPG) in the blood, making pH difficult to determine. Taking advantage o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170209

    authors: Zahler R,Majumdar S,Frederick B,Laughlin M,Barrett E,Gore JC

    更新日期:1991-02-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Detection of liver fibrosis with magnetic cross-relaxation.

    abstract::The utility of MRI using magnetization transfer (MT) enhanced pulse sequences to diagnose hepatic cirrhosis in a rat model was investigated. Hepatic T1 was measured with and without MT off-resonance RF pulses in 17 treated and six control rats. The livers were evaluated histologically, and the hydroxyproline content q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310513

    authors: Aisen AM,Doi K,Swanson SD

    更新日期:1994-05-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Measurement of cerebral blood flow by volume-selective 19F NMR spectroscopy.

    abstract::A stimulated echo sequence was used to obtain 19F NMR spectra from within a 4-ml voxel in a cat brain. The time dependence of the 19F NMR signal from an inert gas (CHF3) was used to calculate the blood flow in the voxel. The position of the voxel was selected using a 1H MR image. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160316

    authors: van Zijl PC,Ligeti L,Sinnwell T,Alger JR,Chesnick AS,Moonen CT,McLaughlin AC

    更新日期:1990-12-01 00:00:00

  • Effect of distortion corrections on the tractography quality in spinal cord diffusion-weighted imaging.

    abstract:PURPOSE:To assess the impact of a different distortion correction (DC) method and patient geometry (sagittal balance) on the quality of spinal cord tractography rendering according to different tractography approaches. METHODS:Forty-four adults free of spinal cord diseases underwent cervical diffusion-weighted imaging...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28665

    authors: Dauleac C,Bannier E,Cotton F,Frindel C

    更新日期:2021-01-21 00:00:00

  • Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

    abstract:PURPOSE:Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26794

    authors: Williams SN,Nielsen JF,Fessler JA,Noll DC

    更新日期:2018-03-01 00:00:00

  • Anisotropy of NMR properties of tissues.

    abstract::Orientational anisotropy of T2 and T1 relaxation times, diffusion, and magnetization transfer has been investigated for six different tissues: tendon, cartilage, kidney, muscle, white matter, and optic nerve. Relaxation anisotropy was observed for tendon and cartilage, and diffusional anisotropy was measured in kidney...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320508

    authors: Henkelman RM,Stanisz GJ,Kim JK,Bronskill MJ

    更新日期:1994-11-01 00:00:00

  • Diffusion tensor imaging using single-shot SENSE-EPI.

    abstract::SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10184

    authors: Bammer R,Auer M,Keeling SL,Augustin M,Stables LA,Prokesch RW,Stollberger R,Moseley ME,Fazekas F

    更新日期:2002-07-01 00:00:00

  • In vivo MRI of fresh stored osteochondral allograft transplantation with delayed gadolinium-enhanced MRI of cartilage: protocol considerations and recommendations.

    abstract::The protocol for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) was adapted for the evaluation of transplanted osteochondral allograft cartilage. Eight patients with focal grade 4 cartilage defects of the femoral condyle were treated with single cylindrical osteochondral allografts. At 1 and 2 years, dGEMRIC i...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24419

    authors: Durkan MG,Szumowski J,Brown DS,Foss EW,Crawford DC

    更新日期:2013-06-01 00:00:00